Pressure Gauge Vaillant VMW / VMI Ref. 101271
Pressure gauge for Vaillant boilers VM 240-5, VM 282-5, VMI 280-7, VMW 28/362-5, VU 200, VU 240-5, VUW 240/5, and VUW 282-5. It indicates the pressure of the heating circuit; scale from 0 to 3 bar, with a green zone up to approximately 1.8 bar and a red mark at 3 bar. The available photo is of the rear view, with no visible dial or legible text, so the manufacturer of the part is not specified.
Spare parts related to Vaillant Turbotec / Turboblock (VMW)
Vaillant boilers compatible with reference 101271
Manometer with reference 101271. 21 confirmed compatibilities with two independent sources: VMW 24/282-5 R2 and VMW 24/282-5 R1. Verify the printed reference on your part before purchasing.
Compatibility confirmed
| Boiler model | Family | Verification |
|---|---|---|
| Vaillant VMW 24/282-5 R2 | Turbotec / Turboblock (VMW) | Confirmed · 2 sources |
| Vaillant VMW 24/282-5 R1 | Turbotec / Turboblock (VMW) | Confirmed · 2 sources |
| Vaillant VMW 242/2-5 | Turbotec / Turboblock (VMW) | Confirmed · 2 sources |
| Vaillant VMW 282-5 | Turbotec / Turboblock (VMW) | Confirmed · 2 sources |
| Vaillant VMW 282/2-5 | Turbotec / Turboblock (VMW) | Confirmed · 2 sources |
| Vaillant VMW 202-5 | Turbotec / Turboblock (VMW) | Confirmed · 2 sources |
| Vaillant VMW 24/280-5 | Turbotec / Turboblock (VMW) | Confirmed · 2 sources |
| Vaillant VMW 240-5 | Atmotec / Atmoblock (VMW) | Confirmed · 2 sources |
| Vaillant VMW 280-5 | Atmotec / Atmoblock (VMW) | Confirmed · 2 sources |
| Vaillant VMW 242-5 | Atmotec / Atmoblock (VMW) | Confirmed · 2 sources |
| Vaillant VM 242-5 | VM (heating) Turboblock/Ecoblock | Confirmed · 2 sources |
| Vaillant VM 282-5 | VM (heating) Turboblock/Ecoblock | Confirmed · 2 sources |
| Vaillant VM 202-5 | VM (heating) Turboblock/Ecoblock | Confirmed · 2 sources |
| Vaillant VM 240-5 | VM (heating) Turboblock/Ecoblock | Confirmed · 2 sources |
| Vaillant VM 280-5 | VM (heating) Turboblock/Ecoblock | Confirmed · 2 sources |
| Vaillant VMI 280-7 | VMI (Acquablock) | Confirmed · 2 sources |
| Vaillant VMI 282-7 | VMI (Acquablock) | Confirmed · 2 sources |
| Vaillant VMI 240-7 | VMI (Acquablock) | Confirmed · 2 sources |
| Vaillant VMI 242-7 | VMI (Acquablock) | Confirmed · 2 sources |
| Vaillant VKC I 322/1-3 | VKC (Atmovit/Turbovit Combi) | Confirmed · 2 sources |
| Vaillant VKC I 320/1-3 | VKC (Atmovit/Turbovit Combi) | Confirmed · 2 sources |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 101271 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Locate the reference printed on the body of the pressure gauge you have installed: it should indicate 101271.
- Check your boiler model on the nameplate and look for it in the list of compatible models on this page.
- Compare the connections and the body with the original part before installing.
- If you have any doubts, send us a photo of the screen printing via WhatsApp and we'll confirm it for you before you purchase.
Symptoms and faults resolved by pressure gauge 101271
The pressure gauge shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
The needle doesn't move; it always stays at the same point no matter what I do with the installation.
Cause: The internal spring of the pressure gauge gets stuck due to rust or accumulated scale and stops responding to pressure changes.
Bleed a radiator or briefly open the filling valve and see if the needle reacts; if it doesn't move at all, the pressure gauge is suspect.
It indicates a pressure that doesn't match what the rest of the boiler says, for example, the low pressure fault triggers and the pressure gauge shows it's fine.
Cause: The mechanism loses calibration over time, and the reading deviates even though it continues to operate normally.
If the boiler has a digital pressure reading, compare it with the gauge before replacing it.
There is water dripping from the back, either from the fitting or the capillary that goes to the circuit.
Cause: The fitting gasket or the capillary itself degrades with the cycles of heat and pressure and starts to leak.
Dry the area thoroughly and tighten the fitting without forcing it; if the leak reappears in minutes, it's not just a matter of tightening.
The needle is stuck right at the red mark of 3 bar, even though you have bled and lowered the pressure.
Cause: It is common for it to get stuck at the stop if dirt or limescale has entered the mechanism after a temporary overpressure.
Gently tap the sphere with your finger, without applying force, and check if the needle drops; if it doesn't, the blockage is internal.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Vaillant 101271 pressure gauge datasheet
- OEM reference
- 101271
- Brand
- Vaillant
- Type of part
- Pressure gauges - Aquastats
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Pressure gauge
- 0-3 bar, green zone approx. 0-1.8 bar, red mark at 3 bar
label
- This unit does not have legible markings in the available photos: only the rear body and the capillary are visible, without a dial or text.
- The manufacturer of the part is not listed, and no commercial code could be confirmed.
- Check that the scale (0-3 bar, green zone up to approx. 1.8 bar) matches your pressure gauge before ordering it.