Baxi Roca Circulating Pump RS 20/20 DYA43-15 P Ref. 122075100
Wet rotor circulator pump for the heating circuit of Baxi Roca boilers from the RS-20 and RSI-20/20 range. It pushes hot water to the radiators and operates at two speeds (60 W / 88 W). It is replaced when the boiler does not heat normally, makes noise in the pump, or does not start.
VAT included
Consult via WhatsAppBaxi Roca boilers compatible with reference 122075100
Circulating pump with reference 122075100. 12 verified compatibilities: RS 20/20 GN and RS 20/20 GP.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Baxi Roca RS 20/20 GN | Baxi Roca RS 20/20 | Contrasted |
| Baxi Roca RS 20/20 GP | Baxi Roca RS 20/20 | Contrasted |
| Baxi Roca RS 20/20 F | Baxi Roca RS 20/20 | Contrasted |
| Baxi Roca RS 20/20 T | Baxi Roca RS 20/20 | Contrasted |
| Baxi Roca RS 20/20 V0 | Baxi Roca RS 20/20 | Contrasted |
| Baxi Roca RS 20/20 V1 | Baxi Roca RS 20/20 | Contrasted |
| Baxi Roca RSI 20/20 GN | Baxi Roca RSI 20/20 | Contrasted |
| Baxi Roca RSI 20/20 GP | Baxi Roca RSI 20/20 | Contrasted |
| Baxi Roca RSI 20/20 V0 | Baxi Roca RSI 20/20 | Contrasted |
| Baxi Roca RSI 20/20 V1 | Baxi Roca RSI 20/20 | Contrasted |
| Baxi Roca RS 20 GN | Baxi Roca RS 20 | Contrasted |
| Baxi Roca RS 20 GP | Baxi Roca RS 20 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number 122075100 is the piece for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 122075100. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the circulator pump 122075100 resolves.
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The radiators do not heat evenly, some more than others, or they take longer than usual.
Cause: If the pump does not provide sufficient pressure at the selected speed, the water does not reach the more distant areas of the circuit properly.
Change the pump to the other speed and check if the heat distribution improves before declaring it faulty.
- 02
The boiler ignites and goes through its cycle, but the water does not seem to flow through the system.
Cause: The rotor may be blocked or the winding damaged, so it does not generate thrust even though the motor receives power.
Check if the pump body is hot and vibrates slightly when starting; if it is cold and without vibration, point to the pump before considering another cause.
- 03
A buzzing or strange noise can be heard in the pump area with the boiler running.
Cause: Air in the circuit, sediment, or a worn bearing causes the rotor not to spin smoothly and results in noticeable noise.
Bleed the air from the system using the nearest bleed valve and check that there is no visible scale in the fitting before replacing the pump.
- 04
The pump does not start or gets stuck, not rotating at any speed.
Cause: The wet rotor gets stuck if it has been idle for a long time, which is typical after the summer without heating, due to scale buildup on the shaft.
With the system depressurized and the pump unplugged, try to unlock the shaft with a screwdriver through the front slot before replacing it.
Fault codes for Baxi Roca that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 50-60-90 | Overtemperature thermostat open. | If the circulating pump is seized and there is no circulation, the primary overheats and triggers the klixon; check by bleeding the circuit and ensuring that the pump shaft rotates (unlock with a screwdriver) and that there is flow. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Baxi Roca circulator pump 122075100
- Catalogue reference
- 122075100
- Brand
- Baxi Roca
- Type of part
- Pumps
- Units in stock
- 7 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Nominal voltage
- 1~230V
- Frequency
- 50Hz
- Condenser
- 2.6 µF - 400V
- Thermal class
- F (TF110)
- Nominal pressure
- PN10
- Degree of protection
- IP42
- Power speed 1
- 60 W
- Power speed 2
- 88 W / 0.38 A
- Model
- DYA43-15 P
- Manufacturing code
- 4507338
- Place of manufacture
- Made in EU
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Baxi Roca RS 20/20 F manual (PDF)Document © Baxi Roca, provided as a technical reference.