Saunier Duval Thematek F 24 E BT PCB Ref. 120404/9
The Saunier Duval Thematek F 24 E BT PCB (control board) Ref. 120404/9 controls the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler does not start, locks out, or exhibits erratic behavior, potentially displaying fault codes 11 or 13. This part is compatible with several models, including Thematek F 24 E, Thematek F 24 E BT, and Themaclassic C 24 E, among others. A technician must confirm through diagnosis whether it needs to be replaced if you experience issues with your boiler's operation.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- Catalogue reference
- 120401
- Warranty
- 1 year
Saunier Duval boilers compatible with reference 120401
PCB with reference 120401. Six confirmed compatibilities: Thematek F 24 E and Thematek F 24 E BT.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Thematek F 24 E | Thematek | Contrasted |
| Saunier Duval Thematek F 24 E BT | Thematek | Contrasted |
| Saunier Duval Thematek C 24 E | Thematek | Contrasted |
| Saunier Duval Themaclassic C 24 E | Themaclassic | Contrasted |
| Saunier Duval Themaclassic F 24 E | Themaclassic | Contrasted |
| Saunier Duval Themafast F 30 E | Themafast | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number 120401 is the one for your boiler.
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 120401. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the PCB 120401
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler restarts by itself and works for a while, but then it fails again.
Cause: Intermittent issues on the PCB manifest as follows: the system recovers on its own, but the problem persists.
Note how many days pass between each reset; if the interval decreases, the PCB is deteriorating and the technical diagnosis must confirm whether it is necessary to replace it before it fails completely.
- 02
There is no response when turning on the boiler: no display or lights.
Cause: A fault in the power supply to the PCB prevents the entire system from receiving electricity, even though the power in the house is fine.
Make sure that the power outlet works with another device and that the main switch is on before considering the PCB as faulty.
- 03
The boiler beeps or shows an error when starting, always with a different fault code.
Cause: Faults on the PCB that affect the microprocessor produce erratic readings that do not always reflect the real cause of the fault code.
Compare the code that appears with the boiler manual and first check the component it indicates (sensor, pressure switch); if that component is fine, the PCB could be the cause of the problem.
- 04
The burner or the pump do not receive the command to operate even though the boiler requests it.
Cause: This PCB controls the outputs to those components; if the relay or the output stage fails, the command is not sent.
Check if the component is receiving power at the moment it should be activated; if it is not receiving power, the lack of command comes from the PCB.
Fault codes Saunier Duval that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| 11 | No signal is reaching the main circuit | Main control board (PCB) fault in bus/MMI input management: the interface sends but the PCB does not receive. First, check the MMI cable/connector and 5 V on the interface; if there is continuity/voltage and the UI responds, the cause is the PCB (measure data signal on the board and, if there is no communication, replace it). |
| 13 | Main PCB fault | This symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval 120401 PCB.
- Catalogue reference
- 120401
- Uniclima internal SKU
- PLCTMK24
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 2 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- PCB code (silkscreen)
- 735004 V087_C
- Production code (label)
- 4000 120404/9 (barcode 0400712104008084351)
- Fuse
- 125mAT / USE 250V
- Correct reference
- 120404/9 — catalog published 120401 ()
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Thematek C 24 E Manual (PDF) Document © Saunier Duval, provided as a technical reference.