Sealed Combustion Chamber Vaillant ecoTEC Plus 5-5 (Giannoni GM30-45-004-11) — Ref. GM30-45-004-11
RefurbishedVaillantCombustion chambersGiannoni

Sealed Combustion Chamber Vaillant ecoTEC Plus 5-5 (Giannoni GM30-45-004-11) — Ref. GM30-45-004-11

Stock · 1 unit

Refurbished sealed combustion chamber set with primary condensing heat exchanger Giannoni GM30-45-004-11 for Vaillant ecoTEC plus boilers. It forms the combustion envelope and transfers heat to the heating circuit. Check compatibility by reading the label on your original chamber.

VAT included

Guide

How to check if the reference GM30-45-004-11 is the part for your boiler.

What determines it is not the boiler model, but the reference printed on the part you already have installed.

Diagnosis and fault codes

Symptoms and faults that the GM30-45-004-11 combustion chambers solve.

Common symptoms and faults

  • 01

    It heats up very quickly and then locks out (F.23/F.24)

    Cause: Primary heat exchanger blocked by sludge/deposits or air in the circuit

    Measure ΔT supply/return, bleed, check the dirt separator/return filter, and the actual flow rate of the pump.

  • 02

    Boiling noises (kettling) on demand

    Cause: Internal incrustation in the primary coil

    Check water hardness, inspect the primary circuit, and assess controlled chemical cleaning.

  • 03

    Condensate drips or corrosion marks on the casing

    Cause: Primary perforation or fatigued joints

    Visual inspection of the casing and condensate collector; check the siphon/funnel and tightness.

  • 04

    Frequent F.22/F.75 lockouts after bleeding.

    Cause: Insufficient circulation due to partial blockage of the primary or persistent air.

    Repeated bleeding, checking the pressure sensor, and flow testing; if it persists, clean/replace the primary.

  • 05

    Smell of gas or traces of soot on the casing

    Cause: Loss of tightness in the chamber

    Check the cover gasket and screws; replace single-use gaskets and perform combustion/leak test.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.22Lack of water or pressure too low in the circuitFill up to ~1.5 bar, bleed the system, check for leaks and the pressure sensor. If the issue persists, check circulation and the condition of the primary heat exchanger for possible obstruction.
F.23Lockout due to excessive temperature difference between supply/returnComplete bleeding, check the pump, filters/deaerator, and flow rate. A dirty or clogged primary can cause an abnormal ΔT; consider cleaning or replacement.
F.24Safety disconnection due to overheatingCheck the opening of valves, circulation, air in the circuit, and the condition of the heat exchanger. If the flow is insufficient due to deposits, clean or replace the primary.
F.28Flame is not detected during ignition.Although it is usually associated with gas/ignition, a chamber without tightness or with obstructed condensate drainage can affect combustion. Check the chamber gasket, siphon, and flue gas evacuation.
F.75Insufficient pressure change when starting the pumpFill/bleed, check pressure sensor and pump. A hydraulic blockage in the heat exchanger may prevent pressure increase; inspect and clean/replace.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the combustion chambers Vaillant GM30-45-004-11

Catalogue reference
GM30-45-004-11
Brand
Vaillant
Type of part
Combustion chambers
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Type of part
Sealed combustion chamber with primary condensing heat exchanger (assembly)
Component manufacturer
Giannoni France
Component reference
GM30-45-004-11
Observed identifiers
Customer n° 901041; it may appear as 11.10.41.02404 / 102404T3 on the label.
Intended application
Vaillant ecoTEC plus boilers with Giannoni chamber/heat exchanger; confirm by the equipment part's PCB.
Include
Chamber body + primary heat exchanger (according to unit). Does not include fan, cover, burner, or gaskets unless expressly stated.
Status
Refurbished
Before purchasing
  • Cut off gas and electrical supply and allow to cool down before intervening.
  • Complete bleeding of the heating circuit and the condensate siphon after installation.
  • Use new single-use gaskets in the chamber, blower, and condensate collector (e.g., 0020025929).
  • Tighten the cross of the chamber cover according to the torque specified in the model manual.
  • Gas tightness test and combustion verification after the change (adjust CO₂ if necessary)
  • Do not manipulate if you do not have accreditation; risk of gas and CO leakage.
  • Do not confirm compatibility based on commercial references: the component's PCB is the authority.
Frequently Asked Questions

Frequently asked questions about the combustion chambers GM30-45-004-11

Is it compatible with my Vaillant ecoTEC plus VMW 246/5-5?
Only if your original chamber has a GIANNONI PCB with Part n° GM30-45-004-11 and the geometry matches. No conclusive OEM cross-reference for Vaillant has been found for this reference; please verify it on your equipment and in the parts list.
Does it include fan, cover, burner, or gaskets?
No. It is the assembly of the chamber + heat exchanger. The fan, cover, burner, and gaskets must be ordered separately and always installed new or in good condition according to their breakdown.
What faults of the boiler are related to this part?
F.22, F.23, F.24, and F.75 due to flow/overtemperature/obstruction issues. F.28 may be affected if the chamber loses tightness or there is poor drainage of condensate.
Does it require parameterization after the change?
It usually does not require changes to the DSN or other parameters. However, it is mandatory to verify combustion, tightness, and hydraulic bleeding according to the installation manual.
Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Sealed Combustion Chamber Vaillant ecoTEC Plus 5-5 (Giannoni GM30-45-004-11) — Ref. GM30-45-004-11