Saunier Duval Twin 0-4 Bar Pressure Gauge Ref. 05600500

Saunier Duval Twin 0-4 Bar Pressure Gauge Ref. 05600500

15 €VAT includedIn stock · 1 unit

White dial capillary pressure gauge with a graduated scale from 0 to 4 bar and a metal connection fitting, with no visible manufacturer brand after enlarging the photo. It indicates the water pressure of the heating circuit in THELIA 30 E, MASTER TWIN L 85 E, THELIA TWIN 28 E, and TWIN F 28 E boilers. It is replaced when the needle does not indicate pressure or the capillary is damaged.

Spare parts related to Saunier Duval TWIN

Compatibility

Saunier Duval boilers compatible with reference 05600500

Pressure gauge with reference 05600500. 11 confirmed compatibilities with two independent sources: TWIN F 24 E and TWIN F 28 E. Verify the printed reference on your part before purchasing.

Compatibility confirmed

Boiler modelFamilyVerification
Saunier Duval TWIN F 24 ETWINConfirmed · 2 sources
Saunier Duval TWIN F 28 ETWINConfirmed · 2 sources
Saunier Duval TWIN C 24 ETWINConfirmed · 2 sources
Saunier Duval TWIN C 28 ETWINConfirmed · 2 sources
Saunier Duval MASTER TWIN L 85 ETWINConfirmed · 2 sources
Saunier Duval THELIA TWIN 28 ETHELIA TWINConfirmed · 2 sources
Saunier Duval THEMIS TWIN 28 ETHEMIS TWINConfirmed · 2 sources
Saunier Duval THEMIS TWIN 28 EVTHEMIS TWINConfirmed · 2 sources
Saunier Duval SYLVA 24 ESYLVAConfirmed · 2 sources
Saunier Duval SYLVA 24 EVSYLVAConfirmed · 2 sources
Saunier Duval SYLVA FF 24 ESYLVAConfirmed · 2 sources

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 05600500 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Locate the reference printed on the body of the pressure gauge you have installed: it should indicate 05600500.
  2. Check your boiler model on the nameplate and look for it in the list of compatible models on this page.
  3. Compare the connections and the body with the original part before installing.
  4. If you have any doubts, send us a photo of the screen printing via WhatsApp and we'll confirm it for you before you purchase.
Diagnosis

Symptoms and faults resolved by pressure gauge 05600500

The pressure gauge shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

The needle does not move from zero even though the boiler is loaded and running.

Cause: The capillary that carries the pressure from the circuit to the gauge is blocked or the mechanism is seized.

Follow the path of the capillary tube looking for any bends or crushing before considering the manometer as faulty.

The thin tube coming from the pressure gauge is bent, crushed, or broken.

Cause: The capillary is the only path through which the pressure signal arrives; if it gets pinched or breaks, the gauge stops receiving information even if the rest of the circuit is fine.

Check if the capillary tube got trapped between sheets or cables when assembling or disassembling the boiler casing.

Water or moisture appears at the fitting where the capillary joins the circuit.

Cause: The gasket of that fitting has degraded and is allowing water to pass through at low pressure.

Tighten the fitting carefully, dry the area, and check if it becomes damp again before replacing the part.

The dial is broken or so scratched that the needle is indistinguishable.

Cause: A previous handling impact has damaged the watch's crystal or body.

Check that the damage is only cosmetic on the glass, without affecting the capillary, before replacing the entire assembly.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval pressure gauge 05600500

OEM reference
05600500
Brand
Saunier Duval
Type of part
Pressure gauges - Aquastats
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Pressure range
0-4 bar
label
Type of pressure gauge
Capillary, with metal connection fitting
label
Dial color
White
label
Before purchasing
  • The manufacturer of the part is not indicated; the metal fitting of the capillary does not show any visible brand even after enlarging the photo x6.
  • There is no readable reference code on the photographed part.
  • The reference shown in today's catalog (05600500) is not confirmed on the label or by external sources; please verify it before ordering the part.
  • It has not been possible to cross-reference this part with external sources in this review; additional information not consulted cannot be ruled out.
Frequently Asked Questions

Frequently Asked Questions about Pressure Gauge 05600500

Is this capillary pressure gauge suitable for the THELIA 30 E boiler?
Yes, it is indicated as compatible with the THELIA 30 E, as well as with the MASTER TWIN L 85 E, THELIA TWIN 28 E, and TWIN F 28 E.
Which manufacturer makes this capillary pressure gauge for the MASTER TWIN L 85 E?
There is no visible manufacturer brand on the piece, not even after enlarging the photo.
Does the pressure gauge of the TWIN F 28 E have a capillary tube?
Yes, this model includes a capillary tube and a metal connection fitting, according to the photo of the part.
When should the capillary pressure gauge of the THELIA TWIN 28 E be replaced?
When the needle does not indicate pressure or the capillary is damaged.
What pressure does the gauge of reference 05600500 indicate?
Scale from 0 to 4 bar, according to the white graduated dial of the piece.
Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model