Control Module SYMSI7.0 Vaillant Group Saunier Duval Isofast C 35 EA Ref. S10470
When you open the tap or turn on the heating, the SYMSI7.0 control module from Vaillant Group Saunier Duval Isofast C 35 EA is responsible for controlling the ignition, the modulation of the burner, and the operation of the pump. If this PCB fails, the boiler may not start, become locked, or operate erratically, displaying fault codes such as F13, F11, F12, or F18. This module is compatible with several boilers from the ThemaClassic, Themafast, Thematek, Isotwin, and Isofast ranges, among others. It is recommended to replace it when it shows recurring faults or malfunctioning.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S10470
PCB with reference S10470. 33 verified compatibilities: F 25 E and F 24 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 25 E | ThemaClassic | Contrasted |
| Saunier Duval F 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 25 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 30 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | Themafast | Contrasted |
| Saunier Duval C 25 E | Themafast | Contrasted |
| Saunier Duval C 28 E | Themafast | Contrasted |
| Saunier Duval C 30 E | Themafast | Contrasted |
| Saunier Duval F 24 E | Themafast | Contrasted |
| Saunier Duval F 25 E | Themafast | Contrasted |
| Saunier Duval F 25 E H-MOD | Themafast | Contrasted |
| Saunier Duval F 30 E | Themafast | Contrasted |
| Saunier Duval F 30 E H-MOD | Themafast | Contrasted |
| Saunier Duval C 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EO BT | Thematek | Contrasted |
| Saunier Duval F 24 E | Thematek | Contrasted |
| Saunier Duval S C 24 E | Thematek | Contrasted |
| Saunier Duval S F 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EA | Isotwin | Contrasted |
| Saunier Duval C 28 EA | Isotwin | Contrasted |
| Saunier Duval C 24 E ad04 | Isotwin | Contrasted |
| Saunier Duval C 24 E de04 | Isotwin | Contrasted |
| Saunier Duval F 24 E | Isotwin | Contrasted |
| Saunier Duval F 24 EA | Isotwin | Contrasted |
| Saunier Duval F 28 EA | Isotwin | Contrasted |
| Saunier Duval F 30 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 35 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 25 E STL | Thema | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S10470 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S10470. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB S10470 resolves
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The control module screen is off or not displaying anything, even though the boiler is powered.
Cause: The control module does not power the display, preventing it from turning on.
Make sure that the connector between the control module and the boiler is properly fitted and without bent pins before replacing it.
- 02
The buttons on the panel do not respond or respond with a delay.
Cause: The electronics that control the buttons of the module are not functioning properly.
Clean the connector contact and reset the boiler; if the problem persists with different buttons, the fault is in the module.
- 03
The boiler does not modulate the power: it always provides maximum or minimum, with no intermediate settings.
Cause: The control module does not properly manage the modulation signal of the burner.
Measure if the problem occurs the same in heating as in domestic hot water; if it only happens in one function, first check the sensor for that function.
- 04
An internal communication fault code appears that does not clear upon reset.
Cause: The module detects a problem in its internal communication and locks itself for safety.
Note the exact code: in these systems, there is a distinction between internal communication failure and failure of a specific external component.
- 05
The boiler starts up well but disconnects a few seconds after starting.
Cause: One of the relays in the module does not keep the contact closed for the necessary time.
Check if the cut occurs at the same time after ignition; a repetitive pattern suggests a problem with a relay rather than a gas fault.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F13 | Main PCB fault | Yes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB. |
| F11 | No signal is reaching the main circuit | Possible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB. |
| F12 | No signal from the user interface | Normally not — it's usually the display or its cable, not this main PCB. |
| F18 | User interface fault | Normally not — it corresponds to the panel/display, not to this PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S10470 PCB.
- Catalogue reference
- S10470
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- PCB model
- SYMSI7.0
- PCB code
- 0310144400S20
- Service label
- 902123 / S1047000 / 443953 / 859118T8 / KWD IND06 S0097
- Mounted relays
- 3x Omron
- UL certification
- GF201, classification 94V-0
- Reference GF (P/N)
- 2036288E
- This unit carries the red "REPARATION" seal: it is a refurbished PCB, not new. Check it if you are looking for a brand new unit.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval F 35 E H-MOD Manual (PDF)Document © Saunier Duval, provided as a technical reference.