Wolf FGB – K 24 boiler
The Wolf FGB-K 24 combines heating and instantaneous hot water in a body of 650 x 408 x 310 mm. It provides 19.4 kW useful at 80/60 °C and 23.3 kW useful in domestic hot water, with a specific flow rate of 10.55 l/min at ΔT 30 K. Equipment without installation; please confirm the accessories for this configuration. VAT and mainland shipping included.
- Heating power (80/60 °C)
- 19.4 kW
- Specific flow rate for domestic hot water (ΔT 30 K)
- 10.55 l/min
- Body (height x width x depth)
- 650 x 408 x 310 mm
The model, at a glance
Wolf FGB-K 24: 19.4 kW useful at 80/60 °C, instantaneous domestic hot water with 10.55 l/min specific at ΔT 30 K. Dimensions, comparison, and PDF in Spanish.
- Heating power (80/60 °C)
- 19.4 kW
- Specific flow rate for domestic hot water (ΔT 30 K)
- 10.55 l/min
- Body (height x width x depth)
- 650 x 408 x 310 mm
Read the full description and what it includes.
It is the lowest power variant of this family: it modulates from 4.8 kW useful at 80/60 °C to 19.4 kW, and reaches 20.7 kW at 50/30 °C. It is advisable to compare both the minimum and the maximum with the demand of the home; choosing number 24 does not replace the heating calculation.
Instantaneous production eliminates the need to reserve space for a domestic hot water tank. The specific flow rate of 10.55 l/min at ΔT 30 K allows for a comparison of its domestic hot water capacity with the 28 and 35 versions, but the result at the taps depends on the inlet temperature and the installation.
The compact body weighs 27 kg and features sanitary connections G 1/2, heating connections G 3/4, and an 8-liter heating expansion vessel. The basic digital control is part of the equipment; the WOLF LINK PRO remote control and the BM-2 control are accessories that must be selected separately. The dimensions of the body do not include all elements or installation clearances.
What is included in the purchase?
Equipment without installation. Please confirm the accessories for this configuration.
Price including VAT and shipping to mainland Spain. Installation, adaptations, and commissioning are valued separately.
What to check before installing this boiler
The choice of equipment does not replace the inspection of the installation by a qualified professional.
- Confirm the model and commercial reference, the type of gas, and the supply configuration in the manufacturer's documentation.
- Ask a qualified installer to assess the heating and domestic hot water demand; compare measured flow rates at the same temperature difference.
- Check dimensions, connections, flue gas evacuation, condensate drainage, and controls compatible with the existing installation.
- Confirm the included accessories and the delivery time before scheduling the installation. The online purchase of the equipment does not include installation or commissioning.
Technical data of Wolf FGB – K 24 boiler
- Brand
- Wolf
- Model
- Wolf FGB – K 24 boiler
- Status
- New
- Supply scope
- Equipment without installation; please confirm the accessories for this configuration.
- Shipping
- Included in mainland Spain. Please confirm the deadline.
Specifications and dimensions of the model
Compare each magnitude under its testing conditions: heating, domestic hot water, efficiency, and dimensions.
- Maximum useful power (80/60 °C)
- 19.4 kW
Heating - Maximum useful power (50/30 °C)
- 20.7 kW
Heating - Minimum power (80/60 °C)
- 4.8 kW
Heating - Minimum useful power (50/30 °C)
- 5.3 kW
Heating - Maximum heating pressure
- 3 bar
Heating - Heating expansion vessel
- 8 l
Heating - Production of domestic hot water
- Instantaneous, without integrated domestic hot water accumulator
Hot water - Maximum useful power in domestic hot water
- 23.3 kW
Hot water - Specific flow rate of domestic hot water (ΔT 30 °C)
- 10.55 l/min
Hot water - Adjustable domestic hot water temperature
- 30–65 °C
Hot water - Maximum domestic hot water pressure
- 10 bar
Hot water - Body dimensions (height x width x depth)
- 650 × 408 × 310 mm
Dimensions and connections - Weight
- 27 kg
Dimensions and connections - Heating connections
- G 3/4 inches
Dimensions and connections - Domestic hot water connections
- G 1/2 inch
Dimensions and connections - Gas connection
- G 1/2 inch
Dimensions and connections - Concentric flue connection
- 60/100 mm
Dimensions and connections - Electrical supply
- 230 V / 50 Hz
Dimensions and connections - NOx emissions class
- 6
Efficiency and consumption - Standby power consumption
- 2 W
Efficiency and consumption - Maximum electrical consumption
- 76 W
Efficiency and consumption - Degree of protection
- IPX4D
Efficiency and consumption - Maximum flow temperature (approx.)
- 85 °C
Heating - Minimum flow pressure for domestic hot water (EN 15502-2-2)
- 0.3 bar
Hot water
PDF and documentation of the model
Original documents, unmodified. Refer to the installation plan and the conditions of each data point before selecting the equipment.
- WOLF technical catalog 2026 · FGB-K 24PDF · 358 pages · WolfView original on the manufacturer's website ↗
The gallery sheets are summaries of Uniclima based on these documents. The external volume diagram does not represent connections, accessories, or service distances.