Right Hydraulic Group Chaffoteaux 3-Way Valve Elexia Comfort 24 FF Ref. 61301936

Right Hydraulic Group Chaffoteaux 3-Way Valve Elexia Comfort 24 FF Ref. 61301936

When you open the tap or turn on the heating, the Chaffoteaux Elexia Comfort 24 FF Right Hydraulic Group 3-Way Valve Ref. 61301936 is responsible for directing the water between the heating circuit and the domestic hot water circuit. If this valve fails, you will notice that you have hot water but no heating, or vice versa, or even that both circuits are mixing. This part is installed in the Elexia Comfort 24 FF boiler, among others. A technician must confirm through diagnosis whether it needs to be replaced if you experience these water distribution issues.

Type of part
Hydraulic units
Catalogue reference
61301936
Warranty
1 year
VAT included OUT OF STOCK
Compatibility

Chaffoteaux boilers compatible with reference 61301936

Hydraulic group with reference 61301936. A proven compatibility: Elexia Comfort 24 FF.

Proven compatibility

Boiler modelFamilyVerification
Chaffoteaux Elexia Comfort 24 FFChaffoteaux Elexia ComfortContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 61301936 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 61301936. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the hydraulic group 61301936

The hydraulic group includes the valve, the by-pass, and the water connections. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    There is no domestic hot water even though the heating works, or vice versa.

    Cause: The valve gets stuck in one position and does not direct the water to the correct circuit.

    Before changing the group, check that the gas valve motor is receiving power when the boiler requests the change and that it is not mechanically stuck.

  • 02

    The water comes out lukewarm or mixed between heating and domestic hot water.

    Cause: The internal shutter does not fully close a passage and allows water to flow into both circuits simultaneously.

    Check that there is no limescale or dirt on the valve seat before replacing the entire hydraulic group.

  • 03

    Water leak from the hydraulic group body

    Cause: The plastic body cracks or the internal seals lose tightness with use.

    Locate the exact point of the leak with the boiler running; if it comes from an accessible joint, consider whether it's enough to replace it rather than the entire assembly.

  • 04

    The boiler makes a knocking or clicking noise when switching from heating to domestic hot water.

    Cause: The internal mechanism of the valve moves with friction or the return spring is worn out.

    Listen to see if the noise occurs exactly when a hot water tap is opened, so you can confirm that the source is the switching and not the pump.

Chaffoteaux fault codes that require diagnosis

CodeFaultTechnical checks
40-50-60-80Distribution valve blocked in heatingThe 3-way valve gets stuck in the heating position and does not switch to domestic hot water; the control detects the incorrect flow diversion and enters a fault. Verify by requesting DHW and observing if the 3-way valve switches (movement of the actuator/rod or position micro) or by powering the motor to check the travel.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Technical sheet: Chaffoteaux 61301936

Catalogue reference
61301936
Uniclima internal SKU
V3VEC24FF
Brand
Chaffoteaux
Type of part
Hydraulic units
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Frequently Asked Questions

Frequently asked questions: hydraulic group 61301936

What exactly is the hydraulic group of the Maya 24 FF?
It is a black plastic hydraulic group with the 3-way valve body integrated.
When should this hydraulic group be replaced in an MC 2 24 CF?
The technical diagnosis must confirm that it is necessary to replace it, even when the boiler does not switch properly between modes, there are leaks in the body, or the water comes out mixed.
Is this hydraulic group suitable for a Maya 28 FF B?
Yes, the Maya 28 FF B is on the list of compatible boilers.

Spare parts related to Chaffoteaux Chaffoteaux Elexia Comfort

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Right Hydraulic Group Chaffoteaux 3-Way Valve Elexia Comfort 24 FF Ref. 61301936