Saunier Duval Thelia Condens 25-A boiler
Condensing boiler · New equipmentSaunier Duval Thelia Condens 25-A

Saunier Duval Thelia Condens 25-A boiler

VAT includedIn stock

The Thelia Condens 25-A offers 5.0-18.1 kW of heating at 80/60 °C and up to 25.2 kW of domestic hot water with natural gas. It combines Warm Start with a specific flow rate D30 of 12.1 l/min and a limiter of 8 l/min. The reference 12016089 is without control; its body is 300 mm deep and weighs 31.6 kg net. H-ES variant without control. Installation not included. VAT and mainland shipping included.

Heating power (80/60 °C, G20)
5.0-18.1 kW
Specific flow rate for domestic hot water (ΔT 30 K)
12.1 l/min
Dimensions (height x width x depth)
740 x 418 x 300 mm
Condensing boiler

The model, at a glance

Saunier Duval Thelia Condens 25-A: 5.0-18.1 kW in heating, domestic hot water D30 of 12.1 l/min, Warm Start and 300 mm depth. Natural gas, without control.

Heating power (80/60 °C, G20)
5.0-18.1 kW
Specific flow rate for domestic hot water (ΔT 30 K)
12.1 l/min
Dimensions (height x width x depth)
740 x 418 x 300 mm
Read the full description and what it includes.

The Saunier Duval Thelia Condens 25-A offers heating from 5.0 to 18.1 kW at 80/60 °C and domestic hot water from 5.0 to 25.2 kW with natural gas. At 50/30 °C, it delivers 5.3-19.1 kW of useful output. It is an option to consider when the calculated load does not require the maximum of a Semia 30, paying attention to the minimum of 5 kW in low demand areas. The maximum factory setting for heating is configured at 15 kW and should be checked by the installer.

The Warm Start feature reduces the wait time when requesting hot water. The specific flow rate of 12.1 l/min at ΔT 30 K should not be replaced by the 14.6 l/min measured at ΔT 25 K; at ΔT 35 K, the value is 10.4 l/min. The sanitary limiter of 8 l/min is another condition that matters in actual use. This data allows for evaluating a shower and other consumption without turning the XL profile into a promise of simultaneity.

Its aluminum heat exchanger and the declared modulation of 1:5 are accompanied by a seasonal efficiency of 94%. The reference 12016089 does not include control and is distinguished from the MiSet or SRT50/2 sets. The MiGo Link application solution is optional. The H-ES variant is exclusive for natural gas, without conversion to propane, and the A+ system class depends on a specific regulation combination.

The casing measures 740 x 418 x 300 mm, with a net weight of 31.6 kg and a service weight of 35.6 kg with water. The installation must maintain 300 mm above and below and allow for 600 mm of front access, in addition to the door clearance indicated for a cabinet. The 8 liters of the tank are for heating, not for domestic hot water. The maximum electrical consumption is 105 W at 230 V and the protection rating is IPX4D.

What is included in the purchase?

H-ES variant without control. Installation not included.

Price including VAT and shipping to mainland Spain. Installation, adaptations, and commissioning are valued separately.

Consult the manufacturer's PDFs ↓
Guide

What to check before installing this boiler

The choice of equipment does not replace the inspection of the installation by a qualified professional.

  1. Confirm the model and commercial reference, the type of gas, and the supply configuration in the manufacturer's documentation.
  2. Ask a qualified installer to assess the heating and domestic hot water demand; compare measured flow rates at the same temperature difference.
  3. Check dimensions, connections, flue gas evacuation, condensate drainage, and controls compatible with the existing installation.
  4. Confirm the included accessories and the delivery time before scheduling the installation. The online purchase of the equipment does not include installation or commissioning.
Technical data

Technical sheet: Saunier Duval Thelia Condens 25-A

Brand
Saunier Duval
Model
Saunier Duval Thelia Condens 25-A boiler
Status
New
Supply scope
H-ES variant without control. Installation not included.
Shipping
Included in mainland Spain. Please confirm the deadline.
Commercial reference
12016089

Specifications and dimensions of the model

Compare each magnitude under its testing conditions: heating, domestic hot water, efficiency, and dimensions.

