Saunier Duval Isofast Condens MA 36-CF/1-CfI boiler (n-int)
The IsoFast H-Condens MA 36-CF/1-CfI (N-INT) offers 3.0-25.0 kW of heating at 80/60 °C, 20.9 l/min of domestic hot water in the ΔT25 test with an inlet of 10 °C and 3 liters of micro-accumulation. The technical sheet identifies this unit with MiSet Radio and MiGo Link as standard. Equipment without installation; please confirm the accessories for this configuration. VAT and mainland shipping included.
- Heating power G20 (80/60 °C)
- 3.0-25.0 kW
- Domestic hot water flow rate (ΔT 25 °C, inlet 10 °C)
- 20.9 l/min
- Micro-accumulation DHW
- 3 liters
The model, at a glance
Wall-mounted boiler IsoFast H-Condens MA 36-CF/1-CfI (N-INT), with 3 liters of micro-accumulation, MiSet Radio and MiGo Link as standard.
- Heating power G20 (80/60 °C)
- 3.0-25.0 kW
- Domestic hot water flow rate (ΔT 25 °C, inlet 10 °C)
- 20.9 l/min
- Micro-accumulation DHW
- 3 liters
Read the full description and what it includes.
The Saunier Duval IsoFast MiConnect H-Condens MA 36-CF/1-CfI (N-INT) is a wall-mounted condensing boiler for natural gas. Its professional sheet states a useful heating power of 3.0 to 25.0 kW at 80/60 °C and 3.2 to 26.5 kW at 50/30 °C; the domestic hot water power is listed separately, with a range of 3.1 to 36.4 kW.
For domestic hot water, it incorporates 3 liters of MicroFast 3.0 micro-accumulation. The published flow rate is 20.9 l/min at ΔT 25 °C with an inlet water temperature of 10 °C: this is a test condition, not a promise of continuous flow or simultaneity. The actual demand depends on temperature, pressure, fixtures, and consumption of the household.
The CfI column (N-INT) is identified with MiSet Radio and MiGo Link as standard. It features FlameFit combustion technology, a modulation of 1:12, an ErP seasonal efficiency of 94%, and an A/XL rating for domestic hot water. The technical sheet indicates natural gas and that the conversion to propane is not available for this variant.
The device measures 470 x 893 x 392 mm and weighs 48 kg. The dimensions refer to the equipment, not the final opening: the installation must check connections, flue, support, and service access. The technical sheet provides indicative flue routes and refers to the specific flue instructions; they do not become a universal installation.
What is included in the purchase?
Equipo sin instalación. Confirma los accesorios de esta configuración.
Price including VAT and shipping to mainland Spain. Installation, adaptations, and commissioning are valued separately.
What to check before installing this boiler
The choice of equipment does not replace the inspection of the installation by a qualified professional.
- Confirm the model and commercial reference, the type of gas, and the supply configuration in the manufacturer's documentation.
- Ask a qualified installer to assess the heating and domestic hot water demand; compare measured flow rates at the same temperature difference.
- Check dimensions, connections, flue gas evacuation, condensate drainage, and controls compatible with the existing installation.
- Confirm the included accessories and the delivery time before scheduling the installation. The online purchase of the equipment does not include installation or commissioning.
Datos técnicos de Caldera Saunier Duval Isofast Condens MA 36-CF/1-CfI (n-int)
- Brand
- Saunier Duval
- Model
- Saunier Duval Isofast Condens MA 36-CF/1-CfI boiler (n-int)
- Status
- New
- Supply scope
- Equipment without installation; please confirm the accessories for this configuration.
- Shipping
- Included in mainland Spain. Please confirm the deadline.
Specifications and dimensions of the model
Compare each magnitude under its testing conditions: heating, domestic hot water, efficiency, and dimensions.
- Useful heating output (80/60 °C, G20)
- 3.0-25.0 kW
Heating - Useful heating output (50/30 °C, G20)
- 3.2-26.5 kW
Heating - PCI efficiency (50/30 °C)
- 104 %
Heating - PCI efficiency (80/60 °C)
- 98 %
Heating - Supply temperature range
- 30-80 °C
Heating - Nominal heating flow rate (ΔT 20 K)
- 1.077 l/h
Heating - Heating expansion vessel
- 12 l
Heating - Maximum working pressure for heating
- 3 bar
Heating - Domestic hot water power
- 3.1-36.4 kW
Hot water - Domestic hot water flow rate (ΔT 25 °C, inlet 10 °C)
- 20.9 l/min
Hot water - Domestic hot water temperature range
- 35-60 °C
Hot water - Maximum allowable pressure for domestic hot water
- 10 bar
Hot water - ACS volume, MicroFast 3.0 micro-accumulation
- 3 l
Hot water - Seasonal ErP efficiency
- 94 %
Efficiency and control - Declared sound level
- 50 dB(A)
Efficiency and control - Heating efficiency with MiSet
- A
Efficiency and control - Efficiency of domestic hot water / demand profile
- A / XL
Efficiency and control - Combustion technology
- FlameFit
Efficiency and control - Modulation
- 1:12
Efficiency and control - Primary heat exchanger
- Stainless steel
Construction and gas - Supply gas
- Natural gas
Construction and gas - Propane conversion
- Not available
Construction and gas - Maximum electrical consumption
- 97 W
Electricity - Standby power consumption
- < 2 W
Electricity - Electrical protection
- IPX5D
Electricity - Dimensions (width x height x depth)
- 470 x 893 x 392 mm
Dimensions and installation - Weight
- 48 kg
Dimensions and installation - 60/100 horizontal
- 10 m + 1 elbow 87°; indicative data, consult evacuation instructions 0020294231
Flue gas evacuation - 60/100 vertical
- 9 m; indicative data, consult evacuation instructions 0020294231
Flue gas evacuation - 80/125
- 25 m + 3 elbows 87°; indicative data, consult evacuation instructions 0020294231
Flue gas evacuation - 80/80 evacuation
- 33 m + 3 elbows 87°; maximum 30 m vertically; indicative data, consult evacuation instructions 0020294231
Flue gas evacuation - 80/80 air intake
- 8 m + 1 elbow 87°; only if the intake and discharge are on opposite facades or slopes (note 2); indicative data, consult evacuation instructions 0020294231
Flue gas evacuation - Approved types
- C13, C33, C43, C53, C83, C93, B23P, B33
Flue gas evacuation - CE Certificate
- 0063DL3987
Flue gas evacuation
PDF and documentation of the model
Original documents, unmodified. Refer to the installation plan and the conditions of each data point before selecting the equipment.
- IsoFast MiConnect H-Condens MA 36-CF/1-CfI (N-INT)PDF · 2 páginas · Saunier DuvalView original on the manufacturer's website ↗
The gallery sheets are summaries of Uniclima based on these documents. The external volume diagram does not represent connections, accessories, or service distances.