Boiler fault code

Faults and fault codes of Ferroli Bluehelix Hitech RRT C

Ferroli Bluehelix Hitech RRT 24 C boiler

Identify the warning, do not guess the part.

If you Ferroli Bluehelix Hitech RRT C show a code, copy the complete message and check the model. Here you will find the warnings from its manual and what information to provide for a review. A code guides: it does not confirm by itself which spare part is needed.

Models and version of the manual

24 °C, 28 °C and 34 °C. The table corresponds to the Hitech RRT C range. The 45 H version has its own guide and manual; it is also not extrapolated to Bluehelix Pro or Tech RRT.

Consulted edition: 3541V300 · Rev. 00 · 02/2021 · manufacturer's manualThe control options, accessories, and versions may limit which notifications appear in each installation.

Locate the code on your screen.

These accesses lead to their entry in the table. They are not a classification of the most common faults: the manual does not provide incidence statistics.

  1. A01

    The burner does not ignite

  2. F37

    Incorrect water pressure in the system

  3. F05

    Fan fault

  4. F64

    Exceeded the maximum number of consecutive resets

What to do without opening the boiler

  1. Note what you see.

    Complete code, message, and pressure displayed by the equipment. Indicate whether it occurs when opening hot water, requesting heating, or in both cases.

  2. Identify the device.

    Take a photo of the screen and the identification accessible without disassembling anything. Brand, model, and version help avoid confusing tables from different ranges.

  3. Describe how it started.

    Determine whether the fault is continuous or intermittent and if there was a supply interruption or a recent intervention. If it reappears after a reset allowed by the user manual, do not chain resets.

Do not open the casing or manipulate gas, wiring, combustion, or flue gas outlet. If you smell gas, avoid flames and switches, leave the area, and notify the distributor's emergency service from a safe location; in case of immediate danger, call 112.

Documented codes table

The meaning of the warning is provided, not the repair operations reserved for qualified personnel. When the manufacturer groups several codes, the grouping is maintained; it is not interpreted as a range of numbers.

CodeWhat does · source indicate?
A01The burner does not ignite PDF
A02Flame signal present with burner off PDF
F05Fan fault PDF
A06No flame after the ignition phase PDF
F15 – A07High flue gas temperature PDF
A08Overtemperature protection operation PDF
A09Intervention protection heat exchanger PDF
F09Overtemperature protection operation PDF
F10Return sensor anomaly PDF
F11Return sensor anomaly PDF
A11Gas valve connection PDF
F12Domestic hot water sensor anomaly PDF
F13Flue sensor anomaly PDF
A14Operation of the flue gas safety device PDF
F34Supply voltage below 180 V PDF
F35Incorrect power supply frequency PDF
A23 / A24 / A26 / F20 / F21 / F40 / F47 / F51Anomaly of the pressure switch or water pressure measurement PDF
F37Incorrect water pressure in the system PDF
F39Outdoor sensor anomaly PDF
F19Anomaly in the parameters of the control board PDF
F50 – F53Limit thermostat anomaly with parameter b06 = 1 or 4 PDF
F64Exceeded the maximum number of consecutive resets PDF
F62Calibration request PDF
A88Specific faults related to combustion control or the gas valve PDF
F65 – F98Specific combustion control faults PDF
A65 – A97Specific combustion control faults PDF
A98Too many SW errors or error appeared due to card replacement PDF
A99Generic fault PDF
F96Specific combustion flame errors PDF
A44Error due to multiple demands PDF
A80False flame signal after the gas valve closure PDF

Is there a problem, but no fault code appears?

The absence of a warning does not rule out a fault. For a boiler that does not heat, does not deliver hot water, loses pressure, or operates intermittently, describe the symptom and the moment it occurs. Do not assume that the PCB, the pump, or a sensor is faulty without checking the equipment and the installation.

Request a review of the boiler. · Consult maintenance

Before requesting a repair

Does the code identify the spare part I need to buy?

No. A single warning can have multiple causes. The spare part reference requires identifying the appliance and confirming the fault; the code or a generic photograph is not sufficient.

Can it be reset again if the fault returns?

It is not advisable to chain resets. Follow only what is outlined for the user in your version's manual. A persistent or recurring lockout requires inspection.

When does it make sense to compare a new boiler?

When you have a diagnosis and a budget, compare repair, availability of the spare part, and replacement according to your installation. An isolated fault code does not justify changing the equipment.

See new boilers · Consult installation or replacement

The technical sheet of each product provides information on its price and availability. Installation is quoted separately depending on the case.

Documentation and other guides

Official manual for Ferroli Bluehelix Hitech RRT C · 3541V300 · Rev. 00 · 02/2021. The page references in the table correspond to the PDF viewer, whose numbering may differ from the printed version.

Consult fault guides by brand and model. · Return to the blog

De la lectura a la acción

What do you need next?