Chaffoteaux Isofast/Thema PCB Ref. 60000390
The control PCB of the Chaffoteaux Isofast/Thema manages the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, lock out, or exhibit erratic behavior. This model is compatible with boilers from the Niagara Delta range, such as the 30 FF model, among others. A technician must confirm through diagnosis whether it needs to be replaced if you experience these issues to restore the proper functioning of your boiler.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- Catalogue reference
- 60000390
- Warranty
- 1 year
Chaffoteaux boilers compatible with reference 60000390
PCB with reference 60000390. A proven compatibility: 30 FF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux 30 FF | Niagara Delta | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 60000390 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 60000390. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the PCB 60000390
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler shows no signs of life: no indicators, no display, no startup noise.
Cause: The PCB is not receiving power at its input or its internal power supply stage has been damaged, so no power is reaching anything.
With the boiler plugged in, use a multimeter to check that 230V are entering the PCB and check if there is a visible blown fuse before replacing it.
- 02
The display shows a different fault code each time, without corresponding to any real fault with the burner or the sensors.
Cause: The control electronics are misinterpreting the signals it receives and causing lockouts that do not correspond to the installation.
Note the codes that appear and reset; if they change without a pattern and the components they indicate are fine, the fault points to the PCB.
- 03
It turns on, runs for a while, and then stops by itself; sometimes it restarts as if you had turned it off and on again.
Cause: An intermittent fault in the PCB, such as a cold solder joint or an overheating component, causes it to momentarily lose control.
Check if the shutdown coincides with the boiler being on for a while or with hitting the casing; this indicates a loose solder joint on the PCB.
- 04
With the boiler turned off, the pump or the fan keeps running and there's no way to stop them.
Cause: A relay on the PCB has stuck and continues to send current to that output even though the control says to stop.
Disconnect the pump connector with the boiler turned off and check if there is still voltage at that point; if there is, the relay on the PCB is the culprit.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Chaffoteaux 60000390 PCB.
- Catalogue reference
- 60000390
- Uniclima internal SKU
- PLCN30FF
- Brand
- Chaffoteaux
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Transformer - secondary voltage/current 3
- 8.5V / 2.72A (pins 13-14)
- Transformer - secondary voltage/current 2
- 24.3–24.5V / 0.24–0.3A (pins 15-16); last digit unclear in the photo
- Transformer - power
- 18-19VA; ambiguous digit in the photo
- Transformer - code/batch
- COUET3 MCU 000095609900 / 0601420001963-92D0501700