Saunier Duval Isofast F 35 E H MOD SYMSI 7.0 Control PCB Ref. S10470
Control board SYMSI7.0 for the wide range of Saunier Duval boilers Isofast, Isotwin, Themaclassic, Themafast, and Thematek (see compatible models). It is engraved with the code 0310144400S20 and the service label S1047000, very close to the catalog reference S10470. It features Omron relays and a UL certified printed circuit board laminate GF201 94V-0.
Saunier Duval boilers compatible with reference S10470
PCB with reference S10470. 33 verified compatibilities: F 25 E and F 24 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 25 E | ThemaClassic | Contrasted |
| Saunier Duval F 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 25 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 30 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | Themafast | Contrasted |
| Saunier Duval C 25 E | Themafast | Contrasted |
| Saunier Duval C 28 E | Themafast | Contrasted |
| Saunier Duval C 30 E | Themafast | Contrasted |
| Saunier Duval F 24 E | Themafast | Contrasted |
| Saunier Duval F 25 E | Themafast | Contrasted |
| Saunier Duval F 25 E H-MOD | Themafast | Contrasted |
| Saunier Duval F 30 E | Themafast | Contrasted |
| Saunier Duval F 30 E H-MOD | Themafast | Contrasted |
| Saunier Duval C 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EO BT | Thematek | Contrasted |
| Saunier Duval F 24 E | Thematek | Contrasted |
| Saunier Duval S C 24 E | Thematek | Contrasted |
| Saunier Duval S F 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EA | Isotwin | Contrasted |
| Saunier Duval C 28 EA | Isotwin | Contrasted |
| Saunier Duval C 24 E ad04 | Isotwin | Contrasted |
| Saunier Duval C 24 E de04 | Isotwin | Contrasted |
| Saunier Duval F 24 E | Isotwin | Contrasted |
| Saunier Duval F 24 EA | Isotwin | Contrasted |
| Saunier Duval F 28 EA | Isotwin | Contrasted |
| Saunier Duval F 30 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 35 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 25 E STL | Thema | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S10470 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S10470. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB S10470 resolves
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not respond when pressing the reset button.
Cause: The PCB is not supplying power correctly to the control system.
Check the fuse on the PCB and verify that it receives 230V before replacing it.
- 02
There is no spark or flame, although the fan is working.
Cause: The PCB does not send the ignition signal to the electrode, although the fan and the pressure switch are operational.
Check the wiring of the ignition electrode and make sure it has continuity before replacing the PCB.
- 03
The flame goes out after a few seconds and tries to ignite again.
Cause: There is a fault in the circuit of the PCB that controls the flame ionization signal.
Check the grounding connection of the boiler, as a poor contact can cause this issue.
- 04
The hot water comes out with an unstable temperature, fluctuating for no reason.
Cause: The PCB does not correctly manage the signal from the domestic hot water NTC sensor.
Make sure that the water flow is constant and that the inlet filter is clean.
- 05
A communication error with the remote control or the display appears.
Cause: There is a fault in the communication bus between the PCB and the user interface.
Check the two-wire bus wiring between the PCB and the control before replacing the electronics.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F13 | Main PCB fault | Yes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB. |
| F11 | No signal is reaching the main circuit | Possible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB. |
| F12 | No signal from the user interface | Normally not — it's usually the display or its cable, not this main PCB. |
| F18 | User interface fault | Normally not — it corresponds to the panel/display, not to this PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S10470 PCB.
- Catalogue reference
- S10470
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 0 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Control platform (screen printing)
- SYMSI7.0
- Code recorded on PCB
- 0310144400S20
- Service code (white label)
- S1047000
- Batch / traceability
- 902123 / 443953 / 859118T8 / IND 06 / S0097 / KWD
- Relay manufacturer
- Omron (marked on the 3 large relays: REL101H, REL102YC, REL1032D)
- Certification of the PCB laminate
- GF201 94V-0 / GF P/N 2036288E
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval F 35 E H-MOD Manual (PDF)Document © Saunier Duval, provided as a technical reference.