PCB Vaillant Turbotec Plus VMW ES 282 5 5 R2 Ref. 0020092372

PCB Vaillant Turbotec Plus VMW ES 282 5 5 R2 Ref. 0020092372

100 €VAT includedIn stock · 2 units

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks out, or the display is unresponsive. Compatible with VMW 24/282/4-5 RV (ref. 0020092372). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
0020092372
Brand
Vaillant
Type of part
PCBs (control boards)
Available units
2 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 0020092372) equips these models. Verified compatibility; check the reference before purchasing.

Turbotec Plus VMW (ES/RV)

  • VMW 24/282/4-5 RV

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.61Fuel valve control faultThe PCB does not correctly control the gas valve (power/output stage or faulty return reading). Check voltage and continuity between the PCB and the valve during demand; if wiring/valve are OK, the cause is the PCB.
F.62Fuel valve disconnection delay faultThe control circuit of the PCB does not cut the power supply to the gas valve within the expected time or interprets the flame extinction late. Check if there is voltage remaining at the valve connector after shutdown and rule out a valve leak/fault; if it persists, the PCB is defective.
F.63EEPROM faultMemory/parameterization error in the boiler's electronics (PCB). If the fault persists after a reset and the power supply is stable, the documented action is to replace the board.
F.64Electronic fault / NTCThe PCB (ADC/analog input) delivers implausible readings from sensors even though the NTC and wiring are fine. Verify sensors and continuity; if the readings are correct but the fault persists, the cause is the PCB.
F.65Fault: PCB temperatureOverheating of the electronics: the internal sensor of the PCB detects temperature out of range or the board overheats. Check for external causes (ventilation/heat sources) and, if it reappears without an external cause, replace the PCB.
F.70Invalid appliance code (DSN)Unconfigured or misaligned PCB with the display after replacement (incorrect/absent DSN). Verify/adjust the DSN in the service menu (e.g., D93) according to the model; if it does not allow parameterization, reprogram or replace the PCB/display according to the manual.
How do I know if this PCB is for my boiler?
Check the reference 0020092372 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.