TCL cassette air conditioning M30S1S2 · 8.79 kW
7559 frigorías/h from the ceiling, with a 950 × 950 mm panel included. Single-phase.
3/8″ / 5/8″ · Monofásica · body 245 mm de alto · precarga 5 m What to consider
VAT and shipping included. Installation not included. Availability and delivery time to be confirmed.
What does TCL M30S1S2 include?
Cassette Set 1×1: components grouped according to the TCL table.
| Model | Component | Supply scope |
|---|---|---|
| MN30SS2 | Cassette indoor unit 840 × 245 × 840 mm · 24,0 kg | 1 included |
| MT3012 | Outdoor unit 845 × 700 × 342 mm · 41 kg | 1 included |
| NPAN90S1 | Cassette panel 950 × 950 × 45 mm | 1 included |
The reference and supply of the control unit are confirmed in the quote. Installation, piping, supports, wiring, and commissioning are budgeted separately.
Cover: illustrative composition of the range, not to scale. The official photographs of the indoor unit are shared among capacities. Check the references and dimensions of this set.
What to check before installing TCL M30S1S2
The choice of equipment does not replace the inspection of the installation by a qualified professional.
- Check the cassette body and the NPAN90S1 panel separately. The dimensions of the panel do not match the ceiling cutout; ensure access to drainage and maintenance.
- Tubería 3/8″ / 5/8″. Precarga para 5 m; longitud máxima equivalente 35 m y desnivel 20 m. Por encima de 5 m: 25 g/m adicionales. El instalador debe contrastar placa y revisión antes de intervenir.
- The set is single-phase. The installer will check the voltage of the PCB, the protections, the wiring, and the ventilation distances.
- The reference and the supply of the control are confirmed in the budget.
TCL M30S1S2
- Brand
- TCL
- Model and composition
- TCL M30S1S2
- Supply scope
- MN30SS2 + MT3012 + NPAN90S1
- Installation
- Not included
- Availability and transport
- VAT and shipping included. Installation not included. Confirm availability and delivery time.
Specifications and dimensions of the model
Capabilities, consumption, efficiency, noise, and dimensions of this pair. The testing conditions and climate are part of each value.
- Set
- M30S1S2
Set and power supply - Indoor unit
- MN30SS2
Set and power supply - Outdoor unit
- MT3012
Set and power supply - Type
- 1×1 cassette · cooling and heating
Set and power supply - Power supply
- 220 V · single-phase
Set and power supply - Nominal power in cold conditions
- 8.79 kW
Power and efficiency - Approximate nominal cooling capacity
- 7559 frigorías/h
Power and efficiency · Conversion: kW × 860. - Nominal heat output
- 9.38 kW
Power and efficiency - Energy class in cold
- A++
Power and efficiency - Energy class in heating
- A+
Power and efficiency - Body · published dimensions
- 840 × 840 × 245 mm
Measures to prepare the installation · Body without panel; confirm dimensions and space in the installation plan. - Exterior · width × height × depth
- 845 × 700 × 342 mm
Measures to prepare the installation - Net internal weight
- 24.0 kg
Measures to prepare the installation - Net external weight
- 41 kg
Measures to prepare the installation - Panel
- NPAN90S1
Measures to prepare the installation - Panel · published dimensions
- 950 × 950 × 45 mm
Measures to prepare the installation - Pipe · liquid / gas
- 3/8″ / 5/8″
Pipe and refrigerant - Refrigerant
- R32
Pipe and refrigerant - Factory published load
- 1.40 kg
Pipe and refrigerant · Catalog data; check the revision plate provided. - SEER
- 6,2
Eficiencia, consumo y circulación de aire - SCOP · average climate
- 4
Eficiencia, consumo y circulación de aire - Consumo nominal en frío
- 2790 W
Eficiencia, consumo y circulación de aire · Potencia eléctrica nominal, no capacidad térmica. - Consumo nominal en calor
- 2730 W
Eficiencia, consumo y circulación de aire · Potencia eléctrica nominal, no capacidad térmica. - External sound power
- 66 dB(A)
Eficiencia, consumo y circulación de aire · Potencia sonora, no presión sonora. - Potencia sonora interior · S/H/M/L/silencio
- 61/57/53/50/48 dB(A)
Eficiencia, consumo y circulación de aire · Potencia sonora, no presión sonora. - Caudal de aire interior
- 1600 m³/h
Eficiencia, consumo y circulación de aire - Tubería cubierta por la precarga
- 5 m
Límites para preparar la instalación · Catálogo TCL 2026 Portugal, página PDF 12; no es el recorrido máximo. - Longitud máxima equivalente
- 35 m
Límites para preparar la instalación · Catálogo oficial TCL Italia 2026, página PDF 58. Longitud equivalente, no solo tubo recto. - Maximum slope
- 20 m
Límites para preparar la instalación · Entre las unidades interior y exterior. - Longitud mínima recomendada
- 3 m
Límites para preparar la instalación · Catálogo oficial TCL Italia 2026. - Carga adicional por encima de 5 m
- 25 g/m
Límites para preparar la instalación · Dentro de los límites permitidos. Confirmar placa y revisión; intervención de profesional habilitado. - Interior · width × height × depth
- 840 × 245 × 840 mm
Dimensiones de la unidad interior · Orden de ejes aclarado por el catálogo oficial TCL Italia 2026.
- Datos de la documentación enlazada para la referencia indicada. Verifica la placa y el manual de instalación de la revisión suministrada antes de dimensionar huecos, conexiones o carga de refrigerante. Las imágenes no son planos de montaje. Algunas cotas, pesos o cargas difieren entre el catálogo 2025–2026 y la ficha TCL actual. Confirma la revisión y su plano antes de preparar la instalación.