Useful heating output (80/60 °C, G20)
5.0-18.1 kW
Heating
Useful heating output (50/30 °C, G20)
5.3-19.1 kW
Heating
Maximum heating power factory set (d.00)
15 kW
Heating
Supply temperature regulation
10-80 °C
Heating
Maximum heating pressure
3 bar
Heating
Nominal heating flow rate (ΔT 20 K)
779 l/h
Heating
Nominal heating flow rate (ΔT 30 K)
520 l/h
Heating
Heating expansion vessel
8 l; it is not a domestic hot water storage.
Heating
Useful power of DHW (G20)
5.0-25.2 kW
Hot water
Specific flow rate DHW D (ΔT 30 K, EN 13203)
12.1 l/min
Hot water
Domestic hot water flow rate (ΔT 25 K, inlet 10 °C)
14.6 l/min
Hot water
Specific flow rate for domestic hot water (ΔT 35 K)
10.4 l/min
Hot water
Continuous flow domestic hot water (ΔT 35 K)
622 l/h
Hot water
Domestic hot water flow limiter
8 l/min
Hot water
Permissible pressure of domestic hot water
0.3-10 bar
Hot water
Adjustment of domestic hot water temperature
35-60 °C
Hot water
Preparation of hot water
Warm Start
Hot water
Operating gas
Natural gas G20, 20 mbar; category I2H
Gas and construction
Propane conversion
Not available for this variant H-ES.
Gas and construction
Primary heat exchanger
Aluminum
Gas and construction
Control of the offered reference
Without control; MiSet and SRT50/2 packs with different references.
Regulation
Control via application
MiGo Link optional solution
Regulation
Dimensions (height x width x depth)
740 x 418 x 300 mm
Dimensions and installation
Net weight
31.6 kg
Dimensions and installation
Weight with water
35.6 kg
Dimensions and installation
Minimum superior distance
300 mm
Dimensions and installation
Minimum lower distance
300 mm
Dimensions and installation
Lateral clearance and disassembly
0 mm mounting; 50 mm for disassembling the side
Dimensions and installation
Front access and cabinet door
600 mm access; 5 mm in front of the door according to the plan
Dimensions and installation
Seasonal ErP efficiency
94 %
Efficiency and sound
Heating class with regulation
A with MiSet; A+ with MiPro Sense or external sensor and MiSet
Efficiency and sound
Domestic hot water efficiency and sanitary profile
A / XL
Efficiency and sound
Declared sound level
49 dB(A)
Efficiency and sound
Electrical supply
230 V, 50 Hz
Electricity
Maximum electrical consumption
105 W
Electricity
CE number (PIN)
0063CP3646
Gas and construction
Degree of protection
IPX4D
Electricity
Declared modulation ratio
1:5
Gas and construction
Manufacturer's sources

PDF and documentation of the model

Original documents, unmodified. Refer to the installation plan and the conditions of each data point before selecting the equipment.

The gallery sheets are summaries of Uniclima based on these documents. The external volume diagram does not represent connections, accessories, or service distances.

Frequently Asked Questions

Frequently asked questions: condensing boilers 12016089

Is the Thelia Condens 25-A suitable for a 100 m² apartment?
As an example, 100 m² with a supposed loss of 80 W/m² require 8 kW. The Thelia offers 5.0-18.1 kW useful at 80/60 °C, so that calculated load example falls within the range. The minimum also matters: a zone that demands 3 kW is below and can cause cycling. Square meters are not guaranteed; the installer must check losses, emitters, and usage by zones. The 25 in the name does not mean 25 kW of heating: in domestic hot water, it reaches 25.2 kW.
Does the Thelia 25 allow for two simultaneous showers in winter?
With an inlet temperature of 10 °C and water at 40 °C, a ΔT of 30 K is compared. The specific flow rate is 12.1 l/min, while two showers at 8 l/min require 16 l/min. The manual also indicates a domestic hot water limiter of 8 l/min, a different magnitude from the test. If the temperature difference rises to 35 K, the specific flow rate drops to 10.4 l/min. Two sustained showers cannot be guaranteed; pressure, mixers, inlet temperature, and domestic capacity must be assessed before making a choice.
Does the Warm Start micro-accumulation equate to a water tank?
The manufacturer refers to Warm Start as the preparation that reduces the wait for hot water. It is not equivalent to a domestic hot water accumulator with a useful reserve for multiple consumption points. The system uses a plate heat exchanger, and the 8-liter expansion vessel is for the heating circuit, not for stored water for showers. Having an XL sanitary profile does not guarantee simultaneity either. If you need a reserve, compare useful liters, recovery, and demand of an accumulation solution.
What free space does the Thelia 25 need inside a cabinet?
Its dimensions are 740 x 418 x 300 mm and it weighs 31.6 kg net, 35.6 kg with water. The plan requires 300 mm above and below. It allows 0 mm on the sides for installation, but removing one side requires 50 mm. It distinguishes 600 mm of front access and 5 mm in front of a cabinet door: it is not enough to just fit the body and close the furniture without access. It is necessary to check the drainage, connections, and support, even when replacing another boiler of similar dimensions.
Can I install the Thelia Condens 25-A in a house with propane?
This H-ES variant is only for natural gas G20; its conversion to propane is not available. It is not a fuel change that can be assumed during installation. Before purchasing for a property with LPG, select a device whose documentation and label authorize that gas. The inspection must be carried out by a qualified professional; sharing brand, power, or casing with another model does not demonstrate compatibility.
What is the difference between reference 12016089 and the packs with MiSet?
12016089 corresponds to the Thelia without control. MiSet wired, MiSet Radio, and SRT50/2 appear as sets with their own references. The MiGo Link module for application is optional and requires the appropriate configuration; it is not automatically included with this boiler. The A+ class advertised for certain combinations requires the specified control or sensor. Compare the specific content of the offer and not just the name Thelia before deciding between the unit and the pack.
Does the price include installation and shipping?
Includes VAT and shipping to mainland Spain. Installation and adaptations are valued separately. H-ES variant without control. Installation not included.

Other boilers for comparison

Shipping to the mainland includedConfirm the deadline before installation.
New equipmentModel and reference identified
Separate installationReview by a qualified professional
Informed purchaseCheck supply and documentation.
Saunier Duval Thelia Condens 25-A boiler