
Saunier Duval Thematek F24 EBT PCB S1047000 Ref. 1008200
If your boiler does not start, locks out, or exhibits erratic behavior, a technical diagnosis must confirm if you need the Saunier Duval Thematek F24 EBT S1047000 PCB. This control board is responsible for managing the ignition, burner modulation, pump, and safety features in the boiler. When it fails, you may see fault codes such as F13, F11, F12, or F18. It is compatible with several models, including F 24 E, F 25 E, and C 24 E, from the ThemaClassic, Themafast, and Thematek ranges, among others. A technician must confirm through diagnosis whether replacement is necessary when these symptoms or faults occur.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- Catalogue reference
- 1008200
- Warranty
- 1 year
Saunier Duval boilers compatible with reference 1008200
PCB with reference 1008200. 33 verified compatibilities: F 25 E and F 24 E.
Verified compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 25 E | ThemaClassic | Verified |
| Saunier Duval F 24 E | ThemaClassic | Verified |
| Saunier Duval C 24 E | ThemaClassic | Verified |
| Saunier Duval C 25 E | ThemaClassic | Verified |
| Saunier Duval C AS 24 E | ThemaClassic | Verified |
| Saunier Duval C AS 25 E | ThemaClassic | Verified |
| Saunier Duval F AS 24 E | ThemaClassic | Verified |
| Saunier Duval F AS 25 E | ThemaClassic | Verified |
| Saunier Duval F AS 30 E | ThemaClassic | Verified |
| Saunier Duval C 24 E | Themafast | Verified |
| Saunier Duval C 25 E | Themafast | Verified |
| Saunier Duval C 28 E | Themafast | Verified |
| Saunier Duval C 30 E | Themafast | Verified |
| Saunier Duval F 24 E | Themafast | Verified |
| Saunier Duval F 25 E | Themafast | Verified |
| Saunier Duval F 25 E H-MOD | Themafast | Verified |
| Saunier Duval F 30 E | Themafast | Verified |
| Saunier Duval F 30 E H-MOD | Themafast | Verified |
| Saunier Duval C 24 E | Thematek | Verified |
| Saunier Duval C 24 EO BT | Thematek | Verified |
| Saunier Duval F 24 E | Thematek | Verified |
| Saunier Duval S C 24 E | Thematek | Verified |
| Saunier Duval S F 24 E | Thematek | Verified |
| Saunier Duval C 24 EA | Isotwin | Verified |
| Saunier Duval C 28 EA | Isotwin | Verified |
| Saunier Duval C 24 E ad04 | Isotwin | Verified |
| Saunier Duval C 24 E de04 | Isotwin | Verified |
| Saunier Duval F 24 E | Isotwin | Verified |
| Saunier Duval F 24 EA | Isotwin | Verified |
| Saunier Duval F 28 EA | Isotwin | Verified |
| Saunier Duval F 30 E H-MOD | Isofast | Verified |
| Saunier Duval F 35 E H-MOD | Isofast | Verified |
| Saunier Duval F 25 E STL | Thema | Verified |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 1008200 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 1008200. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the PCB 1008200
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite, there are no lights on the panel.
Cause: The PCB controls the power supply and operation of the boiler; if it fails, there is no response from the unit.
Check the fuse on the PCB and the main switch before considering that the part is broken.
- 02
There is no hot water or heating, although there is gas and water.
Cause: The PCB commands to open the gas valve and activates the pump; if the control circuit fails, nothing starts.
Check that the connectors to the gas valve and the pump are properly connected and free of rust before replacing the PCB.
- 03
The programmer or thermostat cannot change the state of the boiler.
Cause: The PCB receives and processes the commands; if it fails, it ignores the signals even if they arrive correctly.
Do not bridge contacts or power components directly to test them. Request a technician to check the cause according to the model manual and its revision, without bypassing the protections. The symptom or fault code does not confirm on its own that this part is faulty.
- 04
A relay click is heard in the boiler, but it does not ignite.
Cause: A relay on the PCB that does not close properly causes failed start attempts.
Check if the click coincides with the gas valve ignition attempt before replacing the PCB.
Fault codes Saunier Duval that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| F13 | Main PCB fault | Yes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB. |
| F11 | No signal is reaching the main circuit | Possible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB. |
| F12 | No signal from the user interface | Normally not — it's usually the display or its cable, not this main PCB. |
| F18 | User interface fault | Normally not — it corresponds to the panel/display, not to this PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval 1008200 PCB.
- Catalogue reference
- 1008200
- Uniclima internal SKU
- CECTF24EBT
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 0 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Silkscreen marking in the photograph
- SYMSI7.0
- The title used today by the store combines the references S1047000 and 1008200; there is only one source that supports that substitution relationship, not two independent ones, so it is not considered confirmed.













