Thermowatt PCB Chaffoteaux Niagara Delta 30 FF Ref. 61307041
The Thermowatt PCB for the Chaffoteaux Niagara Delta 30 FF boiler is a vital component that controls the ignition, burner modulation, pump, and safety features of the boiler. When it fails, you may notice that the boiler does not start, locks out, or behaves erratically. This part is compatible with several models in the Niagara Delta range, such as the Niagara Delta 24 CF, 24 FF, 24 VMC, and the Niagara Delta 28 CF, 28 FF. A technician must confirm through diagnosis whether it is necessary to replace the PCB when these symptoms or fault code 32, which indicates a communication defect with the main board, occur.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- Catalogue reference
- 61307041
- Warranty
- 1 year
Chaffoteaux boilers compatible with reference 61307041
PCB with reference 61307041. Six confirmed compatibilities: Niagara Delta 24 CF and Niagara Delta 24 FF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux Niagara Delta 24 CF | Niagara Delta 24 | Contrasted |
| Chaffoteaux Niagara Delta 24 FF | Niagara Delta 24 | Contrasted |
| Chaffoteaux Niagara Delta 24 VMC | Niagara Delta 24 | Contrasted |
| Chaffoteaux Niagara Delta 28 CF | Niagara Delta 28 | Contrasted |
| Chaffoteaux Niagara Delta 28 FF | Niagara Delta 28 | Contrasted |
| Chaffoteaux Niagara Delta 30 FF | Niagara Delta 30 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 61307041 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 61307041. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the PCB 61307041
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler is completely unresponsive when the switch is turned on, with no reaction at all.
Cause: The power supply stage of the PCB does not energize the rest of the control circuit.
Check the internal fuse and the arrival of 230V before replacing the PCB.
- 02
There is no ignition spark even though the fan starts normally.
Cause: The PCB does not generate the ignition order to the electrode even though the previous cycle completes successfully.
Check the wiring of the electrode and its continuity before replacing the PCB.
- 03
The ignition transformer buzzes but does not spark, and sometimes there is a burnt smell in the area of the PCB.
Cause: The transformer integrated into this PCB, along with the silkscreen, can fail without damaging the rest of the circuit.
Visually inspect the PCB for any burn marks or the smell of burnt components before replacing it entirely.
- 04
It turns off with a flame fault code as soon as it starts, even though the burner appears to be lit.
Cause: Fault in the ionization circuit of the PCB, which does not recognize the flame even when it is present.
Clean and check the flame detection electrode before declaring the PCB faulty.
- 05
The boiler takes a long time to respond when pressing the buttons or it gets "stuck" for several seconds.
Cause: The processor of the PCB is responding slowly due to an internal fault in the electronics.
Perform a complete reset (turn off, wait one minute, turn on) to rule out a temporary hang before replacing the PCB.
Chaffoteaux fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| 32 | Communication fault with the main board | This symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Chaffoteaux 61307041 PCB.
- Catalogue reference
- 61307041
- Uniclima internal SKU
- TEND30FF
- Brand
- Chaffoteaux
- Type of part
- PCBs (control boards)
- Units in stock
- 0 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Manufacturer
- Thermowatt
- Manufacturer code
- 060102920010
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Chaffoteaux Niagara Delta 28 FF Manual (PDF) Document © Chaffoteaux, provided as a technical reference.