Boiler fault code

Faults and fault codes of Saunier Duval IsoFast MiConnect

Saunier Duval IsoFast MiConnect MA 35-CS/1-Cf boiler

Identify the warning, do not guess the part.

If you Saunier Duval IsoFast MiConnect show a code, copy the complete message and check the model. Here you will find the warnings from its manual and what information to provide for a review. A code guides: it does not confirm by itself which spare part is needed.

Models and version of the manual

MA35-CS/1. The manual identifies MA35-CS/1 in N-ES and N-INT versions. It is not used for the different version MA36-CF/1.

Consulted edition: 0020294191_03 · 02/08/2022 · manufacturer's manualThe control options, accessories, and versions may limit which notifications appear in each installation.

Locate the code on your screen.

These accesses lead to their entry in the table. They are not a classification of the most common faults: the manual does not provide incidence statistics.

  1. F.022

    There is no water in the product, it is insufficient, or the water pressure is too low.

  2. F.028

    During the ignition phase, the flame signal was not detected.

  3. F.029

    The ignition failed due to lack of flame during operation.

  4. F.075

    The pressure jump at the start of the heating pump is too low.

What to do without opening the boiler

  1. Note what you see.

    Complete code, message, and pressure displayed by the equipment. Indicate whether it occurs when opening hot water, requesting heating, or in both cases.

  2. Identify the device.

    Take a photo of the screen and the identification accessible without disassembling anything. Brand, model, and version help avoid confusing tables from different ranges.

  3. Describe how it started.

    Determine whether the fault is continuous or intermittent and if there was a supply interruption or a recent intervention. If it reappears after a reset allowed by the user manual, do not chain resets.

Do not open the casing or manipulate gas, wiring, combustion, or flue gas outlet. If you smell gas, avoid flames and switches, leave the area, and notify the distributor's emergency service from a safe location; in case of immediate danger, call 112.

Documented codes table

The meaning of the warning is provided, not the repair operations reserved for qualified personnel. When the manufacturer groups several codes, the grouping is maintained; it is not interpreted as a range of numbers.

