Honeywell Air Pressure Switch C4065FH1131:2 Ferroli Domi Compact F24
Honeywell air pressure switch, model C4065FH1131:2, for Ferroli boilers from the Domi Compact, Domiproject, Divatech, Divatop H, and New Elite ranges. It switches at a pressure of 1.10 mbar, with a maximum supported pressure of 6 mbar. It is replaced when the boiler does not ignite, locks with an air or combustion fault, or the fan runs without the burner starting.
VAT included
Consult via WhatsAppFerroli boilers compatible with reference I39817510
Pressure switch with reference I39817510. Six confirmed compatibilities: Domicompact F24 and Domicompact F24E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ferroli Domicompact F24 | Ferroli Domicompact | Contrasted |
| Ferroli Domicompact F24E | Ferroli Domicompact | Contrasted |
| Ferroli Domicompact F30 | Ferroli Domicompact | Contrasted |
| Ferroli Domicompact C24 | Ferroli Domicompact | Contrasted |
| Ferroli Domiproject F24 | Ferroli Domiproject | Contrasted |
| Ferroli Domiproject F32 | Ferroli Domiproject | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. I39817510 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference I39817510. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure switch I39817510 resolves.
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler's fan works well, but the burner never ignites.
Cause: If the pressure switch does not close the contact, the control board does not allow gas to pass, even if the fan is generating sufficient pressure.
Check that the pressure switch electrical connector is properly connected to the PCB and that there are no loose wires before replacing it.
- 02
The boiler locks out with an air or combustion fault warning when trying to ignite.
Cause: The pressure switch may remain with the contact open if the internal microswitch is worn out, and the boiler thinks there is no draft.
Check that the silicone tube is properly connected to its inlet in the flue duct, as this is often the most common cause before the part fails.
- 03
It doesn't turn on and no clear fault code appears on the screen.
Cause: Some models only display a generic safety lock without indicating that the problem is in the air circuit.
Check that the flue duct is not blocked by nests, ice, or dirt at the outlet before replacing the pressure switch.
- 04
The fault only appears during the first starts of the day, when it is cold.
Cause: Condensation in the pressure intake pipes can be more pronounced when the boiler has been idle for several hours.
Check in the morning, before the first ignition, if there is water accumulated in the silicone tubes of the pressure switch.
Fault codes for Ferroli that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F5 | The air pressure switch does not work when the fan is turned on. | The air pressure switch should activate when the fan starts, but it doesn't. This could be due to a fault in its diaphragm or microswitch, or because it is not receiving the proper pressure from the fan. Check for continuity at its terminals when starting the fan. Also, inspect the silicone tube, the venturi, and whether the flue is blocked. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Datasheet for Ferroli pressure switch I39817510
- Catalogue reference
- I39817510
- Brand
- Ferroli
- Type of part
- Pressure switches
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Model
- C4065FH1131:2
- Contacts
- 1.5(0.5)µ 250V~ (character printed like this on the label, possible A for amperes)
- Switching pressure
- P=1.10 mbar
- Maximum pressure
- max. 6 mbar
- Date/lot code
- 0511F
- CE Certificate
- CE-0063AP3085/1
- Place of manufacture
- Made in China
- Micro switch model
- V-562QR-047
- Current and voltage of the microswitch
- 1.8A-250VAC
- Micro switch code
- VI70
- Date/batch of the microswitch
- 0500F
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Ferroli Domiproject F24 Manual (PDF)Document © Ferroli, provided as a technical reference.