Wolf CGB-2K 20 boiler
The Wolf CGB-2K 20 (ref. 8615054) is a wall-mounted mixed condensing boiler: it provides heating and produces domestic hot water within the unit through an integrated stainless steel plate heat exchanger. Reference for the boiler alone. Control, connections, flue, and installation to be confirmed. VAT and mainland shipping included.
- Heating power (80/60 °C)
- 18.9 kW
- Specific flow rate for domestic hot water (ΔT 30 K)
- 10.3 l/min
- Dimensions (height x width x depth)
- 790 x 440 x 378 mm
The model, at a glance
Wolf CGB-2K 20: 18.9 kW of heating at 80/60 °C, instantaneous domestic hot water, and 790 x 440 x 378 mm. Technical data, comparison, and PDF in Spanish.
- Heating power (80/60 °C)
- 18.9 kW
- Specific flow rate for domestic hot water (ΔT 30 K)
- 10.3 l/min
- Dimensions (height x width x depth)
- 790 x 440 x 378 mm
Read the full description and what it includes.
The Wolf CGB-2K 20 (ref. 8615054) is a wall-mounted mixed condensing boiler: it provides heating and produces domestic hot water within the unit through an integrated stainless steel plate heat exchanger.
In heating, it delivers 18.9 kW of nominal thermal power at 80/60 °C and 20.4 kW at 50/30 °C. At 80/60 °C, the minimum modulating power is 3.8 kW with natural gas and 6.8 kW with LPG G31, so the selection must start from the calculated thermal load and the actual temperature of the installation.
DHW is produced when a tap is opened, without a storage tank. The normalized specific flow rate is 10.3 l/min at ΔT = 30 K; it should not be confused with the factory-adjusted flow rate, which ranges from 2.0 to 6.5 l/min. The DHW temperature is adjusted between 45 and 65 °C. The body measures 790 x 440 x 378 mm and the 10 l expansion vessel belongs to the heating system, it does not store water for showers.
What is included in the purchase?
Boiler reference only. Control, connections, exhaust and installation to be confirmed.
Price including VAT and shipping to mainland Spain. Installation, adaptations, and commissioning are valued separately.
What to check before installing this boiler
The choice of equipment does not replace the inspection of the installation by a qualified professional.
- Confirm the model and commercial reference, the type of gas, and the supply configuration in the manufacturer's documentation.
- Ask a qualified installer to assess the heating and domestic hot water demand; compare measured flow rates at the same temperature difference.
- Check dimensions, connections, flue gas evacuation, condensate drainage, and controls compatible with the existing installation.
- Confirm the included accessories and the delivery time before scheduling the installation. The online purchase of the equipment does not include installation or commissioning.
Technical data of Wolf CGB-2K 20 boiler
- Brand
- Wolf
- Model
- Wolf CGB-2K 20 boiler
- Status
- New
- Supply scope
- Boiler reference only. Control, connections, exhaust and installation to be confirmed.
- Shipping
- Included in mainland Spain. Please confirm the deadline.
- Commercial reference
- 8615054
Specifications and dimensions of the model
Compare each magnitude under its testing conditions: heating, domestic hot water, efficiency, and dimensions.
- Maximum useful power (80/60 °C)
- 18.9 kW
Heating - Maximum useful power (50/30 °C)
- 20.4 kW
Heating - Minimum power (80/60 °C, natural gas)
- 3.8 kW
Heating - Minimum power (80/60 °C, LPG G31)
- 6.8 kW
Heating - Maximum heating pressure
- 3 bar
Heating - Heating expansion vessel
- 10 l
Heating - Production of domestic hot water
- Instantaneous, without integrated domestic hot water accumulator
Hot water - Maximum useful power in domestic hot water
- 22.2 kW
Hot water - Specific flow rate of domestic hot water (ΔT 30 °C)
- 10.3 l/min
Hot water - Domestic hot water flow rate with factory limiter
- 2.0–6.5 l/min
Hot water - Adjustable domestic hot water temperature
- 45–65 °C
Hot water - Maximum domestic hot water pressure
- 10 bar
Hot water - Dimensions (height × width × depth)
- 790 × 440 × 378 mm
Dimensions and connections - Weight
- 35 kg
Dimensions and connections - Heating connections
- G 3/4 inches
Dimensions and connections - Domestic hot water connections
- G 3/4 inches
Dimensions and connections - Gas connection
- R 1/2 inch
Dimensions and connections - Concentric flue connection
- 60/100 mm
Dimensions and connections - Electrical supply
- 230 V / 50 Hz
Dimensions and connections - NOx emissions class
- 6
Efficiency and consumption - Standby power consumption
- 3 W
Efficiency and consumption - Maximum electrical consumption
- 63 W
Efficiency and consumption - Degree of protection
- IPX4D
Efficiency and consumption - Nominal ErP power (Prated)
- 19 kW
Efficiency and consumption - Heating energy class
- A
Efficiency and consumption - Seasonal heating efficiency
- 93 %
Efficiency and consumption - Domestic hot water load profile
- XL
Efficiency and consumption - Energy class of domestic hot water
- A
Efficiency and consumption - Efficiency of domestic hot water
- 85 %
Efficiency and consumption - Normalized annual heating consumption (QHE)
- 10568 kWh/year
Efficiency and consumption - Normalized annual fuel consumption in domestic hot water (AFC)
- 17 GJ/year
Efficiency and consumption - Sound power level indoors (LWA)
- 47 dB
Efficiency and consumption
PDF and documentation of the model
Original documents, unmodified. Refer to the installation plan and the conditions of each data point before selecting the equipment.
- CGB-2(K) technical brochurePDF · 32 pages · WolfView original on the manufacturer's website ↗
- Service instructions for the installer CGB-2/CGB-2KPDF · 108 pages · WolfView original on the manufacturer's website ↗
- Technical sheet: CGB-2K in accordance with Regulation (EU) 811/2013PDF · 2 pages · WolfView original on the manufacturer's website ↗
The gallery sheets are summaries of Uniclima based on these documents. The external volume diagram does not represent connections, accessories, or service distances.