Baxi Victoria Condens - Neobit Condens Display / Control Panel

Baxi Victoria Condens - Neobit Condens Display / Control Panel

Stock · 1 unit

If your boiler does not start, gets blocked, or shows erratic behavior, you may need the Baxi Victoria Condens - Neobit Condens control panel. This PCB (control board) is responsible for regulating the ignition, burner modulation, pump, and safety features of the boiler. It is compatible with the Victoria Condens 24/24 F, Victoria Condens 28/28 F, and Neobit Condens 24/24 F models, among others. It is recommended to replace it when it shows faults in operation or prevents the boiler from starting.

VAT included

Compatibility

Baxi Roca boilers compatible with reference 7648436

PCB with reference 7648436. Three confirmed compatibilities: Victoria Condens 24/24 F and Victoria Condens 28/28 F.

Proven compatibility

Boiler modelFamilyVerification
Baxi Roca Victoria Condens 24/24 FVictoria CondensContrasted
Baxi Roca Victoria Condens 28/28 FVictoria CondensContrasted
Baxi Roca Neobit Condens 24/24 FNeobit CondensContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 7648436 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 7648436. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 7648436 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The screen does not turn on and the rotary controls do nothing, as if the panel were dead.

    Cause: The panel, which includes the display and controls, may have an internal fault that prevents it from functioning properly.

    Check that the boiler is receiving power and that no fuses or the main switch have tripped before considering that the PCB is faulty.

  • 02

    The OFF/MAX rotary controls turn but do not change anything in the boiler.

    Cause: The potentiometer or encoder behind the control may be worn out or dirty, which prevents it from transmitting the position to the electronics.

    Turn the knob several times from end to end and see if it responds at any point; if it does, the knob may be dirty and not completely faulty.

  • 03

    The RESET button does nothing when pressed while the boiler is locked.

    Cause: If the reset button on the panel does not close the contact, the signal to unlock the boiler does not reach the control board.

    Cut the power to the boiler for about 30 seconds and turn it back on; if it unlocks, the problem is with the reset button and not with the original fault.

  • 04

    The icons on the screen appear dim or partially visible, although the panel does respond to the controls.

    Cause: This could be a problem with the LCD itself or its backlighting, which is independent of the control part of the panel.

    Look at the screen from different angles and with the room dark; if the icons appear faint but visible, the problem is more with the LCD than with the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Baxi Roca PCB 7648436

Catalogue reference
7648436
Brand
Baxi Roca
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Type of component
Plastic front panel with OFF/MAX rotary controls, LCD screen, and RESET button (not the rear PCB).
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 7648436

Does this control panel work for the Baxi Victoria Condens 24/24 F?
Yes, it is listed along with Victoria Condens 28/28 F and Neobit Condens 24/24 F.
Is it also suitable for the Baxi Neobit Condens 24/24 F?
Yes, it is one of the three compatible models indicated in the datasheet.
What fault requires changing this control board in the Victoria Condens?
It is replaced when the panel stops turning on, the OFF/MAX rotary controls do not respond, or the RESET button does not work.
Is this just the front panel with the controls?
Yes, it is the front panel with the OFF/MAX controls, the LCD screen, and the RESET button; it does not include other components.
What is the reference for this control panel?
The reference for this control board is DECBVC0501.

Spare parts related to Baxi Roca Victoria Condens

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Baxi Victoria Condens - Neobit Condens Display / Control Panel