Saunier Duval Thematek Grundfos Circulating Pump Ref. S1005200
RefurbishedSaunier DuvalPumpsGrundfos

Saunier Duval Thematek Grundfos Circulating Pump Ref. S1005200

Stock · 4 units

Grundfos circulating pump (Type UP 15-50 A0) mounted in Saunier Duval Thematek and Themaclassic boilers. It circulates the water in the heating circuit. It is replaced when the water does not circulate, makes noise, leaks from the seal, or the rotor is blocked. Power supply 230V~ 50Hz, IP44, up to 3 bar, with 85W of power.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S1005200

Circulating pump with reference S1005200. Five confirmed compatibilities: C 24 E and C AS 24 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval C 24 EThemaClassicContrasted
Saunier Duval C AS 24 EThemaClassicContrasted
Saunier Duval F 24 EThemaClassicContrasted
Saunier Duval F 25 EThemaClassicContrasted
Saunier Duval C 24 EThemafastContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1005200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1005200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the circulator pump S1005200 resolves.

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler ignites and operates, but the radiators do not heat or heat very little.

    Cause: The pump does not move the necessary flow of water through the heating circuit, even though the burner operates normally.

    Check that the pump is spinning and is not blocked by touching its casing: if it vibrates but does not move water, bleed the circuit before replacing it.

  • 02

    There is a buzzing or strange noise in the pump area.

    Cause: Air in the rotor, cavitation due to low pressure, or a worn bearing generate that characteristic noise.

    Check the circuit pressure on the manometer and bleed the air from the system before declaring the pump faulty.

  • 03

    Water or moisture is dripping right under the pump.

    Cause: The mechanical seal of the shaft has worn out and no longer seals the passage of water.

    Locate whether the leak is coming from the pump body itself and not from a nearby joint or fitting before replacing it.

  • 04

    The pump makes a buzzing sound but the shaft does not rotate, or it does not start at all.

    Cause: The rotor has seized up, something typical after being idle for months in summer, due to deposits or accumulated scale.

    With the boiler turned off, try to free the shaft by turning the front screw with a flat screwdriver before assuming that it needs to be replaced.

  • 05

    The radiators are cold even though the boiler indicates that it is operating normally.

    Cause: Without water circulation, the heat generated does not reach the heating circuit even though the burner ignites properly.

    Check that the radiator and circuit shut-off valves are open before considering the pump.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F5Overheating of the primary circuit.If the S1005200 circulating pump is blocked or not rotating, there is no flow in the primary circuit and the temperature rises very quickly, triggering the safety limiter/thermostat. Check by measuring 230 V at the pump terminals during demand, checking consumption/rotation and bleeding to rule out air or obstructions.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S1005200 circulation pump.

Catalogue reference
S1005200
Brand
Saunier Duval
Type of part
Pumps
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

manufacturer
Grundfos
type
UP 15-50 A0
PN code
59994584
Production code PC
0505HHD
IWC code
4000120626
voltage
230V~
frequency
50Hz
Power p1
85W
Current im
0.38A
capacitor
2µF
Thermal protection
TF95
IP rating
IP44
Insulation class
Class F
Maximum pressure
3 bar
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the S1005200 circulation pump.

Does this Grundfos S1005200 pump work for a Saunier Duval Thematek C 24 E?
Yes, the Thematek C 24 E is on the list of boilers compatible with the reference S1005200.
Who manufactures the pump for the ThemaClassic F 24 E range?
The Grundfos factory; the part's label has its logo and the text Grundfos, model Type UP 15-50 A0.
What fault indicates that this pump needs to be replaced in a Saunier Duval Thematek?
It is replaced when the water in the heating circuit does not circulate, the pump makes noise, it leaks at the seal, or the rotor gets stuck.
What pressure and power does the Grundfos S1005200 pump support?
Up to 3 bar and 85W of power, with a supply of 230V~ 50Hz and IP44.
Is the pump the same for the ThemaClassic C 24 E range and the Themafast C 24 E range?
Yes, both boilers are on the list of models compatible with this Grundfos S1005200 pump, reference BCTSF24E.

Spare parts related to Saunier Duval ThemaClassic

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Thematek Grundfos Circulating Pump Ref. S1005200