Bimetallic Heat Exchanger Tube Finned For Laura, RS 20/20 - Ref. 122035010
The finned tube double heat exchanger for Laura, RS 20/20, transfers heat from the primary circuit to the domestic hot water instantly. When it fails, the water comes out lukewarm or shows fluctuating temperatures, in addition to reducing the flow of DHW. This heat exchanger is compatible with several models, including R-20/20 GC, R-20/20 GP, RS-20/20 GN, and of course, Laura. A technician must confirm through diagnosis whether it needs to be replaced when you notice these symptoms or if you experience issues with the hot water supply.
- Type of part
- Bithermic heat exchanger
- Status
- Refurbished
- Catalogue reference
- 122035010
- Warranty
- 1 year
Baxi Roca boilers compatible with reference 122035010
Bitermal heat exchanger with reference 122035010. 15 verified compatibilities: R-20/20 GC and R-20/20 GN.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Baxi Roca R-20/20 GC | R 20/20 | Contrasted |
| Baxi Roca R-20/20 GN | R 20/20 | Contrasted |
| Baxi Roca R-20/20 GP | R 20/20 | Contrasted |
| Baxi Roca R-20/20FF | R 20/20 | Contrasted |
| Baxi Roca R-20/20FP | R 20/20 | Contrasted |
| Baxi Roca R-20/20P | R 20/20 | Contrasted |
| Baxi Roca R-20/20FCLIMA | R 20/20 | Contrasted |
| Baxi Roca RS-20/20 GN | RS 20/20 | Contrasted |
| Baxi Roca RS-20/20 GP | RS 20/20 | Contrasted |
| Baxi Roca RS-20/20F | RS 20/20 | Contrasted |
| Baxi Roca RS-20/20T | RS 20/20 | Contrasted |
| Baxi Roca NR-15/20 GN | NR 15/20 | Contrasted |
| Baxi Roca NR-15/20 GP | NR 15/20 | Contrasted |
| Baxi Roca Victoria 20/20 | Victoria / Laura | Contrasted |
| Baxi Roca Laura | Victoria / Laura | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 122035010 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 122035010. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the double heat exchanger 122035010
The bivalent heat exchanger transfers heat to heating and domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The hot water comes out fine at first and then suddenly cools down a few seconds after opening the tap.
Cause: Limescale builds up in the finned coil, interrupting the heat exchange as water passes through.
Check if the cooling occurs when you open the tap or only after a few seconds; if it takes time, it may be that the fins are obstructed.
- 02
The performance of the domestic hot water has been gradually decreasing, not overnight.
Cause: The coil gradually becomes covered with scale with each use, unlike a sudden fault.
Check if the loss of performance of the domestic hot water has been occurring over months; that slow pattern indicates aging of the heat exchanger, not a breakage.
- 03
By touch, the area where the heat exchanger is mounted feels much hotter than the rest of the boiler body.
Cause: If the fins are covered with limescale, heat is not transferred well to the water and accumulates in the metal of the heat exchanger.
With the boiler stopped and cold, remove the inspection cover if you can and check if the fins are white or covered in scale.
- 04
The pressure of the heating circuit increases when using the domestic hot water.
Cause: The coil separates the two circuits with a single metal wall; if it is perforated, it allows the mains water to mix with the heating water.
Compare the pressure on the manometer with the domestic hot water tap closed and then open; a clear increase indicates that there is a passage between circuits.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: heat exchanger Baxi Roca 122035010
- Catalogue reference
- 122035010
- Uniclima internal SKU
- IBCRRS2020
- Brand
- Baxi Roca
- Type of part
- Bithermic heat exchanger
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days