TCL duct set: range illustration, not to scale

TCL ducted air conditioning M36D1W2 · 10.55 kW

1.434,12 €VAT included

9073 frigorías/h for ducted air conditioning. Interior height of 245 mm and single-phase power supply.

3/8″ / 5/8″ · Monofásica · body 245 mm de alto · precarga 5 m What to consider

VAT and shipping included. Installation not included. Availability and delivery time to be confirmed.

Availability to be confirmed
Components and supply

What does the TCL M36D1W2 include?

Duct set 1×1: components grouped according to the TCL table.

ModelComponentSupply scope
MN36DW2Ducted indoor unit
1200 × 245 × 700 mm · 36.0 kg
1 included
MT3612Outdoor unit
910 × 804 × 378 mm · 52 kg
1 included

Wired remote control included as per catalog; does not include wireless remote control. Control reference to be confirmed when requesting the supply. Installation, pipes, supports, wiring, ducts, and grilles, as well as commissioning, are quoted separately.

Cover: illustrative composition of the range, not to scale. The official photographs of the indoor unit are shared among capacities. Check the references and dimensions of this set.

Guide

What to check before installing TCL M36D1W2

The choice of equipment does not replace the inspection of the installation by a qualified professional.

  1. Reserve space for the interior of 245 mm in height, its connections, the drain, and the maintenance access points. The duct network and the grilles are sized separately.
  2. Tubería 3/8″ / 5/8″. Precarga para 5 m; longitud máxima equivalente 75 m y desnivel 30 m. Por encima de 5 m: 25 g/m adicionales. El instalador debe contrastar placa y revisión antes de intervenir.
  3. The set is single-phase. The installer will check the voltage of the PCB, the protections, the wiring, and the ventilation distances.
  4. Wired remote control included as per catalog; wireless remote control not included. Control reference to be confirmed when requesting the supply.
Technical data

TCL M36D1W2

Brand
TCL
Model and composition
TCL M36D1W2
Supply scope
MN36DW2 + MT3612
Installation
Not included
Availability and transport
VAT and shipping included. Installation not included. Confirm availability and delivery time.

Specifications and dimensions of the model

Capabilities, consumption, efficiency, noise, and dimensions of this pair. The testing conditions and climate are part of each value.

Set
M36D1W2
Set and power supply
Indoor unit
MN36DW2
Set and power supply
Outdoor unit
MT3612
Set and power supply
Type
Ducts 1×1 · cooling and heating
Set and power supply
Power supply
220 V · single-phase
Set and power supply
Nominal power in cold conditions
10.55 kW
Power and efficiency
Approximate nominal cooling capacity
9073 frigorías/h
Power and efficiency · Conversion: kW × 860.
Nominal heat output
11.72 kW
Power and efficiency
Energy class in cold
A++
Power and efficiency
Energy class in heating
A+
Power and efficiency
Interior · width × height × depth
1200 × 245 × 700 mm
Measures to prepare the installation
Exterior · width × height × depth
910 × 804 × 378 mm
Measures to prepare the installation
Net internal weight
36.0 kg
Measures to prepare the installation
Net external weight
52 kg
Measures to prepare the installation
Pipe · liquid / gas
3/8″ / 5/8″
Pipe and refrigerant
Refrigerant
R32
Pipe and refrigerant
Factory published load
1.70 kg
Pipe and refrigerant · Catalog data; check the revision plate provided.
SEER
6,4
Eficiencia, consumo y circulación de aire
SCOP · average climate
4,1
Eficiencia, consumo y circulación de aire
Consumo nominal en frío
3415 W
Eficiencia, consumo y circulación de aire · Potencia eléctrica nominal, no capacidad térmica.
Consumo nominal en calor
3230 W
Eficiencia, consumo y circulación de aire · Potencia eléctrica nominal, no capacidad térmica.
External sound power
67 dB(A)
Eficiencia, consumo y circulación de aire · Potencia sonora, no presión sonora.
Potencia sonora interior · S/H/M/L/silencio
57/55/53/51/49 dB(A)
Eficiencia, consumo y circulación de aire · Potencia sonora, no presión sonora.
Caudal de aire interior
1900 m³/h
Eficiencia, consumo y circulación de aire
Presión estática externa nominal
37 Pa
Eficiencia, consumo y circulación de aire
Presión estática externa regulable
0-200 Pa
Eficiencia, consumo y circulación de aire
Tubería cubierta por la precarga
5 m
Límites para preparar la instalación · Catálogo TCL 2026 Portugal, página PDF 11; no es el recorrido máximo.
Longitud máxima equivalente
75 m
Límites para preparar la instalación · Catálogo oficial TCL Italia 2026, página PDF 63. Longitud equivalente, no solo tubo recto.
Maximum slope
30 m
Límites para preparar la instalación · Entre las unidades interior y exterior.
Longitud mínima recomendada
3 m
Límites para preparar la instalación · Catálogo oficial TCL Italia 2026.
Carga adicional por encima de 5 m
25 g/m
Límites para preparar la instalación · Dentro de los límites permitidos. Confirmar placa y revisión; intervención de profesional habilitado.
Before purchasing
  • Data from the linked documentation for the indicated reference. Check the PCB and the installation manual of the supplied revision before sizing gaps, connections, or refrigerant charge. The images are not assembly diagrams.

Documentation

Frequently Asked Questions

Questions about TCL M36D1W2

How many frigorías does the TCL M36D1W2 have?
Approximately 9073 frigorías/h, based on 10.55 kW nominal in cooling. It is thermal capacity, not electrical consumption.
What does the set include?
Indoor duct unit MN36DW2, outdoor unit MT3612. Wired remote control included as per catalog; does not include wireless remote control. Control reference to be confirmed when requesting supply.
What pipe do you need?
Tubería 3/8″ / 5/8″. Precarga para 5 m; longitud máxima equivalente 75 m y desnivel 30 m. Por encima de 5 m: 25 g/m adicionales. El instalador debe contrastar placa y revisión antes de intervenir.
How much false ceiling do you need?
The body is 245 mm high. The mounting, drainage, connections, and service space must be added; that figure should not be taken as the minimum false ceiling.
Is it single-phase or three-phase?
It is single-phase. Check the voltage of the PCB and protections with the installer.
Can I buy it with installation?
The price includes VAT and shipping costs. Installation is quoted separately based on location, route, and necessary work. Check availability and lead time before placing the order.

Services for your air conditioning

TCL ducted air conditioning M36D1W2 · 10.55 kW