Fagor Supercompact FE 27 E Control PCB Ref. N03G010M3

Fagor Supercompact FE 27 E Control PCB Ref. N03G010M3

40 €VAT includedIn stock · 2 units

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks up, or the display is unresponsive. Compatible with FE 27 E (ref. N03G010M3). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
N03G010M3
Brand
Fagor
Type of part
PCBs (control boards)
Available units
2 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. N03G010M3) equips these models. Verified compatibility; check the reference before purchasing.

Fagor Supercompact

  • FE 27 E

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F5Control board fault: internal fault in the electronic circuit causing the boiler to lockout.It is the code that the brand itself directly attributes to an internal fault of the main PCB (this part); it is verified by ruling out power supply and connections, and checking that the lock persists after a reset, in which case the PCB is the cause.
F10Fault in the control or closure of the gas valve (cannot be unlocked).The brand documents this fault as related to the control circuit of the O valve itself; when the gas valve is healthy, the origin is the control circuit governed by the PCB (this part). It is verified by measuring the signal/coil of the valve: if the valve responds correctly and the F10 persists, the cause is the PCB.
How do I know if this PCB is for my boiler?
Check the reference N03G010M3 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.