3-Way Motor Valve WGC Divabloc For Saunier Duval Isofast F 35 EA - Code SP 0311763
Three-way valve actuator/motor, identified on the label as Divabloc type and manufactured by WGC. It is installed in the Saunier Duval/De Dietrich Isofast, Isomax, Isosplit, Isotwin, Themafast, and Themaplus range. It is the mechanism that moves the valve between heating and domestic hot water; it is replaced when it stops switching or gets stuck.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S1025500
3-way valve with reference S1025500. 18 verified compatibilities: F 35 E-A and F 30 E-A.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 35 E-A | Isofast | Contrasted |
| Saunier Duval F 30 E-A | Isofast | Contrasted |
| Saunier Duval C 35 E-A | Isofast | Contrasted |
| Saunier Duval F 35 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 30 E H-MOD | Isofast | Contrasted |
| Saunier Duval Condens F 30 E | Isofast | Contrasted |
| Saunier Duval Condens F 35 E | Isofast | Contrasted |
| Saunier Duval F 35 E | Isomax | Contrasted |
| Saunier Duval F 35 H-MOD | Isomax | Contrasted |
| Saunier Duval Condens F 35 E | Isomax | Contrasted |
| Saunier Duval F 30 H-MOD | Isotwin | Contrasted |
| Saunier Duval Condens F 30 E | Isotwin | Contrasted |
| Saunier Duval F 25 E | Themafast | Contrasted |
| Saunier Duval F 30 E | Themafast | Contrasted |
| Saunier Duval C 25 E | Themafast | Contrasted |
| Saunier Duval C 30 E | Themafast | Contrasted |
| Saunier Duval Condens F 25 | Themafast | Contrasted |
| Saunier Duval Condens F 30 | Themafast | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S1025500 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S1025500. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the S1025500 three-way valve resolves.
The 3-way valve diverts water between heating and domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not switch between heating and domestic hot water; it remains stuck in one mode.
Cause: The Divabloc motor does not rotate, so the valve remains fixed.
With the boiler requesting domestic hot water, check if the motor body rotates or vibrates; if it does not move, the fault is in the motor.
- 02
A dry noise or a strange buzzing is heard just when it should switch from heating to domestic hot water, or vice versa.
Cause: The motor gets stuck halfway due to wear and does not fit into its final position.
Check if the noise occurs at the same point in the domestic hot water startup cycle; if so, focus more on the motor.
- 03
There is a lack of domestic hot water while the heating continues to function normally, or conversely, there is a lack of heating while there is hot water.
Cause: The motor has not turned all the way to the stop and the valve has remained serving only one circuit.
Try to move the motor by hand if it has an accessible lever or stop, and check if it turns smoothly.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F.20 | Safety shutdown: temperature limiter. | If the 3-way valve (priority valve) is blocked or disconnected, the primary flow does not switch correctly and the generator overheats, triggering the F.20; to verify, force the test/diagnosis that moves the valve from the service menu and check the power supply/wiring and ensure the shaft/motor are not seized. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval 3-way valve S1025500.
- Catalogue reference
- S1025500
- Brand
- Saunier Duval
- Type of part
- 3-way valves
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Component manufacturer
- WGC (oval logo on label)
- Type of part
- Divabloc
- SP code (manufacturer)
- 0311763
- Plastic material
- PBT (resin code on the label)
- The batch/date code (240I03002 B) has characters that can be confused (1/I, 0/O); do not use it as a purchase reference.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval F 35 E H-MOD Manual (PDF)Document © Saunier Duval, provided as a technical reference.