Wilo Circulator Pump HB15/6.7-2 Saunier Duval Themafast F 30 E - Ref. S1061800
Wilo HB15/6.7-2 circulating pump, manufactured by Wilo, installed in Saunier Duval boilers of the Themafast F25/F30 and Themaplus C23/C25/C30 and F25/F30 series. It circulates water through the heating circuit. It is replaced when the boiler does not heat, the radiators remain cold, or the pump makes noise. Its label codes are 4514062 and 4514293; the current catalog reference, S1061800, does not match and appears repeated in another different SKU.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S1061800
Circulating pump with reference S1061800. Four confirmed compatibilities: Themafast F 25 E H-MOD and Themafast F25E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Themafast F 25 E H-MOD | Themafast | Contrasted |
| Saunier Duval Themafast F25E | Themafast | Contrasted |
| Saunier Duval Themafast F 30 E H-MOD | Themafast | Contrasted |
| Saunier Duval Themafast F30E | Themafast | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S1061800 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S1061800. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the circulator pump S1061800 resolves.
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler turns on and seems to work, but the radiators are cold or just lukewarm.
Cause: The pump is not circulating water through the heating circuit, so the heat is not reaching the radiators even though the burner is working.
Check with a screwdriver on the front screw if the shaft turns freely and bleed the air from the circuit before declaring the pump faulty.
- 02
A humming or rubbing noise is heard in the pump when starting up.
Cause: The impeller is rubbing or there is air and scale accumulated in the pump body, which is forcing the motor.
Bleed the air from the circuit and the pump body itself using the bleed screw before replacing it.
- 03
The pump does not start after the summer or a long shutdown.
Cause: The shaft seizes due to sediment or lime buildup during inactivity.
Try to manually unlock the shaft with the front screw before considering the pump as faulty.
- 04
Water or moisture appears at the base of the pump, near the shaft.
Cause: The mechanical seal of the shaft has lost its tightness and is allowing water to pass through.
Dry the area and check if the leak reappears with the boiler running, to rule out that it is moisture from a recent bleed.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F.23 | Safety shutdown due to excessive temperature difference (very reduced circulation). | If the circulating pump (S1061800) is blocked or not rotating, the flow rate drops: the supply heats up quickly and the return remains cold, triggering F.23. Check the voltage to the pump, consumption/start-up, and actual flow rate (bleeding or test program if applicable). |
| F.24 | Safety shutdown due to excessively rapid temperature increase (lack of circulation). | A faulty heating pump or one without flow causes a large rise gradient in the supply and triggers F.24. Check that the pump receives 230 V, starts, and that the system is correctly bled. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S1061800 circulation pump.
- Catalogue reference
- S1061800
- Brand
- Saunier Duval
- Type of part
- Pumps
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Model
- HB15/6.7-2
- Printed codes
- 4514062 / 4514293
- Protection rating
- IP44
- Nominal pressure
- PN3
- Speeds (rpm)
- 2500 / 2180
- Current (A)
- 0,38 / 0,29
- Power (W)
- 85 / 64
- Condenser
- 2.6 µF - 400VDB
- Voltage/frequency
- ~230V - 50Hz
- Insulation class
- F - TF95
- Manufacturing date
- week 07/2005