Ferroli Domicompact F24 Air Pressure Switch Honeywell Ref. C6065F1241:2

Ferroli Domicompact F24 Air Pressure Switch Honeywell Ref. C6065F1241:2

Stock · 1 unit

Honeywell air pressure switch, code C6065F1241:2, for Ferroli boilers from the Domicompact/Domina/Domitop/New Elite F24-F30 series. It switches at a pressure of 1.65 mbar (max. 6 mbar) and cuts ignition if the extractor does not generate the necessary draft. It is replaced when the boiler locks due to draft or extraction failure.

VAT included

Compatibility

Ferroli boilers compatible with reference 39805631

Pressure switch with reference 39805631. Five confirmed compatibilities: Domina F24E and Domina F30E.

Proven compatibility

Boiler modelFamilyVerification
Ferroli Domina F24EDominaContrasted
Ferroli Domina F30EDominaContrasted
Ferroli Domitop DGT F30EDomitopContrasted
Ferroli New Elite F24New EliteContrasted
Ferroli Domicompact F24DomicompactContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 39805631 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 39805631. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 39805631 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler gets locked due to a draft or flue extraction fault.

    Cause: The pressure switch must close the contact when it reaches its switching pressure. If it does not, the control board locks the unit.

    Check that the pressure switch pressure ports are not blocked and that the silicone tubes are not hanging down.

  • 02

    The fan starts normally but the burner never ignites.

    Cause: Without the pressure switch signal, the control board does not allow the gas valve to open for safety reasons.

    Check that the fan does not have any rubbing noise and is not spinning slower than usual before replacing the pressure switch.

  • 03

    The display shows an error related to the air pressure switch.

    Cause: It is the code that the control board displays when it does not detect the pressure switch contact closure within the expected time.

    Check the wiring and connector of the pressure switch, as they sometimes come loose due to vibration, before replacing the part.

  • 04

    It has been experiencing intermittent ignition faults for some time, not always on the same day.

    Cause: A contact that starts to fail due to wear may work well at times and poorly at others.

    Note if the fault always occurs when cold or also when hot; it helps to distinguish the pressure switch from an extractor problem.

Fault codes for Ferroli that this part resolves.

CodeFaultDiagnosis and solution
F4Operation of the air pressure switch.The air pressure switch remains closed when it should open (stuck contact or tubes/venturi improperly connected/blocked). Check with a multimeter that it opens when the fan stops and inspect pressure tubes and air/smoke ducts.
F5Operation of the air pressure switch.The pressure switch does not close within the time (~55 s) after activating the fan due to lack of depression/draught or a defective pressure switch. Check closure with a multimeter when starting the fan and inspect the venturi, pressure tubes, and possible obstruction in air/smoke.
F6Operation of the air pressure switch.The pressure switch contact remains closed after several start-up attempts, indicating a stuck APS or reversed connection. Measure opening/closing with a multimeter and check the correct connection of the tubes to the pressure switch and the operation of the fan.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for Ferroli pressure switch 39805631

Catalogue reference
39805631
Brand
Ferroli
Type of part
Pressure switches
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
Honeywell
Honeywell code
C6065F1241:2
Switching pressure
P=1.65 mbar
Maximum pressure
max. 6 mbar
Voltage
250V~
Contact current
1.5(0.5)µ (unit not clear on the label)
CE code
CE-0063AP3085/1
Date/lot code
0204F
Place of manufacture
MADE IN CHINA
Frequently Asked Questions

Frequently asked questions about the pressure switch 39805631

Who manufactures the pressure switch for the Ferroli Domicompact F24?
Honeywell; the code recorded on the part is C6065F1241:2.
At what pressure does the pressure switch of the Domicompact F24 switch?
At 1.65 mbar, with a maximum pressure of 6 mbar.
Is this pressure switch suitable for a Ferroli Domina Oasi F24?
Yes, the Domina Oasi F24 is on the list of compatible boilers.

Spare parts related to Ferroli Domina

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model