The Saunier Duval Themafast F 24 E Display Module is a control PCB that manages the ignition, burner modulation, pump, and safety features of the boiler. When faults occur, the boiler may fail to start, lock out, or operate erratically. Users may notice fault codes such as F11, F12, F13, or F18. This module is compatible with boilers from the Themafast range, including the Themafast C 24 E model, among others. It should be replaced when the mentioned symptoms or associated fault codes are detected.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S1017200

PCB with reference S1017200. Two confirmed compatibilities: Themafast C 24 E and Themafast F 24 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Themafast C 24 EThemafastContrasted
Saunier Duval Themafast F 24 EThemafastContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part S1017200 is the one for your boiler.

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1017200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB S1017200 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The screen does not display anything, not even when turning on the boiler.

    Cause: This module generates the visible image on the control panel; if it fails, there is no indication even though the boiler operates internally.

    Check that the boiler is actually on and heating (pump noise, hot water) to rule out that the fault is with the main PCB and not with the display.

  • 02

    The screen is visible, but incomplete: segments, lines, or parts of the icons are missing.

    Cause: A fault in the display module or its connection to the main PCB leaves parts of the display unrefreshed.

    Check the flat cable or connector that connects the display module to the main PCB before replacing the module.

  • 03

    The + and - buttons do not change the temperature or any adjustable value.

    Cause: These keys are part of the display module; if the internal contact wears out, the press is not transmitted.

    Try pressing with different pressure or several times in a row: if it sometimes responds, it is a contact issue with the button, not with the boiler.

  • 04

    The manual/reset button does nothing when pressed, not even with the boiler in fault.

    Cause: The reset is executed through this module; if the contact of that key fails, the command never reaches the main PCB.

    Try resetting by cutting off and restoring the main power to the boiler: if it resets this way, the fault is in the button, not in the PCB.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F13Main PCB faultYes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB.
F11No signal is reaching the main circuitPossible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB.
F12No signal from the user interfaceNormally not — it's usually the display or its cable, not this main PCB.
F18User interface faultNormally not — it corresponds to the panel/display, not to this PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S1017200 PCB.

Catalogue reference
S1017200
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB S1017200

Is this display module with reference S1017200 compatible with any Saunier Duval boiler?
Yes, it is compatible with the Themafast C 24 E and Themafast F 24 E models.
When should I consider replacing the display module in a Themafast boiler?
You should change it when the screen shows nothing or the +, - or manual/reset buttons stop responding.
What keys are included in the display module of the Saunier Duval Themafast F 24 E?
Include a frame and three buttons: +, hand/reset, and -.
What fault codes are relevant for this display module?
The documented fault codes are F13, F11, F12, and F18.
What is the reference for the display module for the Themafast range?
The reference for the display module is PEDMTF24E.
How many models are compatible with the display module S1017200?
A total of 2 models are compatible: Themafast C 24 E and Themafast F 24 E.

Spare parts related to Saunier Duval Themafast

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Themafast F 24 E Display Module Ref. S1017200