Saunier Duval Thematek F24 EBT PCB S1047000 Ref. 1008200

Saunier Duval Thematek F24 EBT PCB S1047000 Ref. 1008200

If your boiler does not start, locks out, or exhibits erratic behavior, a technical diagnosis must confirm if you need the Saunier Duval Thematek F24 EBT S1047000 PCB. This control board is responsible for managing the ignition, burner modulation, pump, and safety features in the boiler. When it fails, you may see fault codes such as F13, F11, F12, or F18. It is compatible with several models, including F 24 E, F 25 E, and C 24 E, from the ThemaClassic, Themafast, and Thematek ranges, among others. A technician must confirm through diagnosis whether replacement is necessary when these symptoms or faults occur.

Catalogue reference
1008200
Warranty
1 year
VAT included OUT OF STOCK
Compatibility

Saunier Duval boilers compatible with reference 1008200

PCB with reference 1008200. 33 verified compatibilities: F 25 E and F 24 E.

Verified compatibility

Boiler modelFamilyVerification
Saunier Duval F 25 EThemaClassicVerified
Saunier Duval F 24 EThemaClassicVerified
Saunier Duval C 24 EThemaClassicVerified
Saunier Duval C 25 EThemaClassicVerified
Saunier Duval C AS 24 EThemaClassicVerified
Saunier Duval C AS 25 EThemaClassicVerified
Saunier Duval F AS 24 EThemaClassicVerified
Saunier Duval F AS 25 EThemaClassicVerified
Saunier Duval F AS 30 EThemaClassicVerified
Saunier Duval C 24 EThemafastVerified
Saunier Duval C 25 EThemafastVerified
Saunier Duval C 28 EThemafastVerified
Saunier Duval C 30 EThemafastVerified
Saunier Duval F 24 EThemafastVerified
Saunier Duval F 25 EThemafastVerified
Saunier Duval F 25 E H-MODThemafastVerified
Saunier Duval F 30 EThemafastVerified
Saunier Duval F 30 E H-MODThemafastVerified
Saunier Duval C 24 EThematekVerified
Saunier Duval C 24 EO BTThematekVerified
Saunier Duval F 24 EThematekVerified
Saunier Duval S C 24 EThematekVerified
Saunier Duval S F 24 EThematekVerified
Saunier Duval C 24 EAIsotwinVerified
Saunier Duval C 28 EAIsotwinVerified
Saunier Duval C 24 E ad04IsotwinVerified
Saunier Duval C 24 E de04IsotwinVerified
Saunier Duval F 24 EIsotwinVerified
Saunier Duval F 24 EAIsotwinVerified
Saunier Duval F 28 EAIsotwinVerified
Saunier Duval F 30 E H-MODIsofastVerified
Saunier Duval F 35 E H-MODIsofastVerified
Saunier Duval F 25 E STLThemaVerified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 1008200 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 1008200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 1008200

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite, there are no lights on the panel.

    Cause: The PCB controls the power supply and operation of the boiler; if it fails, there is no response from the unit.

    Check the fuse on the PCB and the main switch before considering that the part is broken.

  • 02

    There is no hot water or heating, although there is gas and water.

    Cause: The PCB commands to open the gas valve and activates the pump; if the control circuit fails, nothing starts.

    Check that the connectors to the gas valve and the pump are properly connected and free of rust before replacing the PCB.

  • 03

    The programmer or thermostat cannot change the state of the boiler.

    Cause: The PCB receives and processes the commands; if it fails, it ignores the signals even if they arrive correctly.

    Do not bridge contacts or power components directly to test them. Request a technician to check the cause according to the model manual and its revision, without bypassing the protections. The symptom or fault code does not confirm on its own that this part is faulty.

  • 04

    A relay click is heard in the boiler, but it does not ignite.

    Cause: A relay on the PCB that does not close properly causes failed start attempts.

    Check if the click coincides with the gas valve ignition attempt before replacing the PCB.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
F13Main PCB faultYes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB.
F11No signal is reaching the main circuitPossible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB.
F12No signal from the user interfaceNormally not — it's usually the display or its cable, not this main PCB.
F18User interface faultNormally not — it corresponds to the panel/display, not to this PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval 1008200 PCB.

Catalogue reference
1008200
Uniclima internal SKU
CECTF24EBT
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Silkscreen marking in the photograph
SYMSI7.0
Before purchasing
  • The title used today by the store combines the references S1047000 and 1008200; there is only one source that supports that substitution relationship, not two independent ones, so it is not considered confirmed.
Frequently asked questions

Frequently asked questions about the PCB 1008200

Is this PCB compatible with a Saunier Duval Themaclassic F30E Plus?
It is compatible with the Themaclassic range F24E, F24E Plus, F30E, F30E Plus, F30E SB, F35E, and F8E SB; check the exact model of your boiler.

Spare parts related to Saunier Duval ThemaClassic

Delivery calculated by destination Delivery time shown at checkout
1-year warranty inspected and tested
14-day return uninstalled parts
Technical support we verify your model
Saunier Duval Thematek F24 EBT PCB S1047000 Ref. 1008200