Wilo HB15/6-2 Circulating Pump Saunier Duval Thema Condens F24 Ref. 0020016475

Wilo HB15/6-2 Circulating Pump Saunier Duval Thema Condens F24 Ref. 0020016475

Wilo circulator pump, model HB15/6-2, installed in Saunier Duval Thema Condens F18/F24/F30E and Themafast/Themaplus Condens boilers. It circulates the water of the heating circuit between the boiler and the radiators. According to the label, it operates at 230V, has two speeds (62W and 83W), and can handle up to TF95. Replacement requires first confirming the fault of the part through technical diagnosis, even when circulation fails or it leaks.

Type of part
Pumps
Catalogue reference
0020087276
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Saunier Duval boilers compatible with reference 0020087276

Circulating pump with reference 0020087276. Eight confirmed compatibilities: CONDENS F AS 24 E and CONDENS F18.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval CONDENS F AS 24 ETHEMAContrasted
Saunier Duval CONDENS F18THEMAContrasted
Saunier Duval CONDENS F24THEMAContrasted
Saunier Duval CONDENS F30ETHEMAContrasted
Saunier Duval CONDENS F24ETHEMAFASTContrasted
Saunier Duval CONDENS F30ETHEMAFASTContrasted
Saunier Duval NOx F30THEMAFASTContrasted
Saunier Duval CONDENS F30ETHEMAPLUSContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020087276 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020087276. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the circulation pump 0020087276

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The heating takes a long time to warm up or does not heat at all, even though the boiler ignites.

    Cause: The hot water is not circulating properly, which causes the more distant radiators not to heat up.

    Adjust the pump to the highest speed before replacing it, in case the issue is just with the flow rate.

  • 02

    A thump or strange noise is heard when the pump changes speed.

    Cause: The change in speed may indicate that the bearing is worn out.

    Observe whether the noise occurs only when changing speed or also during continuous operation: this will help you identify if it is an electronic or mechanical problem.

  • 03

    Water is appearing at the base of the boiler, near the pump.

    Cause: The shaft seal wears out over time and may start to leak water.

    Dry the area, turn on the boiler, and locate the source of the dripping before replacing the part.

  • 04

    The pump does not rotate after a period of not using the boiler.

    Cause: The impeller can become blocked by deposits if the water has been stagnant for several weeks.

    Unplug the boiler and try to unlock the shaft manually through the front slot before replacing it.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
33Control cycle: the air pressure switch does not switch.The differential pressure switch for fumes does not close when the fan starts; check with a manometer/ohmmeter the switching of the pressure switch and ensure there are no obstructions/water in the inlets and flue duct.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval circulator pump 0020087276

Catalogue reference
0020087276
Uniclima internal SKU
BCSDTCF24
Brand
Saunier Duval
Type of part
Pumps
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

manufacturer
Wilo
code
0020016475 (WILO Type HB15/6-2, No. 4516718)
voltage
230V
frequency
50Hz
power
62W (speed I) / 83W (speed II)
current
0.27A (speed I) / 0.36A (speed II)
capacitor
2.6uF
Protection rating
IP44
Insulation class
Class F
Nominal pressure
PN3
Max fluid temp
TF95
Frequently Asked Questions

Frequently asked questions about the circulation pump 0020087276

Which reference should I request for the Wilo HB15/6-2 pump of the Saunier Duval Thema Condens F24, the one from the label or the one from the catalog?
The label indicates 0020016475 (Wilo Typ HB15/6-2, No. 4516718); the catalog shows 0020087276. The reference on the label takes precedence.
Does the Wilo HB15/6-2 pump also work for the Saunier Duval Themafast Condens F30E?
Yes, Themafast Condens F30E is on the list of compatible boilers, along with Thema Condens F18/F24/F30E, Thema Condens F AS 24E, Themafast Condens F24E, Themafast Nox F30, and Themaplus Condens F30E.
How many speeds does the Wilo HB15/6-2 pump of the Thema Condens F24 have?
Two speeds, with 62W and 83W according to the label.
What is the maximum operating temperature that the pump of the Thema Condens F24 can handle?
According to the label, it supports up to TF95, with a power supply of 230V.
When should the Wilo HB15/6-2 pump of the Thema Condens F24 be replaced?
The technical diagnosis must confirm that it is necessary to replace it, even when there is a failure in the water circulation of the heating circuit or the pump is leaking.

Spare parts related to Saunier Duval THEMA

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Wilo HB15/6-2 Circulating Pump Saunier Duval Thema Condens F24 Ref. 0020016475