Hydraulic Connection Hoses for Boiler Ciao 24 CSI, Mynute J 24/28 CSI
If you notice leaks, loss of pressure, or problems with the production of hot water, a technical diagnosis must confirm if you need the hydraulic connection hoses for the Ciao 24 CSI and Mynute J 24/28 CSI boilers. This part is responsible for conducting and distributing water between the circuits of the boiler. It is installed in models such as Ciao 24 CSI, Green 25 CSI, Junior 24 CSI, and Mynute J 24 CSI and J 28 CSI, among others. A technician must confirm through diagnosis if it needs to be replaced when signs of wear or faults in the hydraulic system are present.
- Type of part
- Hydraulic units
- Status
- Refurbished
- internal SKU
- LCCBTT28
- Warranty
- 1 year
Compatible Beretta boilers
Hydraulic group. Five confirmed compatibilities: 24 CSI and GREEN 25 CSI.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Beretta 24 CSI | CIAO | Contrasted |
| Beretta GREEN 25 CSI | CIAO | Contrasted |
| Beretta 24 CSI | JUNIOR | Contrasted |
| Beretta J 24 CSI | MYNUTE | Contrasted |
| Beretta J 28 CSI | MYNUTE | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the hydraulic group
The hydraulic group includes the valve, the by-pass, and the water connections. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
Water or moisture appears at the base of the boiler, near the connections.
Cause: The flexible hose has lost flexibility or the fitting is not sealing properly and is slowly leaking water.
Dry the area thoroughly and check again after the boiler has been running for a while to locate the exact point of the leak before replacing the flexible hose.
- 02
The material of the tube appears cracked, soft, or brittle to the touch.
Cause: Heat and age harden corrugated plastic until it loses elasticity and cracks.
Gently bend the flexible hose at a less visible point to check if it gives or cracks.
- 03
The boiler loses pressure over time even though no water is visible.
Cause: A hydraulic connection that doesn't seal completely can leak so slightly that it evaporates without leaving a trace.
Check the pressure gauge after refilling and check again the next day to see if the pressure drops without visible leaks.
- 04
Rust or limescale buildup is noticeable around a fitting.
Cause: A small, constant drip leaves a mineral trace even if the water doesn't accumulate.
Clean the area and carefully tighten the fitting before assuming the flexible hose is broken.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Beretta hydraulic group datasheet
- Uniclima internal SKU
- LCCBTT28
- Brand
- Beretta
- Type of part
- Hydraulic units
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
- The current catalog does not include a reference for this part.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Beretta J 24 CSI Manual (PDF) Document © Beretta, provided as a technical reference.