Chamber + Heat exchanger Vaillant VMW 346/5-5 (Giannoni GM30-45-008-10) Ref. GM30-45-008-10
RefurbishedVaillantCombustion chambersGiannoni

Chamber + Heat exchanger Vaillant VMW 346/5-5 (Giannoni GM30-45-008-10) Ref. GM30-45-008-10

Stock · 1 unit

Combustion chamber assembly with primary condensing heat exchanger for Vaillant ecoTEC plus 30–34 kW (e.g., VMW ES 346/5‑5). Giannoni core GM30‑45‑008‑10. Its function is to transfer heat from the burner to the water circuit and condense the flue gases, which is key for the performance and thermal safety of the boiler.

VAT included

Compatibility

Vaillant boilers compatible with reference GM30-45-008-10

Combustion chambers with reference GM30-45-008-10. Four confirmed compatibilities: VMW ES 346/5-5 (R4/R5) and VM ES 306/5-5 (equivalent to VU 306/5-5).

Proven compatibility

Boiler modelFamilyVerification
Vaillant VMW ES 346/5-5 (R4/R5)ecoTEC plus (combi)Contrasted
Vaillant VM ES 306/5-5 (equivalent VU 306/5-5)ecoTEC plus (heating only)Contrasted
Vaillant VSC 306/2-C 200ecoCOMPACTContrasted
Vaillant VK 306ecoVIT plus (floor, heating only)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the reference GM30-45-008-10 is the part for your boiler.

What determines it is not the boiler model, but the reference printed on the part you already have installed.

Diagnosis and fault codes

Symptoms and faults that the GM30-45-008-10 combustion chambers solve.

Common symptoms and faults

  • 01

    Stops due to overheating after a few minutes of demand

    Cause: Primary heat exchanger partially obstructed by scale/sludge

    Check the ΔT supply/return (>35 K) and rapid gradient; inspect the filter/return and the core if the rest is correct.

  • 02

    Boiling/cavitation noise on startup

    Cause: Hot spots due to poor thermal transfer in the primary.

    Check bleeding P.0, service pressure, and presence of sludge; if it persists, consider descaling or replacement of the core.

  • 03

    Condensate drain leak with iron smell/trace

    Cause: Internal leak of the heat exchanger to the condensation chamber

    Visual inspection of the base and collector joints; hydraulic tightness test of the core outside the boiler.

  • 04

    Recurring fault codes F.23/F.24 even after cleaning the installation.

    Cause: Reduced useful section in water channels of the heat exchanger

    Measure temperature drop and check pump flow; if normal, the problem is with the heat exchanger.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.20Safety disconnection due to temperature limiter (STB)Overheating due to poor heat transfer or obstruction in the heat exchanger. Check bleeding, NTC, circulation, and condition of the core; replace if there is scaling/blocked sections.
F.22Lack of water / insufficient pressureIt can occur if there is a micro-leak in the heat exchanger or after bleeding. Reset the pressure, bleed, and check the tightness of the primary; rule out internal leakage of the core.
F.23Excessive temperature variation between supply and returnTypical of reduced flow in the primary or insufficient flow rate. Check the pump/filter and, if it persists with a clean installation, check the thermal drop of the heat exchanger and replace it if it is clogged.
F.24Too rapid temperature increase (insufficient circulation)If the pump and the installation are correct, a partially blocked primary accelerates the temperature rise. Measure the gradient and ΔT; replace the core if the restriction is confirmed.
F.25Combustion gas temperature too highPoor transfer or obstructed fins/smoke can raise the flue gas temperature. Check the flue gas path and clean the body; if the problem is with the core, replace it.
F.28/F.29Ignition failure / flame loss in serviceThese are not typical faults of the primary system, but a siphon/condensate blockage in the combustion chamber or condensate return can contribute. Check the condensate drainage and the tightness of the chamber before ruling out the heat exchanger.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the combustion chambers Vaillant GM30-45-008-10

Catalogue reference
GM30-45-008-10
Brand
Vaillant
Type of part
Combustion chambers
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

manufacturer_component
Giannoni
marked_on_board
GM30-45-008-10
type
Combustion chamber with primary condensing heat exchanger
vaillant_application
ecoTEC plus 30–34 kW (e.g., VMW ES 346/5‑5; VM ES 306/5‑5; ecoCOMPACT VSC 306; ecoVIT VK 306) according to series
refs_vaillant_equivalents
0020135133 (replaces 0020018183) / 0020209546 (according to series and supply of sensors)
state
Refurbished (cleaning, leak testing, and heat exchanger surface inspection)
Before purchasing
  • Cut off gas and electrical supply before intervening.
  • Empty the primary circuit and then bleed (program P.0) until all the air is removed.
  • Always use new gaskets and screws when assembling the heat exchanger (the gaskets are single-use).
  • Check combustion and CO₂ with analyzer after the change; adjust if necessary according to the manual.
  • Check and clean the siphon/condensate drain to prevent returns to the chamber.
  • Respect the torque specifications indicated by the manufacturer on flanges/collectors (consult the installation manual for the specific model).
  • Confirm if your series requires a version with/without associated sensor (different OEM references).
Frequently Asked Questions

Frequently asked questions about the GM30-45-008-10 combustion chambers.

Is it compatible with my Vaillant ecoTEC plus VMW ES 346/5‑5?
Yes, this core GM30‑45‑008 (Giannoni) is used in ecoTEC plus 30–34 kW, including the VMW ES 346/5‑5. Check the marking on your part and the OEM reference from Vaillant (usually 0020135133; in some series 0020209546).
What faults is this heat exchanger involved in?
Obstruction or leak in the primary circuit causes F.20 (overtemperature), F.23/F.24 (circulation/ΔT anomalies) and, due to poor transfer, can raise the flue gas temperature (F.25).
Do I need the version with a sensor?
Some series include specific sensor/supports. Cross-reference your boiler's reference with the official parts list to choose 0020135133 (or its predecessor 0020018183) or the variant 0020209546 as appropriate.
What else should I change when replacing it?
It is mandatory to replace the gaskets and screws of the assembly; it is advisable to clean the circuit, renew the inhibitor, and check the condensate siphon. After assembly, bleed and check the combustion.
Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model