Ignition Transformer Saunier Duval Thema / Combitek / Themaplus 23E (ref. 05111000)

Ignition Transformer Saunier Duval Thema / Combitek / Themaplus 23E (ref. 05111000)

25 €VAT includedIn stock · 5 units

Ignition transformer for Saunier Duval boilers Combitek, Thelia, Thema, and ThemaPlus F/C 23E. Article code Art.Nr. 07000068, model code ZAG 2 XV 01, power supply 220-240V 50-60Hz, 2.5VA, up to +85°C. It is replaced when the boiler does not ignite due to a lack of spark at the ignition electrode.

Spare parts related to Saunier Duval Thema

Compatibility

Saunier Duval boilers compatible with reference 05111000

Ignition transformer with reference 05111000. Ten confirmed compatibilities with two independent sources: Thema C 23 E and Thema F 23 E. Verify the printed reference on your part before purchasing.

Compatibility confirmed

Boiler modelFamilyVerification
Saunier Duval Thema C 23 EThemaConfirmed · 2 sources
Saunier Duval Thema F 23 EThemaConfirmed · 2 sources
Saunier Duval Thema C 23 AS EThemaConfirmed · 2 sources
Saunier Duval Thema F 23 AS EThemaConfirmed · 2 sources
Saunier Duval Themaplus F 23 EThemaplusConfirmed · 2 sources
Saunier Duval Themaplus C 23 EThemaplusConfirmed · 2 sources
Saunier Duval Combitek F 23 ECombitekConfirmed · 2 sources
Saunier Duval Isofast C 28 E NOxIsofastConfirmed · 2 sources
Saunier Duval Thelia 23 ETheliaConfirmed · 2 sources
Saunier Duval Themis 23 EThemisConfirmed · 2 sources

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 05111000 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Locate the reference printed on the body of the ignition transformer you have installed: it should indicate 05111000.
  2. Check your boiler model on the nameplate and look for it in the list of compatible models on this page.
  3. Compare the connections and the body with the original part before installing.
  4. If you have any doubts, send us a photo of the screen printing via WhatsApp and we'll confirm it for you before you purchase.
Diagnosis

Symptoms and faults resolved by ignition transformer 05111000

The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:

The boiler does not ignite and there is no noticeable spark clicking sound.

Cause: No output voltage from the transformer, the electrode does not generate an arc, and the gas never ignites.

Listen to the start-up with the cover on; the ticking of the spark should be clearly audible even if it's low.

The burner tries to ignite and turns off immediately.

Cause: A weak spark may ignite the gas for an instant but not sustain the flame long enough for the control unit to confirm it.

Check the gas pressure and ensure that the gas valve opens properly before assuming that the fault is solely with the transformer.

The boiler locks out due to ignition failure after two or three attempts.

Cause: If the electrode does not receive sufficient voltage from the transformer, the control unit does not detect a flame and shuts off for safety.

Check that the ignition electrode is not broken, sooty, or improperly positioned before replacing the transformer.

The ignition fault repeats the same way, start after start.

Cause: Unlike a gas fault, which is usually more erratic, a damaged transformer tends to fail consistently and repeatedly.

Note if the behavior is always identical; if so, it is an indication in favor of the transformer over other more variable causes.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Saunier Duval Ignition Transformer Datasheet 05111000

OEM reference
05111000
Brand
Saunier Duval
Type of part
Transformers
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

item code (Art.Nr.)
07000068
label
model code
ZAG 2 XV 01
label
variant
10 Hz
label
voltage
220-240 V
label
network frequency
50-60 Hz
label
power
2.5 VA
label
maximum temperature
+85 °C
label
CE code
CE-0085AU0189
label
connector marking
ANSTOSS
label
Before purchasing
  • The actual manufacturer of this part is not listed; it is identified by its article code (Art.Nr. 07000068) and by the boiler reference.
  • The item code engraved on the piece (07000068) is different from the catalog reference (05111000): they are numbering systems from different systems, it's normal.
  • No data could be cross-verified with external sources (0 sources).
Frequently Asked Questions

Frequently Asked Questions about Ignition Transformer 05111000

Which manufacturer has the ignition transformer for the Saunier Duval Combitek F 23 E?
It is not marked on the piece. It is identified by the article code Art.Nr. 07000068.
What code is engraved on the ignition transformer of the Thelia 23 E?
Art.Nr. 07000068 and model code ZAG 2 XV 01.
What mains voltage does the ignition transformer F 23 E require?
220-240V, 50-60Hz according to the label.
Is reference 05111000 the one engraved on the transformer part of the Thema F 23 E?
No. That is the Saunier Duval catalog code; the part is marked with Art.Nr. 07000068.
Is this ignition transformer suitable for my ThemaPlus F 23 E?
Yes, the ThemaPlus F 23 E is on the list of compatible boilers.
When should the ignition transformer of the Combitek F 23 E be replaced?
When the boiler does not ignite due to a lack of spark at the ignition electrode.
Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model