Vaillant ecoTEC exclusive VMW 30CF/1-7 SfI boiler
The ecoTEC exclusive VMW 30CF combines 30 kW for domestic hot water with modulating heating from 3.0 to 22.0 kW at 80/60 °C. Its specific flow rate is 14.3 l/min at ΔT 30 K. Micro-accumulation speeds up the response for domestic hot water in a body of 382 mm in depth; the recommendation for two bathrooms does not mean opening all the showers at the same time. With sensoCOMFORT radio and myVaillant. Installation not included. VAT and mainland shipping included.
- Heating power (80/60 °C)
- 3.0-22.0 kW
- Specific flow rate for domestic hot water (ΔT 30 K)
- 14.3 l/min
- Dimensions (height x width x depth)
- 720 x 440 x 382 mm
The model, at a glance
Vaillant ecoTEC exclusive 30CF: heating 3.0-22.0 kW at 80/60 °C, DHW 30.0 kW and specific flow rate 14.3 l/min at ΔT 30 K.
- Heating power (80/60 °C)
- 3.0-22.0 kW
- Specific flow rate for domestic hot water (ΔT 30 K)
- 14.3 l/min
- Dimensions (height x width x depth)
- 720 x 440 x 382 mm
Read the full description and what it includes.
The VMW 30CF is the lowest heating power option among these three ecoTEC exclusive models. It can reduce its output to 3.0 kW at 80/60 °C and reach 22.0 kW; at 50/30 °C, the range is from 3.4 to 23.9 kW. This allows for consideration of both cold days and periods of low demand, without choosing the boiler solely based on the number of bathrooms.
In domestic hot water, it offers 30.0 kW and 14.3 l/min specific at ΔT 30 K. The commercial figure of 17.2 l/min corresponds to ΔT 25 K, a lower temperature rise. Vaillant targets it for homes with two bathrooms and a kitchen, but two showers of 8 l/min with inlet water at 10 °C and outlet at 40 °C would exceed its specific flow rate in testing.
Its micro-accumulation improves the initial response when opening the tap without representing a large capacity tank. The sanitary limiter is 10.4 l/min and must be distinguished from the specific flow rate and the mixed flow rate of a shower. The result also depends on the inlet pressure and temperature, as well as simultaneous consumption.
With a height of 720 mm, a width of 440 mm, a depth of 382 mm, and a net weight of 41 kg, it shares the same format as the 36CF. The connection for air and exhaust is 60/100 mm. The installation space must allow for front access, lower space, and the upper clearance of the chosen duct; the dimensions of the body are not the same as the installed unit.
What is included in the purchase?
With sensoCOMFORT radio and myVaillant. Installation not included.
Price including VAT and shipping to mainland Spain. Installation, adaptations, and commissioning are valued separately.
What to check before installing this boiler
The choice of equipment does not replace the inspection of the installation by a qualified professional.
- Confirm the model and commercial reference, the type of gas, and the supply configuration in the manufacturer's documentation.
- Ask a qualified installer to assess the heating and domestic hot water demand; compare measured flow rates at the same temperature difference.
- Check dimensions, connections, flue gas evacuation, condensate drainage, and controls compatible with the existing installation.
- Confirm the included accessories and the delivery time before scheduling the installation. The online purchase of the equipment does not include installation or commissioning.
Technical data of Vaillant ecoTEC exclusive VMW 30CF/1-7 SfI boiler
- Brand
- Vaillant
- Model
- Vaillant ecoTEC exclusive VMW 30CF/1-7 SfI boiler
- Status
- New
- Supply scope
- With sensoCOMFORT radio and myVaillant. Installation not included.
- Shipping
- Included in mainland Spain. Please confirm the deadline.
- Commercial reference
- 125834627
Specifications and dimensions of the model
Compare each magnitude under its testing conditions: heating, domestic hot water, efficiency, and dimensions.
- Heating power G20 (80/60 °C)
- 3.0-22.0 kW
Heating - Heating power G20 (50/30 °C)
- 3.4-23.9 kW
Heating - Heating thermal load G20 (Hi)
- 3.2-22.4 kW
Heating - Adjustable flow temperature
- 30-80 °C
Heating - Maximum heating pressure
- 3 bar
Heating - Maximum power DHW G20
- 30.0 kW
Hot water - Nominal thermal load DHW G20 (Hi)
- 28.3 kW
Hot water - Specific flow rate D (ΔT 30 K, EN 13203-1)
- 14.3 l/min
Hot water - Declared domestic hot water flow rate (ΔT 25 K)
- 17.2 l/min
Hot water - Minimum starting flow rate
- 2.0 l/min
Hot water - Domestic hot water flow limiter
- 10.4 l/min
Hot water - Adjustable domestic hot water temperature
- 35-65 °C
Hot water - Allowed service pressure for domestic hot water
- 0.3-10 bar
Hot water - Required connection pressure for domestic hot water
- 0.7 bar
Hot water - Hot water system
- Mixed with micro-accumulation
Hot water - Dimensions (height x width x depth)
- 720 x 440 x 382 mm
Dimensions and installation - Net weight
- 41 kg
Dimensions and installation - Minimum lateral distance
- 5 mm on each side
Dimensions and installation - Minimum inferior distance
- 180 mm
Dimensions and installation - Minimum front service distance
- 500 mm
Dimensions and installation - Distance greater with duct 60/100
- 165 or 248 mm, according to the installation plan
Dimensions and installation - Maximum distance with duct 80/80
- 220 mm
Dimensions and installation - Maximum distance with duct 80/125
- 276 mm
Dimensions and installation - Natural gas connection pressure G20
- 20 mbar
Gas and connections - Gas connection on the appliance
- 15 mm
Gas and connections - Air connection and exhaust in the appliance
- 60/100 mm
Gas and connections - NOx emissions class
- 6
Gas and connections - Maximum electrical consumption in heating
- 55 W
Electricity - Maximum electrical consumption in domestic hot water
- 73 W
Electricity - Nominal power supply
- 230 V / 50 Hz
Electricity - Standby power consumption
- Less than 2 W
Electricity - Degree of protection
- IPX5D
Electricity
PDF and documentation of the model
Original documents, unmodified. Refer to the installation plan and the conditions of each data point before selecting the equipment.
- ecoTEC exclusive VMW installation manualPDF · 88 pages · VaillantView original on the manufacturer's website ↗
- ecoTEC exclusive technical sheetPDF · 2 pages · VaillantView original on the manufacturer's website ↗
The gallery sheets are summaries of Uniclima based on these documents. The external volume diagram does not represent connections, accessories, or service distances.