Wilo Circulator Pump HB15/6.7-2 Saunier Duval Themafast F 30 E - Ref. S1061800

Wilo Circulator Pump HB15/6.7-2 Saunier Duval Themafast F 30 E - Ref. S1061800

Wilo HB15/6.7-2 circulator pump, manufactured by Wilo, installed in Saunier Duval boilers from the Themafast F25/F30 and Themaplus C23/C25/C30 series and F25/F30. It circulates water through the heating circuit. Replacement requires first confirming the fault of the part through technical diagnosis, even when the boiler is not heating, the radiators remain cold, or the pump is making noise. Its label codes are 4514062 and 4514293; the current catalog reference, S1061800, does not match and appears repeated in another distinct SKU.

Type of part
Pumps
Catalogue reference
S1061800
Warranty
1 year
VAT includedStock · 3 units
Compatibility

Saunier Duval boilers compatible with reference S1061800

Circulating pump with reference S1061800. Four confirmed compatibilities: Themafast F 25 E H-MOD and Themafast F25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Themafast F 25 E H-MODThemafastContrasted
Saunier Duval Themafast F25EThemafastContrasted
Saunier Duval Themafast F 30 E H-MODThemafastContrasted
Saunier Duval Themafast F30EThemafastContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1061800 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1061800. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the circulator pump S1061800

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler turns on and seems to work, but the radiators are cold or just lukewarm.

    Cause: The pump is not circulating water through the heating circuit, so the heat is not reaching the radiators even though the burner is working.

    Check with a screwdriver on the front screw if the shaft turns freely and bleed the air from the circuit before declaring the pump faulty.

  • 02

    A humming or rubbing noise is heard in the pump when starting up.

    Cause: The impeller is rubbing or there is air and scale accumulated in the pump body, which is forcing the motor.

    Bleed the air from the circuit and the pump body itself using the bleed screw before replacing it.

  • 03

    The pump does not start after the summer or a long shutdown.

    Cause: The shaft seizes due to sediment or lime buildup during inactivity.

    Try to manually unlock the shaft with the front screw before considering the pump as faulty.

  • 04

    Water or moisture appears at the base of the pump, near the shaft.

    Cause: The mechanical seal of the shaft has lost its tightness and is allowing water to pass through.

    Dry the area and check if the leak reappears with the boiler running, to rule out that it is moisture from a recent bleed.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
F.23Safety shutdown due to excessive temperature difference (very reduced circulation).If the circulating pump (S1061800) is blocked or not rotating, the flow rate drops: the supply heats up quickly and the return remains cold, triggering F.23. Check the voltage to the pump, consumption/start-up, and actual flow rate (bleeding or test program if applicable).
F.24Safety shutdown due to excessively rapid temperature increase (lack of circulation).A faulty heating pump or one without flow causes a large rise gradient in the supply and triggers F.24. Check that the pump receives 230 V, starts, and that the system is correctly bled.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S1061800 circulation pump.

Catalogue reference
S1061800
Uniclima internal SKU
BHCF30
Brand
Saunier Duval
Type of part
Pumps
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Model
HB15/6.7-2
Printed codes
4514062 / 4514293
Protection rating
IP44
Nominal pressure
PN3
Speeds (rpm)
2500 / 2180
Current (A)
0,38 / 0,29
Power (W)
85 / 64
Condenser
2.6 µF - 400VDB
Voltage/frequency
~230V - 50Hz
Insulation class
F - TF95
Manufacturing date
week 07/2005
Frequently Asked Questions

Frequently asked questions about the S1061800 circulation pump

Is this Wilo HB15/6.7-2 pump compatible with my Saunier Duval Themafast F 30 E H-MOD boiler?
Yes, this pump is compatible with the Themafast range, including the Themafast F 30 E H-MOD model.
What symptoms indicate that I should replace the Wilo HB15/6.7-2 pump in a Themafast F 25 E H-MOD?
The technical diagnosis must confirm whether it is necessary to replace the pump if the boiler is not heating, the radiators remain cold, or if the pump is making unusual noises.
What is the consumption of the Wilo HB15/6.7-2 pump?
The pump operates at two speeds: 0.38 A / 85 W and 0.29 A / 64 W.
How many models are compatible with the Wilo HB15/6.7-2 pump?
This pump is compatible with a total of 4 models from the Themafast range.
What fault codes can indicate a problem with this pump?
The documented fault codes for this pump are F.23 and F.24.
What is the reference for the Wilo HB15/6.7-2 pump?
BHCF30 is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.

Spare parts related to Saunier Duval Themafast

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Wilo Circulator Pump HB15/6.7-2 Saunier Duval Themafast F 30 E - Ref. S1061800