Main Control PCB Vaillant Ecotec Plus VMW ES 296 3 5 Ref. 0020092478

Main Control PCB Vaillant Ecotec Plus VMW ES 296 3 5 Ref. 0020092478

120 €VAT included

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks up, or the display is unresponsive. Compatible with VMW 296/3-5, VMW 296/3-5 R3, VMW 296/3-5 R5 (ref. 0020092478). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
0020092478
Brand
Vaillant
Type of part
PCBs (control boards)
Available units
0 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 0020092478) equips these models. Verified compatibility; check the reference before purchasing.

ecoTEC plus VMW (combi)

  • VMW 296/3-5
  • VMW 296/3-5 R3
  • VMW 296/3-5 R5
  • VMW 346/3-5
  • VMW 346/3-5 R3
  • VMW 346/3-5 R5

ecoTEC plus VM (heating only)

  • VM 246/3-5
  • VM 246/3-5 R3
  • VM 376/3-5
  • VM 376/3-5 R3
  • VM 376/3-5 R5

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.61Gas valve activation errorThe driver/relay of the PCB does not activate the gas valve when there is a demand. Check the voltage at the terminals of the valve during the request; if the wiring and valve are correct and no stable command is received, the PCB is defective.
F.62Gas valve disconnection delayThe output from the PCB to the valve remains stuck or leaking (relay/power stage), keeping the valve energized after shutdown. Check that the voltage to the valve drops immediately when the flame ceases; if the voltage persists and the valve closes when manually de-energized, the PCB is the cause.
F.63Fault: EEPROMCorruption/invalid reading of the EEPROM memory in the PCB. Check retry and power supply stability; if the fault persists, reprogram if applicable or replace the PCB.
F.64Electronic fault / NTCFault in the measurement circuit on the PCB interpreting a short circuit in the NTC even when correct. Check NTC resistances in the sensor and in the board connector; if readings are correct and the warning persists, the fault is in the analog input of the PCB.
F.65Fault: PCB temperatureThe PCB detects internal overtemperature or its thermal sensor is damaged. Check for external thermal influence and ventilation; if the ambient temperature is normal and the issue persists, the electronics/PCB is faulty.
F.67Fault: electronics/flameFault in the flame evaluation electronics of the PCB (implausible ionization signal). Check electrode/cable and ionization current; if they are correct and still implausible, the detection stage in the PCB is faulty.
F.70Invalid appliance code (DSN)Display and PCB have been replaced without reprogramming the DSN/coding, or the power coding of the board does not match. Check/adjust DSN in service menu and coding resistor; if not possible, install the correct PCB and parameterize.
How do I know if this PCB is for my boiler?
Verify the reference 0020092478 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.