Main PCB Chaffoteaux Siam 23 CF (TTL 200 I) Ref. 61002711
Main PCB for Chaffoteaux Siam 23 CF, ref. 61002711 (screen-printed PCB 1 002 711, model TTL 200 I). It controls ignition, ionization, pump, and safety features (overtemperature, flue, minimum pressure). Valid for CF versions 220421/220431. Refurbished: always confirm by reading the board and parts list before replacement.
VAT included
Consult via WhatsAppChaffoteaux boilers compatible with reference 61002711
PCB with reference 61002711. Two confirmed compatibilities from two independent sources: SIAM CF P FR (220421) and SIAM CF N FR (220431).
Compatibility confirmed
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux (Chaffoteaux & Maury) SIAM CF P FR (220421) | Siam | Confirmed · 2 sources |
| Chaffoteaux (Chaffoteaux & Maury) SIAM CF N FR (220431) | Siam | Confirmed · 2 sources |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 61002711 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Array
- Array
- Array
- Array
- Array
Symptoms and faults that the PCB 61002711 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
There is no spark or attempt to ignite; lock LED is on.
Cause: Fault in the PCB or lack of power/blown fuse.
Check the 230 V input, 2 A/250 V fuse, and ensure that the ignition module receives a signal from the PCB.
- 02
Spark is present but the gas valve does not open; there is no flame.
Cause: Faulty gas relay/control on PCB or safety in open series.
Check the continuity of the thermostat at 105 °C, smoke sensor at 80 °C, and minimum pressure switch; if they are OK and there is no control voltage, suspect the PCB.
- 03
Intermittent lockouts with a red LED and the need for a reset.
Cause: Control fault on PCB or actual safety trip.
Check probable causes (overheating/ventilation) and rule out hydraulic causes; if it persists without an external cause, PCB.
- 04
The pump works, but there is no ignition sequence.
Cause: Logical fault of the PCB (TTL 200 I) or incoherent signal input.
Check sensors, flow and pressure switch; if inputs are correct and it does not start the sequence, the PCB is faulty.
- 05
A 2 A fuse keeps blowing repeatedly.
Cause: Short circuit on the PCB or on peripherals powered by it.
Isolate loads (igniter, gas valve, pump) and measure consumption; if it continues to blow fuses with loads disconnected, PCB.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the PCB (control board) Chaffoteaux (Chaffoteaux & Maury) 61002711
- OEM reference
- 61002711
- Brand
- Chaffoteaux (Chaffoteaux & Maury)
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Commercial reference
- 61002711
- Silkscreen code on PCB
- 1 002 711 (1002711)
- Logical model on PCB
- TTL 200 I
- Verified compatibility
- Siam CF P FR (220421) and Siam CF N FR (220431)
- Managed safety systems
- Thermostat 105 °C (61002697), flue safety 80 °C (Spott), minimum pressure switch ~0.8 bar (995903)
- Protection fuse
- 2 A, 250 V (60054442)
- Work on the boiler without power and turn off the gas before intervening.
- Download static electricity and avoid short circuits when handling the PCB.
- The flue circuit and the safety thermostats are not bridged; their continuity is only checked.
- Replace gaskets and single-use components after disassembly.
- Check the tightness and evacuation of combustion products at the end.
- Do not replace with 61002907 (model FF); it is not compatible with CF.
- After the change, check the settings and the correct operation of ignition/ionization.