Grundfos UP 15-60/SD Pump · P/N 59716503

Grundfos UP 15-60/SD Pump · P/N 59716503

Grundfos UP 15-60/SD circulator pump, reference 59716503. Power supply 230 V~ · 50 Hz and power 110 W.

Type of part
Circulator pump
Catalogue reference
05732500
Warranty
1 year
VAT included Stock · 6 units
Compatibility

Saunier Duval boilers compatible with reference 05732500

Spare part referenced as 05732500 in the Saunier Duval catalog, with 13 verified applications in the following models from the Isofast, Isotwin, and Isomax ranges:

Verified compatibility

Boiler modelFamilyVerification
Saunier Duval Isofast F 35 ESaunier DuvalVerified
Saunier Duval Isofast F 35 E1Saunier DuvalVerified
Saunier Duval Isofast C 35 ESaunier DuvalVerified
Saunier Duval Isofast C 35 E1Saunier DuvalVerified
Saunier Duval Isofast C 31 ESaunier DuvalVerified
Saunier Duval Isofast C 31 E1Saunier DuvalVerified
Saunier Duval Isofast F 31 ESaunier DuvalVerified
Saunier Duval Isofast F 31 E1Saunier DuvalVerified
Saunier Duval Isotwin C 28 EASaunier DuvalVerified
Saunier Duval Isotwin F 28 EASaunier DuvalVerified
Saunier Duval Isotwin F 24 EASaunier DuvalVerified
Saunier Duval Isomax C 28 E2 (after the number 0500612151)Saunier DuvalVerified
Saunier Duval Isomax F 28 E2 (after the number 0500612151)Saunier DuvalVerified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 05732500 is the part for your boiler

Before requesting the spare part, check the correspondence between the label of the installed motor, the hydraulic body, and the PCB of your boiler:

  1. Compare the complete model UP 15-60/SD and the P/N 59716503 from your pump's label.
  2. Check the spare part reference 05732500 and the specific application for your boiler in the table.
  3. In Isomax C 28 E2 and F 28 E2, the application corresponds to units after the number 0500612151.
  4. Compare the shape of the hydraulic body, the connections, and the electrical connector with the photographs in the gallery.
Diagnosis and fault codes

What to check before replacing the circulator pump 05732500?

Common symptoms and faults

  • 01

    Insufficient heating or temperature lockout

    Cause: Poor circulation can raise the temperature of the circuit. A closed valve, a sensor, or the three-way valve may also be involved.

    The diagnosis must distinguish the flow of the circuit and the operation of the pump before replacing it.

  • 02

    The pump is buzzing but does not start the circulation.

    Cause: In the Isofast F 35 E1, the manual lists a blocked pump or a faulty capacitor among the causes of overheating.

    A technician must check the motor-condenser assembly; the noise alone does not identify the faulty part.

  • 03

    The boiler stops with fault code F.23 or F.24 when the temperature rises too quickly.

    Cause: Blocked pump or low power, or air in the circuit.

    Bleed the system and have a technician check the circulation pump.

  • 04

    The boiler stops with fault code F.22: there is not enough water in the circuit.

    Cause: Low water in the circuit or faulty water pressure sensor.

    Fill the water circuit. If it happens again, have a technician check the pressure sensor.

  • 05

    The boiler stops with fault code 05: overheating.

    Cause: Possible air in the system, faulty pump or obstruction.

    Have a technician check it. If the water is not circulating, the pump is suspect.

  • 06

    The boiler stops with fault code 21: lack of water in the system.

    Cause: Pressure below 0.5 bar: lack of water or leak.

    Fill with the blue key until about 1-1.2 bar. If it drops again, have a technician check it.

  • 07

    The boiler stops with a warning of low water or low pressure, and the pressure drops again after refilling.

    Cause: Low water in the circuit, faulty pressure sensor, or loose wire from the pump or sensor.

    Check the cold pressure and the cables. If the pressure drops again, have a technician look for leaks.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
Isofast F 35 E1Overheating circuitThe manual includes blocked pump, faulty condenser, closed valves, overheating thermostat, and presence of air among the causes. It does not equate on its own to a defective pump.
14 · Isofast F 35 E / F 35 E1Temperature limitationThe table includes faulty pump, domestic hot water sensor, three-way valve, and insufficient heating flow. It requires differentiating those causes.
05Overheating safety: the bimetallic thermostat of the boiler has tripped, which has a manual reset.If it repeats, check that there is water in the system and that the pump is circulating. If it is not circulating, point to the pump. Have a technician check it.
F.22Stopped due to lack of water in the circuit or due to incorrect reading from the water pressure sensor.Code with a dot, typical of the Isofast Condens; the old Isofast models use numbers. With the boiler cold, check the pressure gauge: if the pressure is low, refill; if not, the sensor or the cable to the pump are suspect.
F.23Safety shutdown due to excessive temperature variation: the pump may be blocked or underpowered, or there is air in the circuit.Code with a dot, typical of the Isofast Condens. If the boiler stops again while heating, it points to the pump: have a technician check it.
F.24Safety shutdown due to too rapid temperature rise: pump blocked or with low power, or air in the circuit.Code with a dot, typical of the Isofast Condens. Just like the F.23: if it repeats, have a technician check the pump and the air in the circuit.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval 05732500 circulation pump.

MPN verified on the label
59716503
Catalogue reference
05732500
Uniclima internal SKU
BCIF35E1
Brand
Saunier Duval
Type of part
Circulator pump
Units in stock
6 units
Status
Refurbished
Warranty
1 year
Shipping
Depending on the country; cost shown at checkout
Return
14 days

Part data and available documentation

Compare the electrical data and the references of the Grundfos front panel with those of the pump installed in your boiler:

Component manufacturer
Grundfos
Model
UP 15-60/SD
PCB reference
59716503
Power supply
230 V~ · 50 Hz
Rated power
110 W
Indicated current
0.45 A
Protection and class
IP44 · TF95 · class H · max. 6 bar
Condenser
2,5 µF
Additional marking on PCB
0535SAU
Spare part reference for verification
05732500
Frequently asked questions

Frequently asked questions about the circulator pump 05732500

Which reference should I compare?
The P/N 59716503 corresponds to the Grundfos PCB. Also check the spare part reference 05732500 and the revision of the unit indicated in its parts list.
Delivery to the EU in 2–6 working days Depending on the country; cost shown at checkout
1-year warranty inspected and tested
14-day return uninstalled parts
Technical support we verify your model
Grundfos UP 15-60/SD Pump · P/N 59716503