Fagor Contract CA / FA 20 Flow Switch (MU1288400)

Fagor Contract CA / FA 20 Flow Switch (MU1288400)

25 €VAT includedIn stock · 1 unit

Flow detector (flow switch) installed in the domestic water circuit of Fagor boilers, which detects the opening of the tap to activate the burner and produce hot water. It should be replaced if the boiler does not start when hot water is requested or if the supply is intermittent. The manufacturer and part reference are not specified; only its compatibility with the indicated Fagor models is known.

Spare parts related to Fagor FA series 20

Compatibility

Fagor boilers compatible with reference MU1288400

Flow meter with reference MU1288400. Five confirmed compatibilities with two independent sources: CA 20 E N and CA 20 GLP. Verify the printed reference on your part before purchasing.

Compatibility confirmed

Boiler modelFamilyVerification
Fagor CA 20 E NFagor Contract CA (atmospheric)Confirmed · 2 sources
Fagor CA 20 LPGFagor Contract CA (atmospheric)Confirmed · 2 sources
Fagor FA 20 NFagor FA series 20Confirmed · 2 sources
Fagor FA 20 E2 NFagor FA series 20Confirmed · 2 sources
Fagor FA 23 EBFagor FA series 20Confirmed · 2 sources

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. MU1288400 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Locate the reference printed on the body of the flow meter you have installed: it should indicate MU1288400.
  2. Check your boiler model on the nameplate and look for it in the list of compatible models on this page.
  3. Compare the connections and the body with the original part before installing.
  4. If you have any doubts, send us a photo of the screen printing via WhatsApp and we'll confirm it for you before you purchase.
Diagnosis

Symptoms and faults resolved by flow meter MU1288400

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

When opening the hot water tap, the boiler remains silent: you don't hear the burner ignite.

Cause: Without the signal from the flow detector, the control unit doesn't know there is a demand for domestic hot water and doesn't initiate ignition.

Bleed a little air from the circuit and check that the flow at the tap is normal, not just a drip, before replacing the part.

The hot water comes and goes, as if someone were turning the tap on and off even though no one is touching it.

Cause: The water flow through the detector may not be stable enough to keep the contact closed, causing the boiler to turn the burner on and off in a loop.

Note if the problem improves when you open the tap more; if the low flow is the trigger, the detector is the main suspect.

There is plenty of mains pressure, but the boiler does not produce hot water at any tap in the house.

Cause: A fault in the main flow switch prevents the domestic hot water from starting up throughout the installation, even though the rest of the boiler's functions are working fine.

Confirm that the fault occurs with all the taps and not just one, to rule out a specific issue with that outlet.

The symptom worsens over time: before it took a while to provide hot water, and now it doesn't provide it at all.

Cause: The internal mechanism of the detector gradually seizes up due to lime or dirt until it stops activating.

If you noticed an increasing delay in turning on before it completely failed, it's advisable to check it with the part disassembled before declaring it dead.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Fagor MU1288400 flow meter datasheet

OEM reference
MU1288400
Brand
Fagor
Type of part
Flow Detectors
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days
Before purchasing
  • The manufacturer of this part is not listed: there is no text or legible marking on any visible part.
  • The code or reference of the component is not known; check the physical part before ordering it.
  • The current catalog of this sheet uses the reference MU1288400 and the name 'Fagor Contract CE 20E 1N', but this audit cannot confirm them: they do not appear in the photos nor do they have an independent source.
  • The boiler brand (Fagor) is identified by the nomenclature of compatible models, not by markings on the part itself.
  • There is no technical data established for this part.
Frequently Asked Questions

Frequently Asked Questions about Flow Meter MU1288400

Is this flow switch suitable for my Fagor CE-20E/1 N?
Yes, that model is on the list of boilers compatible with this part Ref. MU1288400.
Is it the same part that comes factory-installed on the Fagor FA-15/20 GLP?
The manufacturer is not listed on the part; it cannot be confirmed if it is original or compatible.
What differentiates this part Ref. MU1288400 from other Fagor flow switch cards with the same reference?
They share reference MU1288400, but each datasheet covers a different list of compatible Fagor models; it's advisable to check that your exact model is included in this list.
Why is there no hot water coming from my Fagor FA-20T/1 GLP when I turn on the tap?
It could be due to a fault in this flow detector, among other causes; it's also advisable to check the network pressure.
What is the factory reference for this flow switch for the Fagor FA-20ET/1 N?
There is no reference or readable code on the part; it cannot be specified.
Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model