Fagor PCB N03A000A2 · CI932404 for FE 24/27/35 EMA and FEE 24/26/27/35/40 MA

Fagor PCB N03A000A2 · CI932404 for FE 24/27/35 EMA and FEE 24/26/27/35/40 MA

Compatibility confirmed for the listed Fagor models. It is the control board for the Fagor boilers FE 24/27/35 EMA and FEE 24/26/27/35/40 MA, including the FEE 35 MA. The fault code F-5 ("Control board fault") indicates that if there is an internal fault in the electronic circuit, the boiler will lock out.

internal SKU
PLC319
Warranty
1 year
VAT included Stock · 4 units
Compatibility

Compatible models

Check the listed models, version and part number before ordering the spare part.

Verified compatibility

Boiler modelFamilyVerification
Fagor FEE 24 MAFagorVerified
Fagor FEE 26 MAFagorVerified
Fagor FEE 27 MAFagorVerified
Fagor FEE 35 MAFagorVerified
Fagor FEE 40 MAFagorVerified
Fagor FE 24 EMAFagorVerified
Fagor FE 27 EMAFagorVerified
Fagor FE 35 EMAFagorVerified
Fagor FE-24EMA NFagorVerified

Models pending verification

These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.

Fagor FEE 35 PLFagorUnconfirmed
Fagor FEE 35 PLATFagorUnconfirmed
Fagor FEE 35 MA UKFagorUnconfirmed
Fagor AOSMITH JLG24-EB, JLG27-EB and JLG35-EBFagorUnconfirmed

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Look for the code N03A000A2 on the label and the one for the PCB, REMCO CI932404. Some write NO3A000A2, with the letter O.
  2. Look at the Toshiba microcontroller: our two PCBs use TMP87PH46N and TMP87PH40N under the same N03A000A2.
  3. Check the encapsulated transformer: 230 V · 50/60 Hz and secondary 150 V · 1 mA (Avisor 1123535 or E130/10.5).
  4. Confirm on the rating plate that your boiler is a FE 24, 27 or 35 EMA or a FEE 24, 26, 27, 35 or 40 MA.
  5. If they match, call us at 911 17 77 77 with the model of your boiler. Any questions? Send us a photo of your part's label and the data plate from Contact.
Diagnosis and fault codes

Symptoms and checks

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    Fault code F-5 "Control board fault" in a Fagor FE 35 EMA

    Cause: Fault table from the manual: "If there is an internal fault in the electronic circuit, the boiler will lock." It does not mention N03A000A2.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Technical data

Uniclima internal SKU
PLC319
Brand
Fagor
Type of part
PCBs (control boards)
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
Depending on the country; cost shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Schaffner filter marking
250VAC / 50-60Hz / 2x27mH; filter only
Inventory — Avisor Transformer E130/10.5
primary 230 V, 50-60 Hz; T 70 °C; secondary 150 V, 1 mA
Inventory — Specified technical data
Toshiba TMP87PH40N microcontroller; marking JAPAN 0450E?I; D00862AD
Inventory — Application indicated in inventory
FE-24EMA N
Additional data — Schaffner RN242-1.4-02 network filter.
1.4 A · vertical mounting on PCB · TE Connectivity (RN242-1.4-02-27M)
Additional data — Filter: differences between
Source document: 250 VAC on both boards and 14 A on one. TE: 300 VDC (product datasheet) and 300 VAC nominal (series). · TE Connectivity
Identification — Marked code
CI932404
Identification — Marked code
REMCO
Identification — Marked code
N03A000A2
Identification — Marked code
RN242-1,4-02
Schaffner filter marking
250VAC / 50-60Hz / 2x27mH; filter only
Inventory data — Avisor E130/10.5 transformer
primary 230 V, 50-60 Hz; T 70 °C; secondary 150 V, 1 mA
Inventory data — Indicated technical data
Toshiba TMP87PH40N microcontroller; marking JAPAN 0450E?I; D00862AD
Inventory data — Application indicated in inventory
FE-24EMA N
Before purchasing
  • To confirm: Fagor FEE 35 PL: it is listed as FEE 35 PLAT-1 GLP (912011904), without determining if it is the same model.
  • To confirm: Fagor FEE 35 PLAT: (FEE-35PLAT/1N, 912011888) and (FEE 35 PLAT-1 N, 912011888)
  • Fagor FEE 35 MA UK
  • To confirm: AOSMITH JLG24-EB, JLG27-EB and JLG35-EB:
  • Do not confuse: 288.34.0010 — Fagor control circuit for FEE 35 MA, FEE 35 PL, FEE 26 MA and other models in this sheet — This sheet adds "C.O. NO3A000A2" without explaining the acronym. Just one: take it as a clue, not to ask.
  • add 99BN761 next to the model FEE-35MA-N and it doesn't specify what it is.
  • Board, codes, and 9 confirmed boilers. At least they link N03A000A2 with these models; we have not found the manufacturer's parts list.
Frequently asked questions

Frequently asked questions

How do I identify the Fagor N03A000A2 PCB?
Look for N03A000A2 on the board and the printed circuit code: REMCO CI932404, confirmed. They also catalog it as FAGN03A000A2 and FAN03A000A2; it is also written as NO3A000A2, with an O.
Is it compatible with my Fagor FE 24 EMA or FEE 35 MA?
Yes. Confirmed: for the FE 24, 27 and 35 EMA, the FE-24EMA N and the FEE 24, 26, 27, 35 and 40 MA. In addition, 4 are given for each one (3 for the FE-24EMA N), for example.
Is it compatible with the Fagor FEE 35 PL or the FEE 35 MA UK?
The FEE 35 PL is provided. Registered application: FEE 35 PLAT with number 912011904, but it is not clear that it is the same model. On the pages we have been able to read, the FEE 35 MA UK appears; another one could not be opened. None of the two have been confirmed. To verify, call us at 911 17 77 77 or send us a photo of your rating plate from Contact.
Does the same PCB work for the /1 B, /1 N, and /1 GLP versions?
The source documentation records the listed models without specifying version B or GLP (the FE-24EMA N is recorded as N). Several commercial product listings list those versions under N03A000A2, each with its 9-digit number, for example FE 24 EMA-1 B (912011227) and FE 35 EMA-1 GLP (912011361). Compare the full model on your nameplate.
What do N03A000A2, CI932404, TMP87PH46N, and TMP87PH40N mean?
N03A000A2 is the code for the Fagor PCB. REMCO CI932404 marks the printed circuit board. TMP87PH46N and TMP87PH40N are Toshiba microcontrollers: each of our two boards has one, with the same N03A000A2. The datasheets we have read do not explain the difference; the datasheet for the TMP87PH40N could not be read. Compare the chip marking.
What does the F-5 fault code of a Fagor FE 35 EMA indicate?
The manual for the FE 35 EMA refers to it as "Control board fault": with an internal fault in the electronic circuit, the boiler locks out. It does not mention the N03A000A2.
Who should install the PCB N03A000A2?
A qualified technician: the transformer on the PCB is marked 230 V · 50/60 Hz and the board controls a gas boiler.
Delivery to the EU in 2–6 working days Depending on the country; cost shown at checkout
1-year warranty inspected and tested
14-day return uninstalled parts
Technical support we verify your model
Fagor PCB N03A000A2 · CI932404 for FE 24/27/35 EMA and FEE 24/26/27/35/40 MA