PCB With LCD Screen Saunier Duval/Hermann Thema Condens F25, Ref. 0010028087
- For 12 Saunier Duval boilers Thema Condens and Themafast Condens
- Check for: The screen does not turn on and the boiler shows no signs of operation., The buttons or the remote control do not respond, even though the screen is on.
- Delivery to the EU in 2–6 working days · Depending on the country; cost shown at checkout
- Returns not accepted (electronic board)
- Inspected and tested, warranty 1 year
Is it compatible with your boiler?
Saunier Duval boilers compatible with reference 0010028087
- F25Thema Condens
- F25 A1Thema Condens
- AS 25 AThema Condens
- 25-AThema Condens
- 25-A R2Thema Condens
- 30-AThema Condens
- F25Themafast Condens
- F30 A1Themafast Condens
- 25-AThemafast Condens
- 30-AThemafast Condens
- F25Semia Condens
- Micra Plus Condens 25Hermann
Can’t see your model? The printed reference takes priority. How to check it or send us a photo on WhatsApp.
How to check if Ref. 0010028087 is the spare part for your boiler
-
Read the reference on your PCB
It must show 0 010 028 087 on the label or the screen print. If it is not legible, do not work it out from its shape.
-
Find the model of your boiler
It is on the rating plate. Look it up in the compatible list.
-
Compare label, PCB and board version
With the installed board, before fitting.
-
If you are unsure, send us a photo
For the screen print: we will confirm it with you before you buy.
Send photo via WhatsApp
Symptoms that require diagnosis on this spare part (electronic board 0010028087)
The screen does not turn on and the boiler shows no signs of operation.
- Cause
- The display and the control electronics are integrated, so a fault can affect both. View error codes F.63, F.64, F.65 and F.67
- What to do
- Check if the boiler ignites the burner or operates the pump; if there are no signs, the fault is likely in the entire PCB.
The buttons or the remote control do not respond, even though the screen is on.
- Cause
- The circuit that processes the pulses has stopped working.
- What to do
- Reset the boiler by cutting the power for 30 seconds; if the buttons still do not respond when turning it back on, there is a fault in the PCB.
The temperature cannot be adjusted from the display, the changes are not saved.
- Cause
- The control circuit for the setpoint does not respond to the commands from the display.
- What to do
- Check if the temperature returns to the same default value after each change attempt; that indicates a fault in the PCB.
The fault codes do not appear on the screen when the boiler is locked.
- Cause
- The display is not receiving or processing the information from the control board correctly. View error codes F.63, F.64, F.65 and F.67
- What to do
- Note when the boiler locks, whether it is when turning on or when requesting hot water; this information helps to confirm if the fault is with the display or another part.
Any work must be carried out by qualified professionals in gas and electricity. Repair and diagnosis
Error codes for Saunier Duval that require diagnosis
Error F.63: EEPROM fault.
- Technical checks
- The EEPROM memory of the main PCB is damaged/corrupted; if NTCs and wiring are correct, the cause is the PCB. Check voltages and, if it persists, reprogram/replace the PCB.
Error F.64: Fault in the electronics / NTC.
- Technical checks
- If the NTC sensors and their wiring do not present shorts or inversion, the fault is in the PCB electronics (measurement/processing stage). Check NTCs and continuity; if okay, replace the PCB.
Error F.65: Fault: electronics temperature.
- Technical checks
- The PCB detects overheating or its internal sensor/power stage is faulty. Check ventilation/temperature and dissipation; if everything is correct, the cause is the PCB.
Error F.67: Fault: electronics/flame.
- Technical checks
- The flame detection/control circuit on the PCB is not plausible or defective. Check the ionisation signal and grounding; if they are correct, replace the PCB.
Error F.70: Invalid product code (DSN).
- Technical checks
- After replacing the display and PCB without readjusting the DSN or with incorrect coding resistance, the PCB locks the equipment. Verify/adjust DSN and resistance; if not accepted, incorrect/defective PCB.
Error F.32: Fault: fan.
- Technical checks
- When the motor and wiring are fine, the fault may be with the PCB (multiple connector on PCB, output/driver, or PWM control). Check the power/signal from the PCB to the fan; if there is no correct output, replace the PCB.
Technical sheet: electronic board Saunier Duval 0010028087
The control PCB governs the ignition, burner modulation, pump, and safety features of the boiler. If it fails, the boiler may not start, lock out, or behave erratically, which can lead to faults such as F.63, F.64, or F.70. This PCB with an LCD screen is compatible with models from Saunier Duval and Hermann, including the Thema Condens F25, F25 A1, and AS 25 A, among others. The confirmed manufacturer reference is 0010028087. A technician must confirm through diagnosis whether it needs to be replaced when the mentioned symptoms occur.
Spare part details
- Saunier Duval reference
- 0010028087
- Silkscreened code on PCB
- AJCP594V-0
Check the label, PCB and revision codes against the installed spare part: they are not necessarily equivalent references. Manual © Saunier Duval, provided as a technical reference. Technical sheet reviewed on .
Frequently asked questions about the spare part electronic board Saunier Duval 0010028087
What code is printed on the PCB with LCD screen of the Thema Condens F25?
AJCP594V-0, screen printed next to the display.
Is Ref. 0010028087 the correct reference for this PCB?
Yes, it corresponds to the reference 0010028087, confirmed by external sources.
Does this PCB work for a Thema Condens boiler?
Yes, it is compatible with the models F25, F25 A1, AS 25 A, 25-A, 25-A R2, and 30-A from the Thema Condens range.
When should this PCB be replaced in the Thema Condens F30?
The technical diagnosis must confirm that it is necessary to replace it, even when the display does not turn on, remains blank, or the controls stop responding.
How many models are compatible with this PCB?
The PCB is compatible with a total of 12 models from the mentioned ranges.
What is the reference for this PCB?
To confirm compatibility, check the manufacturer's reference and the exact model of the equipment.
How do I know if this spare part (PCB) 0010028087 is the right one for my Saunier Duval boiler?
Look at the reference printed on the installed spare part (PCB): it should read 0 010 028 087. Then check the model on your boiler’s rating plate. This spare part (PCB) has 12 verified compatibilities, in the families Thema Condens, Themafast Condens, Semia Condens and Hermann. If you cannot find the reference or your model is not on the list, send us a photo via WhatsApp and we will confirm it before you buy.
What does it mean that this spare part (PCB) is reconditioned?
That it is not a new spare part: it is sold inspected and tested, with a 1-year warranty. As it is an electronic component prepared for a specific boiler model, returns are not accepted.
How much does shipping cost and how long does it take to arrive?
TIPSA shipping: 24/48 working hours to mainland Spain and 2–6 working days to the EU, depending on the country. No shipping to the Balearic or Canary Islands, Ceuta or Melilla.
The exact cost appears in your cart before you pay. Check delivery times and shipping rates by country.
Can I return it if it turns out not to be the right spare part for me?
No. Returns are not accepted for electronic boards: each one is inspected, tested and prepared for a specific boiler model, and the law treats these products as personalised, with no right of withdrawal (article 103 c of the Real Decreto Legislativo 1/2007). Furthermore, once connected it is not possible to check whether it has suffered damage, so it cannot be bought to test whether the fault lies in the board.
If it arrives faulty or we send you a different reference from the one you ordered, we will take responsibility, and this spare part PCB has a 1-year warranty. Before you buy, send us a photo of the label on your spare part PCB via WhatsApp and we will confirm that it is the right one for you. Read the returns policy.