Junkers/Bosch Circulating Pump ZWE/ZWR/ZR Grundfos UPS 15-35/50 Ref. 8717204264
RefurbishedJunkersPumpsGrundfos

Junkers/Bosch Circulating Pump ZWE/ZWR/ZR Grundfos UPS 15-35/50 Ref. 8717204264

Stock · 1 unit

Grundfos UPS 15-35/50 JULA circulating pump used in Junkers/Bosch boilers from the ZWE, ZWR, ZR, and MINI-KE31 series. It circulates water through the heating circuit. It is replaced when it stops circulating, makes noise, or leaks water from the shaft. Grundfos code 8717204264, manufacturer P/N 59615536.

VAT included

Compatibility

Junkers boilers compatible with reference 8717204264

Circulating pump with reference 8717204264. 14 verified compatibilities: ZWE 24 and ZWE 24-1 ADE.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZWE 24Eurostar (ZWE 24)Contrasted
Junkers ZWE 24-1 ADEEurostar (ZWE 24)Contrasted
Junkers ZWE 24-2 ADEEurostar (ZWE 24)Contrasted
Junkers ZWE 24-2 KDPEurostar (ZWE 24)Contrasted
Junkers ZWE 24-3 MFADEurostar (ZWE 24)Contrasted
Junkers ZWE 24-3 HKDEurostar (ZWE 24)Contrasted
Junkers ZWR 18-2 KDEZWR (atmospheric mixed)Contrasted
Junkers ZWR 24-2 ADEZWR (atmospheric mixed)Contrasted
Junkers ZR 18-2 KDEZR (atmospheric heating only)Contrasted
Junkers ZE 24-2 KDPZE / Cerastar (ZE 24)Contrasted
Junkers ZE 24-3 MFKDZE / Cerastar (ZE 24)Contrasted
Junkers MINI 11 KEMini / compactContrasted
Junkers ZBR 12ZBR (low condensation)Contrasted
Junkers ZBR 25 AZBR (low condensation)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 8717204264 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 8717204264. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the circulation pump 8717204264 solves.

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler heats up but very slowly, or the radiators don't get fully hot.

    Cause: If the flow moved by the pump is insufficient, the heat is not distributed at the rate required by the installation.

    Check the speed at which the pump is configured and try increasing it before replacing it.

  • 02

    A humming, gurgling, or rattling noise is heard in the pump area.

    Cause: Air trapped in the circuit or a worn bearing prevent the rotor from spinning smoothly and can be noticed as noise.

    Bleed the highest radiator in the system and check if the noise disappears before considering the pump as faulty.

  • 03

    A drip or water stain appears on the casing or near the pump shaft.

    Cause: The mechanical seal wears out over the years and allows a slow leak that is not related to nearby union gaskets.

    Dry the area thoroughly, check after a heating cycle, and confirm that the water is coming from the pump body and not from a nearby joint.

  • 04

    The rotor is blocked and the pump does not start, even though it is receiving power.

    Cause: It is typical after a long period of inactivity at the end of the season, because lime deposits on the shaft and seizes it up.

    With the pump unplugged, try to free the shaft manually with a flat screwdriver through the front slot of the motor before replacing it.

Fault codes from Junkers that this part resolves.

CodeFaultDiagnosis and solution
E9Temperature limiter (STB) activated due to overheating.If the circulating pump is blocked, faulty, or has air, there is no circulation in the primary; the heat exchanger overheats and triggers the STB. Check that the pump is rotating and receiving voltage, and bleed the circuit to remove air pockets.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Junkers 8717204264 circulation pump.

Catalogue reference
8717204264
Brand
Junkers
Type of part
Pumps
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

type (Grundfos)
UPS15-35/50 JULA
Manufacturer P/N
59615536
Grundfos code
8717204264
manufacturing date (FD)
1802JU
voltage
230V~
frequency
50Hz
capacitor
2µF
degree of protection
IP44
maximum fluid temperature (TF)
95°C
insulation class
H
maximum pressure
0.6 MPa
absorbed power (2 speeds)
75 / 80 W
current (2 speeds)
0.34 / 0.36 A
Frequently Asked Questions

Frequently asked questions about the circulator pump 8717204264

How do I distinguish the UPS 15-35/50 JULA pump from the TTAO version for my Junkers ZWE24?
Check that the Grundfos code ends in 264 and states UPS15-35/50 JULA; the version with the code ending in 384 and model TTAO is not this part.
Is this pump suitable for the Junkers ZR18-2 boiler?
Yes, it is compatible with the Junkers/Bosch ZWE, ZWR, ZR, and MINI-KE31 series, including ZR18-2.
What is the manufacturer's P/N for the pump of the ZWE24 series?
59615536.
When should the heating circuit pump of the ZWR18-2 be replaced?
When the water stops circulating, it makes noise or leaks water from the shaft.