Boiler fault code

Faults and fault codes of Saunier Duval Thema Condens 25-A

Saunier Duval Thema Condens 25-A boiler

Identify the warning, do not guess the part.

If you Saunier Duval Thema Condens 25-A show a code, copy the complete message and check the model. Here you will find the warnings from its manual and what information to provide for a review. A code guides: it does not confirm by itself which spare part is needed.

Models and version of the manual

25-A. It corresponds to Thema Condens 25-A, not to Thema MiConnect CS/1. The manual also covers AS variants: accessory notifications depend on the installation.

Consulted edition: Thema Condens 25-A / AS25-A / AS30-A manufacturer's manualThe control options, accessories, and versions may limit which notifications appear in each installation.

Locate the code on your screen.

These accesses lead to their entry in the table. They are not a classification of the most common faults: the manual does not provide incidence statistics.

  1. F.22

    Safety shutdown: lack of water

  2. F.28

    Start-up fault: ignition failed

  3. F.29

    Operating fault: failed ignition attempts

  4. F.83

    Fault: temperature adjustment in the supply and/or return temperature sensors

What to do without opening the boiler

  1. Note what you see.

    Complete code, message, and pressure displayed by the equipment. Indicate whether it occurs when opening hot water, requesting heating, or in both cases.

  2. Identify the device.

    Take a photo of the screen and the identification accessible without disassembling anything. Brand, model, and version help avoid confusing tables from different ranges.

  3. Describe how it started.

    Determine whether the fault is continuous or intermittent and if there was a supply interruption or a recent intervention. If it reappears after a reset allowed by the user manual, do not chain resets.

Do not open the casing or manipulate gas, wiring, combustion, or flue gas outlet. If you smell gas, avoid flames and switches, leave the area, and notify the distributor's emergency service from a safe location; in case of immediate danger, call 112.

Documented codes table

The meaning of the warning is provided, not the repair operations reserved for qualified personnel. When the manufacturer groups several codes, the grouping is maintained; it is not interpreted as a range of numbers.

CodeWhat does · source indicate?
F.00Interruption of the inlet temperature sensor PDF
F.01Return temperature sensor interruption PDF
F.10Short circuit in the inlet temperature sensor. PDF
F.11Short circuit in the return temperature sensor PDF
F.13Short circuit of the accumulator sensor PDF
F.20Safety shutdown: temperature limiter PDF
F.22Safety shutdown: lack of water PDF
F.23Safety shutdown: excessive temperature variation PDF
F.24Safety shutdown: temperature rise too fast PDF
F.26Fault: gas valve not functioning PDF
F.27Safety shutdown: incorrect flame detection PDF
F.28Start-up fault: ignition failed PDF
F.29Operating fault: failed ignition attempts PDF
F.32Fault: fan PDF
F.42Resistance fault coding (probably in combination with F.70) PDF
F.49Fault: eBUS PDF
F.52Fault in the connection of the circulating flow sensor PDF
F.53Fault in the circulating flow sensor PDF
F.54Gas pressure fault (in combination with F.28/F.29) PDF
F.56Fault in the regulation of the circulating flow sensor PDF
F.57Fault during comfortable safety operation PDF
F.61Gas valve control fault PDF
F.62Gas valve fault. Disconnection delay PDF
F.63EEPROM fault PDF
F.64Electronic fault / NTC PDF
F.65Fault: PCB temperature PDF
F.67Fault: electronics/flame PDF
F.68Flame signal fault (unstable) PDF
F.70Invalid product code (DSN) PDF
F.71Fault of the heating flow temperature sensor PDF
F.72Fault in the inlet and return temperature sensors. PDF
F.73Water pressure sensor signal out of range (too low) PDF
F.74Water pressure sensor signal out of range (too low) PDF
F.77Fault in flue gas damper/condensate pump PDF
F.79Accumulator temperature sensor fault PDF
F.83Fault: temperature adjustment in the supply and/or return temperature sensors PDF
F.84Fault: temperature sensor difference between supply/return, not plausible. PDF
F.85Fault: incorrect installation of the inlet or return temperature sensor PDF
F.86Fault: floor contact PDF

Is there a problem, but no fault code appears?

The absence of a warning does not rule out a fault. For a boiler that does not heat, does not deliver hot water, loses pressure, or operates intermittently, describe the symptom and the moment it occurs. Do not assume that the PCB, the pump, or a sensor is faulty without checking the equipment and the installation.

Request a review of the boiler. · Consult maintenance

Before requesting a repair

Does the code identify the spare part I need to buy?

No. A single warning can have multiple causes. The spare part reference requires identifying the appliance and confirming the fault; the code or a generic photograph is not sufficient.

Can it be reset again if the fault returns?

It is not advisable to chain resets. Follow only what is outlined for the user in your version's manual. A persistent or recurring lockout requires inspection.

When does it make sense to compare a new boiler?

When you have a diagnosis and a budget, compare repair, availability of the spare part, and replacement according to your installation. An isolated fault code does not justify changing the equipment.

See new boilers · Consult installation or replacement

The technical sheet of each product provides information on its price and availability. Installation is quoted separately depending on the case.

Documentation and other guides

Official manual of Saunier Duval Thema Condens 25-A · Thema Condens 25-A / AS25-A / AS30-A manual. The page reference numbers in the table correspond to the PDF viewer, which may differ from the printed version.

Consult fault guides by brand and model. · Return to the blog

De la lectura a la acción

What do you need next?