PCB Boiler Fagor FEB24ED3 Ref. N03A001A0

PCB Boiler Fagor FEB24ED3 Ref. N03A001A0

The PCB of the Fagor FEB24ED3 boiler, reference N03A001A0, controls the ignition, burner modulation, pump, and safety features of the boiler. If it fails, the boiler will not start, may lock out, or exhibit erratic behavior, potentially displaying the fault code F5: Control board fault. This board is compatible with several models, such as the FE-24 NOX, FEB 24 AR-1 N, and FE 26 TC-1 N, among others. A technician must confirm through diagnosis whether it needs to be replaced when these symptoms or the mentioned fault code occur.

Catalogue reference
AS0007548
Warranty
1 year
VAT included Stock · 6 units
Compatibility

Fagor boilers compatible with reference AS0007548

PCB with reference AS0007548. Ten verified compatibilities: FE-24 NOX and 1 FE 24 NOX B.

Proven compatibility

Boiler modelFamilyVerification
Fagor FE-24 NOxFE 24 NOXContrasted
Fagor 1 FE 24 NOx BFE 24 NOXContrasted
Fagor 1 FE 24 NOx NFE 24 NOXContrasted
Fagor 1 FE 24 NOx-1 BFE 24 NOXContrasted
Fagor 1 FE 24 NOx-1 NFE 24 NOXContrasted
Fagor 1 FEE 24 NOx-1 BFEE 24 NOXContrasted
Fagor 1 FEE 24 NOx-1 NFEE 24 NOXContrasted
Fagor FEB 24 AR-1 BFEB 24 ARContrasted
Fagor FEB 24 AR-1 NFEB 24 ARContrasted
Fagor FE 26 TC-1 NFE 26 TCContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. AS0007548 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference AS0007548. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB AS0007548

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not start even though the thermostat is calling for heat.

    Cause: One of the OMRON G5NB-1A relays on the PCB is not switching and is not sending the command to the component it should activate.

    Check if you can hear the click of the relay when calling for heat; if neither of the two sounds, it points more towards the PCB.

  • 02

    A specific component fails to start (pump, fan, or valve) while the rest operates normally.

    Cause: Each relay on the PCB controls a different component; if only one fails, the rest continue to operate.

    Identify which exact component is not starting; if it's just one, check that component and its wiring first, not just the PCB.

  • 03

    The boiler shows an error or stops after running for a while.

    Cause: The PCB is designed to operate up to 130°C; excessive heat in the junction box can cause it to fail repeatedly.

    Check that the boiler casing ventilation is not obstructed and that the cooling fan, if it has one, is working.

  • 04

    The boiler resets itself or gives strange faults when there are other electrical appliances nearby.

    Cause: The SCHAFFNER EMI filter on the PCB protects against interference; if it is damaged, external electrical noise can seep in and cause resets.

    Try unplugging other devices on the same electrical line and check if the fault disappears before considering the PCB as faulty.

Fagor fault codes that require diagnosis

CodeFaultTechnical checks
F5PCB fault (internal fault of the electronic circuit).The main PCB (AS0007548) has an internal hardware fault or control program protections/software issue, causing the boiler's self-diagnosis to lock it. Check for the arrival of 230 V and auxiliary voltages on the board (e.g., 5 VDC), fuse/relays, and absence of shorts; if the issue persists, replace the board.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Fagor AS0007548 PCB.

Catalogue reference
AS0007548
Uniclima internal SKU
PECFEM1901
Brand
Fagor
Type of part
PCBs (control boards)
Units in stock
6 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

PCB code
N03A001A0
Supply voltage
230V 50Hz
Maximum operating temperature
130°C
Relays (x2)
OMRON G5NB-1A, coil 10VDC, contacts 3A 250VAC, manufactured in Indonesia, batch 02Y7H2
EMI line filter
SCHAFFNER RN112.4J/02, 0.4A/250V, 2x18mH, batch T0722R
UL Certification
WK2 94V-0 0043
Marked
PbF (lead-free)
Frequently Asked Questions

Frequently asked questions about the PCB AS0007548

What code is printed on this PCB of the Fagor FEB24ED3?
N03A001A0, readable on the circuit itself.
Is this PCB Ref. N03A001A0 suitable for a Fagor FEB24AR1B?
Yes, FEB24AR1B is on the list of compatible boilers.
What relays does the PCB of the Fagor FE26TC1N have?
Two OMRON G5NB-1A relays and an EMI filter SCHAFFNER RN112.4J/02.
What voltage and maximum temperature does the PCB of the Fagor FEB24ED3 operate at?
230V 50Hz, with a maximum operating temperature of 130°C.

Spare parts related to Fagor FE 24 NOX

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
PCB Boiler Fagor FEB24ED3 Ref. N03A001A0