CodeWhat does · source indicate?
F.000The signal from the supply temperature sensor has been interrupted. PDF
F.001The signal from the return temperature sensor has been interrupted. PDF
F.002The signal from the domestic hot water temperature sensor has been interrupted. PDF
F.003The signal from the temperature sensor of the accumulator has been interrupted. PDF
F.010A short circuit has occurred in the supply temperature sensor. PDF
F.011A short circuit has occurred in the return temperature sensor. PDF
F.012The temperature sensor of the hot water connection is short-circuited. PDF
F.013A short circuit has occurred in the temperature sensor of the accumulator. PDF
F.020The safety temperature limiter (STB) interrupts the control of the gas valve. The gas valve has closed because the temperature of the supply or return temperature sensor has exceeded the maximum limit. PDF
F.022There is no water in the product, it is insufficient, or the water pressure is too low. PDF
F.023The temperature difference between the supply and return is excessive. PDF
F.024The temperature increase is too rapid. PDF
F.025The temperature of the combustion gases is too high. PDF
F.027A flame signal was detected and the burner is off. PDF
F.028During the ignition phase, the flame signal was not detected. PDF
F.029The ignition failed due to lack of flame during operation. PDF
F.032The fan speed is out of tolerance. PDF
F.035The air intake/exhaust duct is blocked. PDF
F.040The air excess factor is too low. PDF
F.042The coding resistor (in the wiring harness) or the gas group resistor (on the PCB if it exists) is not valid. PDF
F.044The ionization signal of the regulation electrode is too low. The drift adaptation has failed. PDF
F.047The signal from the domestic hot water temperature sensor at the outlet of the internal accumulator is not plausible. PDF
F.049The eBUS is short-circuited or two active eBUS sources have reversed polarity. PDF
F.057The combustion regulation has failed and so has the corresponding emergency mode. PDF
F.061ASIC or µController does not operate within the defined time limits. PDF
F.062The flame disconnection is detected with a delay. PDF
F.063EEPROM warns of an error during the read and write test. PDF
F.064The sensor signal could not be converted correctly. PDF
F.065The operating temperature range of an electronic component has been exceeded. PDF
F.067The flame controller is faulty. PDF
F.068The flame controller reports an unstable signal. PDF
F.070The device identification (DSN) is incorrect, missing, or does not match the coding resistance. PDF
F.071The supply temperature sensor records implausible values. PDF
F.072The temperature difference between the supply and return temperature sensors is not valid. PDF
F.073The water pressure sensor is short-circuited. PDF
F.074The signal from the water pressure sensor is interrupted. PDF
F.075The pressure jump at the start of the heating pump is too low. PDF
F.077A condensate pump or a flue gas non-return valve block the operation of the burner. PDF
F.078The control module is not supported by the device. PDF
F.080The cold water inlet temperature sensor in the internal storage tank is faulty. PDF
F.081The boost has failed. PDF
F.083When starting the burner, no increase in temperature is recorded, or an increase is recorded too slowly on the supply or return temperature sensor. PDF
F.084The temperature difference between the supply and return temperature sensor results in implausible values. PDF
F.085The NTC sensors are incorrectly mounted. PDF
F.087The ignition transformer is not connected to the PCB. PDF
F.088The electrical connection with the gas valve has been interrupted. PDF
F.089The integrated heating pump is not suitable for the appliance model. PDF
F.092The gas type change has not been completed correctly. PDF
F.095The stepper motor of the gas valve has reached the minimum allowed number of steps. PDF
F.096The stepper motor of the gas valve has reached the maximum allowed number of steps. PDF
F.105If the gas valve or the PCB is replaced along with the device interface, the gas valve deviation must be adjusted to match the current gas valve. PDF
F.194The power supply of the PCB is faulty. PDF
F.195The device has detected a significant undervoltage in the power supply. PDF
F.196The device has detected a significant overvoltage in the power supply. PDF
F.317The flow sensor signal in the domestic hot water circuit is not plausible. PDF
F.318The 3-way motorised valve is not moving. PDF
F.320The heating pump is blocked. The unlocking function has not been performed correctly. PDF
F.321The pump electronics are faulty. PDF
F.322The heating pump is overheating. The emergency operation has not been able to reduce the temperature. PDF
F.323The heating pump is running dry. PDF
F.324The electrical connection of the pumps has been interrupted. PDF
F.325The heating pump has a fault. PDF
F.326The hydraulic test of the sensor and the actuator has determined that at least two hydraulic components are not functioning. PDF
F.327Due to a domestic hot water circuit not connected, the minimum volumetric flow rate of the heating is limited. PDF
F.344The regulation electrode cannot continue to be used. PDF
F.346A hard ignition has been detected. The ignition has failed. PDF
F.363The EEPROM on the display warns of an error during the read and write test. PDF
F.707It is not possible to establish any communication between the display and the PCB. PDF
F.905Communication interface disconnected PDF

Is there a problem, but no fault code appears?

The absence of a warning does not rule out a fault. For a boiler that does not heat, does not deliver hot water, loses pressure, or operates intermittently, describe the symptom and the moment it occurs. Do not assume that the PCB, the pump, or a sensor is faulty without checking the equipment and the installation.

Request a review of the boiler. · Consult maintenance

Before requesting a repair

Does the code identify the spare part I need to buy?

No. A single warning can have multiple causes. The spare part reference requires identifying the appliance and confirming the fault; the code or a generic photograph is not sufficient.

Can it be reset again if the fault returns?

It is not advisable to chain resets. Follow only what is outlined for the user in your version's manual. A persistent or recurring lockout requires inspection.

When does it make sense to compare a new boiler?

When you have a diagnosis and a budget, compare repair, availability of the spare part, and replacement according to your installation. An isolated fault code does not justify changing the equipment.

See new boilers · Consult installation or replacement

The technical sheet of each product provides information on its price and availability. Installation is quoted separately depending on the case.

Documentation and other guides

Official manual of Saunier Duval IsoFast MiConnect · 0020294191_03 · 02/08/2022. The page references in the table correspond to the PDF viewer, whose numbering may differ from the printed version.