Saunier Duval Themafast C 24 E Display Module Ref. S1017200

Saunier Duval Themafast C 24 E Display Module Ref. S1017200

Stock · 1 unit

Saunier Duval Themafast includes the display module that controls the ignition, the modulation of the burner, the pump, and the safety features of the boiler. When this PCB (control board) fails, the boiler may not start, become locked, or exhibit erratic operation, potentially displaying fault codes such as F13, F11, F12, or F18. It is compatible with models such as Themafast C 24 E and Themafast F 24 E, among others. It is recommended to replace it upon detecting issues in the operation of the boiler.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S1017200

PCB with reference S1017200. Two confirmed compatibilities: Themafast C 24 E and Themafast F 24 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Themafast C 24 EThemafastContrasted
Saunier Duval Themafast F 24 EThemafastContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part S1017200 is the one for your boiler.

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1017200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB S1017200 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler display does not turn on or remains blank, although the boiler seems to be functioning internally.

    Cause: The display module manages the visualization, and if it loses power or communication with the main PCB, it does not show anything.

    Check that the flat connector joining the module to the PCB is properly seated and does not have any oxidized or bent pins.

  • 02

    The plus, minus, or hand/reset buttons do not respond when pressed.

    Cause: The micro switch of that button on the module has worn out or has stopped transmitting the press.

    Press each key several times, observing if anything changes on the screen, to determine if a specific key is faulty or if the entire module is malfunctioning.

  • 03

    The screen shows stripes, loose symbols, or some digits that do not light up.

    Cause: The module panel or its internal connection is damaged and no longer accurately represents what the PCB sends it.

    Note which symbols are failing exactly and compare them with the manual; sometimes it is a fault code that is displayed incorrectly and not a fault of the module.

  • 04

    The boiler cannot be reset from the panel because the manual/reset button does nothing.

    Cause: That button sends the reset command to the control board, and if the module fails, the command never arrives.

    First, confirm that the boiler is actually locked with a visible fault code before assuming that the reset does not work.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F13Main PCB faultYes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB.
F11No signal is reaching the main circuitPossible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB.
F12No signal from the user interfaceNormally not — it's usually the display or its cable, not this main PCB.
F18User interface faultNormally not — it corresponds to the panel/display, not to this PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S1017200 PCB.

Catalogue reference
S1017200
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB S1017200

Is this module compatible with the Themafast C 24 E?
Yes, the Saunier Duval Themafast C 24 E display module Ref. S1017200 is compatible with the Themafast C 24 E.
Does this module work with the Themafast F 24 E?
Yes, it is also compatible with the Themafast F 24 E.
How many models are compatible with this module?
The module is compatible with a total of 2 models: Themafast C 24 E and Themafast F 24 E.
What fault codes are compatible with this module?
The documented fault codes for this module are F13, F11, F12, and F18.
What is the reference for this module?
The reference for the display module is MDTC24E.
Can I use this module in boilers that are not from the Themafast range?
No, this module is only compatible with the models from the Themafast range mentioned.

Spare parts related to Saunier Duval Themafast

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Themafast C 24 E Display Module Ref. S1017200