Saunier Duval Isofast F 28 E1 PCB Ref. S1019000

Saunier Duval Isofast F 28 E1 PCB Ref. S1019000

Stock · 5 units

Main PCB for Saunier Duval Isofast boilers (C/F 28 E1, C/F 35 E1) and Isomax (C 28 E2, F 28 E2). It includes the integrated circuit SDA 1586E CS.0168, a Myrra transformer with code 42430-2, three relays, and a 125mAT 250V fuse. The PCB code read from the silkscreen is 116011 F.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S1019000

PCB with reference S1019000. 11 verified compatibilities: C 28 E1 and C 28 E1 NOX.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval C 28 E1IsofastContrasted
Saunier Duval C 28 E1 NOxIsofastContrasted
Saunier Duval C 35 E1IsofastContrasted
Saunier Duval F 28 E1IsofastContrasted
Saunier Duval F 35 E1IsofastContrasted
Saunier Duval C 28 E2IsomaxContrasted
Saunier Duval C 28 E204IsomaxContrasted
Saunier Duval C 28 E205IsomaxContrasted
Saunier Duval F 28 E2IsomaxContrasted
Saunier Duval F 28 E204IsomaxContrasted
Saunier Duval F 28 E205IsomaxContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1019000 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1019000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB S1019000 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler is completely dead, not even a pilot light is on.

    Cause: A fault in the transformer or in the fuse of the PCB cuts off power to the rest of the circuit.

    Measure with a multimeter if the fuse on the PCB is blown before considering the board as lost.

  • 02

    It turns on for a moment and then turns off, repeating the cycle over and over again.

    Cause: The PCB aborts the startup at a specific point in the sequence due to an internal control fault.

    Check at what exact moment it cuts off, before the flame, with the flame, or when modulating, to determine if it is the PCB or another component.

  • 03

    The boiler control does not respond to temperature changes.

    Cause: The microcontroller on the PCB does not properly manage the signal received from the thermostat.

    Try another thermostat or bypass the demand to rule out that the fault is in the control and not in the PCB.

  • 04

    An error code appears that repeats after each reset attempt.

    Cause: The PCB detects a persistent internal fault and does not allow the ignition cycle to proceed.

    Note the code displayed before purchasing, to verify that it corresponds to a PCB fault according to your boiler's manual.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
13Main printed circuit board fault.The main PCB (S1019000) does not pass the internal self-diagnosis; this is usually due to an electronics/EEPROM fault or the PCB not generating its internal voltages. Check the 230 V input, fuse, and low voltages (5/15/24 V) on the PCB; if these are correct and the wiring is OK, replace the PCB.
20Communication fault between the user interface and the main PCB.Communication channel/ebus fault on the main board, incompatibility between interface and PCB or defective connection/harness. Check the interface power supply from the board, connectors/harness and test with a known interface; if it persists, the cause is the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S1019000 PCB.

Catalogue reference
S1019000
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

PCB code
116011 F
Main integrated circuit
SDA 1586E CS.0168
Transformer manufacturer
Myrra
Transformer code
42430-2
Fuse
125mAT 250V
Configuration table (headers)
FAB | SLT | FONC | VCD | RAD | CMS
Frequently Asked Questions

Frequently asked questions about the PCB S1019000

Is this PCB Ref. S1019000 suitable for an Isofast F 35 E1?
Yes, the data sheet covers Isofast C 28 E1, C 35 E1, F 28 E1, F 35 E1, and Isomax C 28 E2 and F 28 E2.
What integrated circuit does the PCB of the Saunier Duval Isofast F 28 E1 have?
The SDA 1586E CS.0168.
What fuse does this PCB from Isofast/Isomax use?
A 125mAT 250V fuse, along with three relays.

Spare parts related to Saunier Duval Isomax

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Isofast F 28 E1 PCB Ref. S1019000