Fagor FEB-23E Circulating Pump Wilo RS15/5-3 Ref. 4518919
Wilo RS15/5-3 circulating pump, with three speeds, for Fagor FEB-23E boilers and related models. Operates at 230V/50Hz, up to PN6 pressure, with three rotational speeds (1600, 2000, and 2200 min-1). It is replaced when the boiler does not heat properly, the pump makes noise, gets blocked, or leaks water from the seal.
VAT included
Consult via WhatsAppFagor boilers compatible with reference 4511685
Circulating pump with reference 4511685. Two confirmed compatibilities: FEB-23E and FEB-23E N.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FEB-23E | Ecomini | Contrasted |
| Fagor FEB-23E N | Ecomini | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 4511685 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 4511685. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the circulator pump 4511685 resolves.
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler is working, the burner ignites, but the heating is not heating properly.
Cause: The water in the circuit does not circulate at the necessary rate because the pump rotor is spinning poorly or not spinning at all.
Switch between the three speeds of the pump and see if you notice any change in temperature in the radiators.
- 02
The pump makes noise or vibrates noticeably.
Cause: There may be air in the circuit or a worn internal bearing.
Bleed the heating circuit and check if the noise disappears before replacing the pump.
- 03
The water does not circulate through the heating circuit even though the boiler is on.
Cause: This occurs because the pump does not move the necessary flow due to blockage or internal fault.
Touch the body of the pump with the heating requesting heat: if you don't feel any vibration, it is likely not spinning.
- 04
The pump gets stuck after a long time without using the heating.
Cause: Lime and debris from the circuit stick to the rotor when the pump is stopped for several weeks or months.
Try to unlock the shaft manually with a screwdriver through the rear screw of the motor before replacing it.
- 05
Water is leaking from the pump seal, next to the motor shaft.
Cause: The mechanical seal that prevents leaks through the shaft wears out and begins to lose tightness.
Dry the area and check after a while of operation if the leak reappears right at the body of the pump.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Fagor 4511685 circulation pump.
- Catalogue reference
- 4511685
- Brand
- Fagor
- Type of part
- Pumps
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Type
- RS15/5-3
- Wilo code
- 4518919
- Voltage
- 230V 50Hz
- Condenser
- 2.6uF - 400VDB
- Nominal pressure
- PN6
- Degree of protection
- IP44
- Insulation class
- Class F - TF95
- Speeds
- III 2200min-1/0.37A/84W; II 2000min-1/0.27A/60W; I 1600min-1/0.18A/42W
- Date code (label)
- 10W37