Grundfos Circulating Pump UP 15-60 A0 For Saunier Duval Themafast F24E - Ref. 0020087276
Refurbished Saunier Duval Pumps Grundfos

Grundfos Circulating Pump UP 15-60 A0 For Saunier Duval Themafast F24E - Ref. 0020087276

Circulating pump motor Grundfos, model UP 15-60 A0. It moves water through the circuit of the Saunier Duval Themafast/Thema Condens boiler. Replacement requires first confirming the fault of the part through technical diagnosis, even when it does not start, makes noise, leaks, or the impeller is blocked after a period of inactivity. Actual manufacturer is Grundfos, different from the commercial brand of the boiler.

Type of part
Pumps
Catalogue reference
0020087276
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Saunier Duval boilers compatible with reference 0020087276

Circulating pump with reference 0020087276. Five confirmed compatibilities: Themafast Condens F 24 E and Themafast Condens F 30 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Themafast Condens F 24 EThemafast CondensContrasted
Saunier Duval Themafast Condens F 30 EThemafast CondensContrasted
Saunier Duval Themafast NOx F 30Themafast NOxContrasted
Saunier Duval Isofast 21 CondensIsofast CondensContrasted
Saunier Duval Isofast Condens F 35 AIsofast CondensContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020087276 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020087276. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the circulation pump 0020087276

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler is not heating or is heating poorly.

    Cause: The pump is blocked and is not pushing water to the heating circuit.

    Check if the pump vibrates or hums when the heating is turned on; if it doesn't transmit anything, it may be blocked.

  • 02

    Noise in the pump motor

    Cause: Air in the circuit or low pressure generates that noise in the motor.

    Check the pressure gauge of the boiler and bleed the air from the system before replacing the pump.

  • 03

    Water leak from the pump body

    Cause: The gasket or the internal mechanical seal has lost tightness.

    Dry the area and check if the leak reappears after a cycle of operation, before declaring the pump as lost.

  • 04

    Pump that won't start after a period of inactivity

    Cause: The rotor gets stuck due to prolonged inactivity, which is typical when resuming heating after the summer.

    Try to manually free the shaft through the front slot of the motor before replacing it.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
F.22Safety shutdown: lack of waterIf the pump motor is blocked/faulty or disconnected (wiring/PCB), there is no circulation and the control interprets a lack of water. Check the pump start in test P.0, presence of PWM/230 V voltage, and motor continuity/consumption.
F.23Safety shutdown: excessive temperature variationA pump without flow (blocked or with reduced power) causes an excessive ΔT flow/return. Check the pump's rotation/speed, bleed air, and ΔT in the heat exchanger; verify PWM/230 V control.
F.24Safety shutdown: temperature rise too fastIf the pump is stopped or performing poorly, the flow rises very quickly as the water does not circulate. Check the power supply and rotation of the pump and bleed the system; if it does not respond in P.0, replace the pump.
F.75Pump error, lack of waterUpon start-up, the electronics await a pressure variation when the pump starts; if the motor does not turn or does not generate flow, there is no change and F.75 appears. Check the pump test and pressure change, voltage to the pump, and the condition of the impeller.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval circulator pump 0020087276

Catalogue reference
0020087276
Uniclima internal SKU
MBCCTF24E
Brand
Saunier Duval
Type of part
Pumps
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer
Grundfos
Model
Grundfos Type UP 15-60 A0
Factory code (P/N)
59996114
IWC code
4000120855
Voltage
230V
Frequency
50Hz
Current
0.45 A
Power
105 W
Condenser
2.5 µF
Degree of protection
IP44
Insulation class
Class F
Maximum fluid temperature
TF95
Maximum pressure
3 bar
Before purchasing
  • The actual manufacturer of the pump is Grundfos, not Saunier Duval.
Frequently Asked Questions

Frequently asked questions about the circulation pump 0020087276

Is the Grundfos UP 15-60 A0 circulator pump with reference 0020087276 an original part from Saunier Duval?
No; the actual manufacturer is Grundfos, although Saunier Duval installs it as standard in some models.
What voltage does this circulator pump need?
230V at 50Hz, according to the label on the pump itself.
Is the Grundfos UP 15-60 A0 pump compatible with the Themafast Condens F24E boiler?
Yes, it is listed as compatible along with the Themafast Condens F 30 E, Themafast NOx F 30, Isofast 21 Condens, and Isofast Condens F 35 A.
Is there another code to identify the boiler pump apart from the reference 0020087276?
Yes, the factory P/N is 59996114 and it also carries the code IWC 4000120855.
What are the documented fault codes for this pump?
The fault codes are F.22, F.23, F.24, and F.75.
Why should I change the pump of my boiler?
When it doesn't start, makes noise, leaks, or the impeller gets stuck after a period of being idle.

Spare parts related to Saunier Duval Themafast Condens

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Grundfos Circulating Pump UP 15-60 A0 For Saunier Duval Themafast F24E - Ref. 0020087276