TCL cassette set: illustration of the range, not to scale

TCL cassette air conditioning M18S1S3 · 4.70 kW

1.010,59 €VAT included

4042 frigorías/h from the ceiling, with a 650 × 650 mm panel included. Single-phase.

1/4″ / 3/8″ · Monofásica · body 245 mm de alto · precarga 5 m What to consider

VAT and shipping included. Installation not included. Availability and delivery time to be confirmed.

Availability to be confirmed
Components and supply

What does the TCL M18S1S3 include?

Cassette Set 1×1: components grouped according to the TCL table.

ModelComponentSupply scope
MN18SS3Cassette indoor unit
570 × 245 × 570 mm · 14.5 kg
1 included
MT1813Outdoor unit
853 × 602 × 349 mm · 30 kg
1 included
NPAN60S1Cassette panel
650 × 57 × 650 mm
1 included

Wireless remote control included as per catalog; wired remote control not included. Installation, pipes, supports, wiring, and commissioning are quoted separately.

Cover: illustrative composition of the range, not to scale. The official photographs of the indoor unit are shared among capacities. Check the references and dimensions of this set.

Guide

What to check before installing TCL M18S1S3

The choice of equipment does not replace the inspection of the installation by a qualified professional.

  1. Check the cassette body and the NPAN60S1 panel separately. The dimensions of the panel do not match the ceiling cutout; ensure access to drainage and maintenance.
  2. Tubería 1/4″ / 3/8″. Precarga para 5 m; recorrido máximo 25 m y desnivel 10 m. La carga adicional por metro debe comprobarse en el manual exacto. El instalador debe contrastar placa y revisión antes de intervenir.
  3. The set is single-phase. The installer will check the voltage of the PCB, the protections, the wiring, and the ventilation distances.
  4. Wireless remote included as per catalog; does not include wired remote.
Technical data

TCL M18S1S3

Brand
TCL
Model and composition
TCL M18S1S3
Supply scope
MN18SS3 + MT1813 + NPAN60S1
Installation
Not included
Availability and transport
VAT and shipping included. Installation not included. Confirm availability and delivery time.

Specifications and dimensions of the model

Capabilities, consumption, efficiency, noise, and dimensions of this pair. The testing conditions and climate are part of each value.

Set
M18S1S3
Set and power supply
Indoor unit
MN18SS3
Set and power supply
Outdoor unit
MT1813
Set and power supply
Type
1×1 cassette · cooling and heating
Set and power supply
Power supply
220 V · single-phase
Set and power supply
Nominal power in cold conditions
4.70 kW
Power and efficiency
Approximate nominal cooling capacity
4042 frigorías/h
Power and efficiency · Conversion: kW × 860.
Nominal heat output
4.70 kW
Power and efficiency
Energy class in cold
A++
Power and efficiency
Energy class in heating
A+
Power and efficiency
Interior · width × height × depth
570 × 245 × 570 mm
Measures to prepare the installation
Net internal weight
14.5 kg
Measures to prepare the installation
Net external weight
30 kg
Measures to prepare the installation
Panel
NPAN60S1
Measures to prepare the installation
Panel · published dimensions
650 × 57 × 650 mm
Measures to prepare the installation
Exterior · width × height × depth
853 × 602 × 349 mm
Medidas para preparar la instalación · TCL, ficha del modelo actual; coincide con la tabla de conductos MT1813.
Pipe · liquid / gas
1/4″ / 3/8″
Pipe and refrigerant
Refrigerant
R32
Pipe and refrigerant
Factory published load
0.96 kg
Pipe and refrigerant · Catalog data; check the revision plate provided.
SEER
6,1
Eficiencia, consumo y circulación de aire
SCOP · average climate
4
Eficiencia, consumo y circulación de aire
External sound power
65 dB(A)
Eficiencia, consumo y circulación de aire · Potencia sonora, no presión sonora.
Potencia sonora interior · S/H/M/L/silencio
56/53/48/42/38 dB(A)
Eficiencia, consumo y circulación de aire · Potencia sonora, no presión sonora.
Caudal de aire interior
750 m³/h
Eficiencia, consumo y circulación de aire
Tubería cubierta por la precarga
5 m
Límites para preparar la instalación · Catálogo TCL 2026 Portugal, página PDF 12; no es el recorrido máximo.
Maximum range
25 m
Límites para preparar la instalación · Tabla oficial TCL Europa para esta referencia.
Maximum slope
10 m
Límites para preparar la instalación · Entre las unidades interior y exterior.
Before purchasing
  • Data from the linked documentation for the indicated reference. Check the PCB and the installation manual of the supplied revision before sizing gaps, connections, or refrigerant charge. The images are not assembly diagrams.

Documentation

Frequently Asked Questions

Questions about TCL M18S1S3

How many frigorías does the TCL M18S1S3 have?
Approximately 4042 frigorías/h, based on 4.70 kW nominal in cooling. This is thermal capacity, not electrical consumption.
What does the set include?
Indoor unit cassette MN18SS3, outdoor unit MT1813, cassette panel NPAN60S1. Wireless remote control included as per catalog; wired remote control not included.
What pipe do you need?
Tubería 1/4″ / 3/8″. Precarga para 5 m; recorrido máximo 25 m y desnivel 10 m. La carga adicional por metro debe comprobarse en el manual exacto. El instalador debe contrastar placa y revisión antes de intervenir.
Are the dimensions of the panel the ceiling opening?
No. The NPAN60S1 panel measures 650 × 57 × 650 mm, but the space and clearances are taken from the installation plan of the unit.
Is it single-phase or three-phase?
It is single-phase. Check the voltage of the PCB and protections with the installer.
Can I buy it with installation?
The price includes VAT and shipping costs. Installation is quoted separately based on location, route, and necessary work. Check availability and lead time before placing the order.

Services for your air conditioning

TCL cassette air conditioning M18S1S3 · 4.70 kW