Wilo RS15/5-3 Circulating Pump Motor - Fagor FE-30E/1B and Compatible Models - Ref. 4511885
RefurbishedFagorPumpsWilo

Wilo RS15/5-3 Circulating Pump Motor - Fagor FE-30E/1B and Compatible Models - Ref. 4511885

Stock · 1 unit

Wilo RS15/5-3 circulator pump motor, identified by the factory label, for the indicated Fagor boilers. It operates at three speeds (2200, 2000, and 1600 min⁻¹) with powers of 84, 60, and 42 W and a capacitor of 2.6 µF, thermal class F. Two readings from the label (voltage and degree of protection) are uncertain due to blurriness.

VAT included

Compatibility

Fagor boilers compatible with reference ST0005502

Circulating pump with reference ST0005502. Six confirmed compatibilities: CE-30E/1B and CE-30E/1N.

Proven compatibility

Boiler modelFamilyVerification
Fagor CE-30E/1BFagor Contract MiniContrasted
Fagor CE-30E/1NFagor Contract MiniContrasted
Fagor FE-30E/1BFagor Contract MiniContrasted
Fagor FE-30E/1NFagor Contract MiniContrasted
Fagor FE27EFagor Contract MiniContrasted
Fagor FEB-24AR/1NFagor Contract MiniContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. ST0005502 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference ST0005502. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the circulator pump ST0005502 resolves.

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The burner ignites but the radiators do not heat or heat very little.

    Cause: The pump does not move enough water through the circuit even though the boiler produces heat.

    Check if the pump is spinning and vibrating when touched with the boiler running before declaring it faulty.

  • 02

    Noise or buzzing in the pump area

    Cause: Worn bearing or trapped air in the circuit causes the motor to vibrate.

    Bleed the heating circuit and see if the noise disappears.

  • 03

    The pump does not start or does not rotate, especially after a long period of inactivity.

    Cause: The shaft has seized due to deposits accumulated during inactivity.

    Try turning the shaft by hand with a screwdriver in the front slot before replacing it.

  • 04

    There is dripping or moisture appearing around the motor shaft.

    Cause: The mechanical seal has lost its tightness.

    Dry the area and check in cold if the humidity reappears right there and not in a nearby joint.

  • 05

    The pump buzzes and takes time to start, or starts with difficulty.

    Cause: The start capacitor has lost capacity and the motor is not gaining momentum.

    Check if the pump makes a prolonged buzzing sound before starting, indicating forced start.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Fagor ST0005502 circulation pump.

Catalogue reference
ST0005502
Brand
Fagor
Type of part
Pumps
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
Wilo
Wilo model
RS15/5-3
Wilo part number
4511885
Casting number
4513777
Thermal class
Class F - TF55
Speed/current/power
2200 min-1: 0.37A / 84W | 2000 min-1: 0.27A / 60W | 1600 min-1: 0.18A / 42W
Date/batch
2004
Before purchasing
  • Two readings on the PCB are uncertain due to blurriness: the voltage (possibly ~230V instead of ~26V) and the protection rating (PH8-IF44). Please confirm them in your unit.
Frequently Asked Questions

Frequently asked questions about the circulator pump ST0005502

Is this Wilo RS15/5-3 pump compatible with the Fagor FE-30E/1B?
Yes, it is one of the Fagor boilers indicated: CE-30E/1B, CE-30E/1N, FE-30E/1B, FE-30E/1N, FE27E, and FEB-24AR/1N.
Who manufactures the motor of this pump from the Fagor FE-30E/1B?
Wilo, model RS15/5-3, according to the factory label.
How many speeds does the RS15/5-3 pump of the Fagor FE-30E/1B work at?
Three: 2200, 2000 and 1600 min⁻¹, with 84 W, 60 W and 42 W respectively.
What capacitor does the Wilo RS15/5-3 pump of the Fagor FE-30E/1B use?
A 2.6 µF capacitor, with thermal class F, according to the label.

Spare parts related to Fagor Fagor Contract Mini

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Wilo RS15/5-3 Circulating Pump Motor - Fagor FE-30E/1B and Compatible Models - Ref. 4511885